Maintenance Functions; Rebuild - Fujitsu PRIMERGY RX200 S2 User Manual

Onboard scsi raid
Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

4.6

Maintenance Functions

The following is the function that can be executed from GAM at the time of maintenance:
• Rebuilding a Critical logical drive (Rebuild)
4.6.1

Rebuild

When a failed hard disk is replaced, it is necessary to execute a rebuild manually. To execute a rebuild
manually, perform the following procedure.
1
Double-click the Critical logical drive (marked with ! in yellow) in
the [Controller View] window.
The [Logical Drive Information] window appears.
2
Click [Rebuild].
Rebuild starts. When rebuilding is started, the Fault LED of the replaced hard disk that was lit
starts to blink, and turns off after rebuilding is completed.
When the rebuild completes, the following window appears.
The hard disk becomes online and the logical drive is restored to a state of redundancy
(online).