Table 1.4 Minimum And Maximum Virtual Lun Volume Capacities (Open Systems); Control Cylinders/Control Area For Each Lvi/Lu Type; Table 1.5 - Hitachi 9900 V Series User Manual

Lun expansion and virtual lvi/lun
Hide thumbs Also See for 9900 V Series:
Table of Contents

Advertisement

Table 1.4
Minimum and Maximum Virtual LUN Volume Capacities (Open Systems)
Setting size (MB)
35
500
1000
2000
2347
7007
7042
13893
Table 1.5 shows maximum VLL volume capacities of each emulation type.

Table 1.5

Control Cylinders/Control Area for Each LVI/LU Type

LVI Type
3390-3 (A/B/C)
3390-3R
3390-9
3390-L
Note: VLL functions are not applicable to OPEN-L volumes.
8
Chapter 1 Overview of LUN Expansion and Virtual LVI/LUN
PRELIMINARY RELEASE
Actual Size (MB)
35.15625
Minimum VLL volume capacity
500.625
1000.546875
2000.390625
2347.03125
Maximum OPEN-3 volume size
7007.34375
Maximum OPEN-8 volume size
7042.5
Maximum OPEN-9 volume size
13893.04688
Maximum OPEN-E volume size
Control Cylinders
Maximum User Cylinders LU Type
6
3339
6
3339
25
10017
23
32,760
Notes
Maximum User MB
OPEN-3
2347
OPEN-8
7007
OPEN-9
7042
OPEN-E
13893
OPEN-L
Not applicable
Control Area (MB)
5
19
19
13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Freedom storage lightning 9900 v series

Table of Contents