Install Turning Vanes
! Mount turning vanes inside the elbow or angle fitting that is
directly against the air cleaner cabinet. See Fig. 7.
Fasten Cabinet To Ductwork
! Install a transition when the opening in the air cleaner
cabinet and the duct are different sizes. See Fig. 4.
! Fasten the other side of the cabinet to the elbow using
sheet metal screws, rivets, or slip joints as appropriate. If
drilling holes, use locking pliers to help hold the unit in place
during drilling. See Fig. 7.
Fig. 7. Connect ductwork to air cleaner. (Note turning
vanes. Locking pliers hold duct to air cleaner cabinet
during installation.)
Seal Joints
! Seal all joints in the return air system between the air
cleaner and the furnace to prevent dust from entering the
clean airstream. Use optional air cleaner cabinet gasket kit
(part no. 32002109-001), mastic or foil tape.
Position Cell Key
The electronic cell must always be installed so the ionizer
section is on the upstream side. A factory-installed cell key on
the bottom of the cabinet allows the cell to be inserted in only
one direction. If the arrow molded into the plastic key points in
the same direction as the airflow, the ionizer is always on the
upstream side.
If position of the key must be reversed, proceed as follows:
1. Remove the electronic cell.
2. Remove the screw holding the cell key in place. See Fig. 8.
Fig. 8. Position of cell key determines orientation of cell
3. Turn the key around and place it over the opposite holes.
TURNING
VANES
4. Tighten the screw into the new hole.
5. Insert the electronic cell. The ionizer section will now be
Attach Cell Handles
Cell handles included with the air cleaner must be installed on
LOCKING
PLIERS
the end of the cell closest to the access door. To install:
1. Orient the cell as it will be when installed. The gray
M20815
2. Hold the handle sideways and insert the solid tab on the
Fig. 9. Install the handle on the end of the cell closest to
3. Insert the divided tab into the square hole.
4. Fold up the wedge and insert it into the divided tab to
9
F300 ELECTRONIC AIR CLEANER
CELL KEY
PREFILTER GUIDES
M5639
(arrow on key must point downstream).
The tab on the bottom fits into the larger hole, and the
screw fits into the smaller hole. Make sure the arrow on
the key points in the direction of the air flow (down-
stream).
on the air-entering (upstream) side of the cabinet.
contact board must be up and the airflow arrow stamped
into the cell must point downstream.
back of the handle into the slot in the cell. Turn the
handle 90 degrees clockwise to align the divided tab with
the square hole. See Fig. 9.
INSTALL HANDLE ON END OF CELL
CLOSEST TO ACCESS DOOR
the access door.
lock the handle in place. If necessary, press with a blunt
instrument like the end of a pliers.
DOWNSTREAM
AIRFLOW
CELL KEY
CELL
SCREW
KEY
ALTERNATE
HOLES FOR
KEY
ROTATE 90
DEGREES
FOLD TAB
TO LOCK
HANDLE
IN PLACE
M6047A
68-0240EF-5