Honeywell SERIES COMMUNICATING TB7600 Installation Instructions Manual page 12

Tb7600 series communicating rtu/heat pump thermostats for commercial hvac applications
Hide thumbs Also See for SERIES COMMUNICATING TB7600:
Table of Contents

Advertisement

TB7600 SERIES COMMUNICATING RTU/HEAT PUMP THERMOSTATS
2 Event Schedule Setup and Examples
Monday timer
Schedule set
Monday
No next
set?Y/N
Yes down
Yes key to access day scheduling, No key to jump to next day
Occupied
No next
Day? Y/N
Yes down
Yes key to access day scheduling, No key to jump to next day
Yes key to copy previous day, No key to set new time value for each day
Occupied
Use
00:00 AM
To set value
to set value, Yes key to confirm
Use
Unoccup
Use
00:00 AM
To set value
Use
to set value, Yes key to confirm
Event
Setpoint
Monday
7.00 AM
Tuesday
7.00 AM
Wednesday
7.00 AM
Thursday
7.00 AM
Friday
7.00 AM
Saturday
12.00 PM *
Sunday
12.00 PM *
* Programming consecutive events to the same time will cause the thermostat to choose the last event as the time at
which it will set its schedule. In the above example, the thermostat will control to the unoccupied set point until
7:00 AM Monday.
Table 10. Example 2 - Commercial building that is occupied all weekend
Event
Setpoint
Monday
8.00 AM
Tuesday
8.00 AM
Wednesday
8.00 AM
Thursday
8.00 AM
Friday
8.00 AM
Saturday
12.00 AM **
Sunday
12.00 AM **
**To program a day as occupied for 24 hours, set that day Occupied time to 12:00 AM and Unoccupied time to
11:59 PM There will be a 1 minute unoccupied period every night at 11:59 PM with this schedule configuration.
62-2016—05
Table 8. Set 2 Events Per Day Menu Navigation
Tuesday timer
Schedule set
Tuesday
No next
set? Y/N
Yes down
Occupied
No next
Day? Y/N
Yes down
Copy Y/N
Yes next
Previous
No down
Occupied
Use
00:00 AM
To set value
Unoccup
Use
00:00 AM
To set value
Table 9. Example 1 - Office building closed all weekend
Period #1 - Event #1
Occupied
Cool
Heat
72 F
70 F
Period #1 - Event #1
Occupied
Cool
Heat
72 F
70 F
Wednesday timer
Schedule set
Wednesda
No next
set? Y/N
Yes down
Occupied
No next
Day? Y/N
Yes down
Copy Y/N
Yes next
Previous
No down
Occupied
Use
00:00 AM
To set value
Unoccup
Use
00:00 AM
To set value
Period #1 - Event #2
Unoccupied
Cool
Heat
80 F
62 F
6.00 PM
6.00 PM
6.00 PM
6.00 PM
6.00 PM
12.00 PM *
12.00 PM *
Period #1 - Event #2
Unoccupied
Cool
Heat
80 F
62 F
5.00 PM
5.00 PM
5.00 PM
5.00 PM
5.00 PM
11.59 PM **
11.59 PM **
12
Other days are identical
Selects the day to be programmed or
modified
Yes = Daily schedules will be accessed
No = Unoccupied mode all day
Yes = Will copy previous day schedule
No = Daily schedules will be accessed
Sets Event # 1 Occupied time
Will activate occupied setpoints
Sets Event # 2 Unoccupied time
Will activate unoccupied setpoints
Daily
Occupancy
Day time only
Day time only
Day time only
Day time only
Day time only
Unoccupied
Unoccupied
Daily
Occupancy
Day time only
Day time only
Day time only
Day time only
Day time only
Occupied
Occupied

Hide quick links:

Advertisement

Table of Contents
loading