Brother DCP-7030 Service Manual page 262

Laser multi-function center
Hide thumbs Also See for DCP-7030:
Table of Contents

Advertisement

<WSW18>
Selector No.
1
Header for fax
2
Detection enabled time for CNG
and no tone
3
4
Not used.
5
6
Registration of station ID
7
Tone sound monitoring
8
• Selector 1: Header for fax
The setting becomes effective only when do not add the header in the application of the
PC.
• Selectors 2 and 3: Detection enabled time for CNG and no tone
After the line is connected via the external telephone or by picking up the handset of the
machine, the machine can detect a CNG signal or no tone for the time length specified by
these selectors. The setting specified by these selectors becomes effective only when
selector 8 on WSW20 is set to "1."
• Selector 6: Registration of station ID
Setting this selector to "0" permits the registration of station ID for Austrian and Czech
models.
• Selectors 7 and 8: Tone sound monitoring
These selectors set monitoring specifications of the tone sound inputted from the line.
Function
No. 2 3
No. 7 8
App. 1-23
Setting and Specifications
0: With header 1: Without header
0 0: 40 sec.
0 1: 0 sec. (No detection)
1 0: 5 sec.
1 1: 80 sec.
0: Permitted
1: Prohibited
0 0: No monitoring
0 1: No monitoring
1 0: Up to phase B at the calling
station only
1 1: All transmission phases both
at the calling and called stations
Confidential