Installer
Setup Number
(Press Time
change)
Select
Minimum off time
for the
compressor
Temperature
range stops in
heating
Temperature
range stops in
cooling
Not used
Temperature
display
adjustment
IMPORTANT
Review the settings to confirm that they match
the system. Press Run Program to exit the
Installer Setup. The thermostat has saved the
Installer Setup changes and initiated a reset in
order to operate with the new settings. Be sure to
set the current day and time immediately.

Setting Current Day and Time

Press Set Current Day/Time.
NOTE: On initial power up or after an extended
power loss, 1:00 pm flashes on the dispaly
until a key is pressed.
Time
Set Current
Run
Set Current
Wake
Program
Day/Time
Day/Time
Heat/Cool
Hold Temp
Day
Settings
Daylight
Copy
Time
T8624D CHRONOTHERM
Table 3. Thermostat Installer Setup Options (Continued).
Factory-Setting
key to
Display
33
5
5 minute minimum off
time for the compressor
34
90
Highest setpoint
heating can be set to
35
45
Lowest setpoint cooling
can be set to
36
37
0
No difference in
displayed temperature
and actual room
temperature
Set Day/Time
PM
Set Program
Mon
Leave
Return
Sleep
System
Fan
®
IV DELUXE ZONE MULTISTAGE THERMOSTAT
(Press
Description
Display
0 thru 4 Minimum number of minutes
40 to 89 Temperature range (1°F
46 to 99 Temperature range (1°F
1 thru 6 1—Display adjusts to 1°F
Press Day until the current day is displayed.
NOTE: Sun=Sunday, Mon=Monday,
Day
M10312
7
Other Choices
or
key to change)
Description
(0 thru 5) the compressor will
be off between calls for the
compressor
increments) heating setpoint
can be set to
increments) cooling setpoint
can be set to
higher than actual room
temperature
2—Display adjusts to 2°F
higher than actual room
temperature
3—Display adjusts to 3°F
higher than actual room
temperature
4—Display adjusts to 1°F
lower than actual room
temperature
5—Display adjusts to 2°F
lower than actual room
temperature
6—Display adjusts to 3°F
lower than actual room
temperature
Tue=Tuesday, Wed=Wednesday,
Thu=Thursday, Fri=Friday, Sat=Saturday.
Time
Set Program
Tue
Run
Set Current
Wake
Leave
Return
Sleep
Program
Day/Time
Heat/Cool
Hold Temp
Day
System
Fan
Settings
Daylight
Copy
Time
Actual
Setting
Set Day/Time
PM
M10313
69-1074