Wsw15; Redial Interval And No. Of Redialings; Crp Option - Brother MFC5490CN Service Manual

Inkjet mfc
Hide thumbs Also See for MFC5490CN:
Table of Contents

Advertisement

Selector
No.
1
Redial interval
2
3
|
No. of redialings
6
Redialing to the called station on
7
the other end sending no response
8

CRP option

• Selectors 1 through 6: Redial interval and No. of redialings
The machine redials by the number of times set by selectors 3 through 6 at intervals set by
selectors 1 and 2.
• Selector 8: CRP option
If a command error occurs in the machine (calling station), the machine usually waits for
three seconds and then makes a retry three times. This CRP option is a request command
that can be sent from the called station for requesting the calling station to retry the failed
command immediately.

WSW15

(REDIAL facility setting)
Function
App. 4-20
Setting and Specifications
No. 1 2
0 0 :
5 minutes
0 1 :
1 minute
1 0 :
2 minutes
1 1 :
3 minutes
No. 3 4 5 6
0 0 0 0
:
0 0 0 1
:
0 0 1 0
:
0 0 1 1
:
|
1 1 1 1
:
0: Yes
0: Disable
16 times
1 times
2 times
3 times
|
15 times
1: No
1: Enable
Confidential