Samsung Cassette Type Series User Manual

Samsung Cassette Type Series User Manual

Cassette type series 1 way/slim 1 way cassette, 2 way cassette, 4 way/mini 4 way cassette
Hide thumbs Also See for Cassette Type Series:

Advertisement

E
S
F
I
P
D
G
Ne

Air Conditioner

user manual

imagine
Thank you for purchasing this Samsung product.
To receive more complete service, please
register your product at
www.samsung.com/register
R
DB98-29823A (11)
Po
Hu
the possibilities
Cassette Type Series
1 Way/ Slim 1 Way cassette
2 Way cassette
4 Way/ mini 4 Way cassette

Advertisement

Table of Contents
loading

Summary of Contents for Samsung Cassette Type Series

  • Page 1: Air Conditioner

    1 Way/ Slim 1 Way cassette 2 Way cassette 4 Way/ mini 4 Way cassette Air Conditioner user manual imagine the possibilities Thank you for purchasing this Samsung product. To receive more complete service, please register your product at www.samsung.com/register DB98-29823A (11)
  • Page 2 features of your new air conditioner • Cool Summer Offer On those hot sweltering summer days and long restless nights, there is no better escape from the heat than the cool comforts of home. Your new air conditioner brings an end to exhausting hot summer days and lets you rest.
  • Page 3: Safety Information

    Because the following operating instructions cover various models, the characteristics of your air conditioner may differ slightly from those described in this manual. If you have questions, call your nearest contact center or find help and information online at www.samsung.com. What the icons and signs in this user manual mean: Risk of death or serious personal injury.
  • Page 4 safety information SEVERE WARNING SIGNS WARNING If any gas or impurities other than R410A refrigerant come into the refrigerant pipe, serious problem may occur and it may cause injury. Do not spray flammable gases such as insecticide near the air conditioner. •...
  • Page 5 The air conditioner must be installed in accordance with national wiring regulations and safety regulations wherever applicable. Install the supplied cables firmly. Fix them securely so that external force is not exerted to the terminal block. • If the connection is loose, heat may generate and cause electric shock or fire. Use a rated circuit breaker only.
  • Page 6 safety information CAUTION SIGNS CAUTION Do not expose the dust filter to direct sunlight while drying. • Strong direct sunlight may deform the dust filter. Do not allow children to climb on the air conditioner. Use only rated accessories and install the air conditioner with rated equipments. •...
  • Page 7 Check for damage on delivery. If damaged, do not install the air conditioner and call the place of purchase immediately. Insert the dust filter before operating the air conditioner. • If there is no dust filter inside the air conditioner, accumulated dust may shorten the life of the air conditioner and cause electricity waste.
  • Page 8 safety information CAUTION SIGNS CAUTION Make sure the voltage and frequency of the electric system are compatible with the air conditioner. If a power outage occurs while the air conditioner is working, turn off the power source immediately. Max current is measured according to IEC standard for safety and current is measured according to ISO standard for energy efficiency.
  • Page 9: Table Of Contents

    contents VIEWING YOUR AIR CONDITIONER 1 way & slim 1 way cassette 2 way cassette 4 way & mini 4 way cassette USING YOUR AIR CONDITIONER Tips on using your air conditioner CLEANING AND MAINTAINING Cleaning the exterior Cleaning the grille THE AIR CONDITIONER 1 way &...
  • Page 10: Way & Slim 1 Way Cassette

    viewing your air conditioner Congratulations on the purchase of the air conditioner. We hope you enjoy the features of your air conditioner and stay cool or warm with optimal efficiency. Please read the user manual to get started and to make the best use of the air conditioner. 1 WAY &...
  • Page 11: Way & Mini 4 Way Cassette

    4 WAY & MINI 4 WAY CASSETTE Main parts Air flow blade Air intake Air filter (under the grille) Display Display  Type A Type A Remote control sensor Timer indicator Power button Power indicator Fan indicator Removing frost indicator Filter reset indicator ...
  • Page 12: Tips On Using Your Air Conditioner

    using your air conditioner TIPS ON USING AIR CONDITIONER Here are some tips that you would follow when using your air conditioner. TOPIC RECOMMENDATION • If current outside temperatures are much higher than the selected indoor Cooling temperature, it may take time to bring the inner temperature to the desired coolness.
  • Page 13: Cleaning And Maintaining The Air Conditioner

    cleaning and maintaining the air conditioner For the best performance from your air conditioner, clean it periodically. When cleaning, make sure to unplug from the unit for user’s safety. CLEANING THE EXTERIOR When cleaning the exterior, make sure to unplug the power from the unit. No special tools are needed to clean it.
  • Page 14 cleaning and maintaining the air conditioner CLEANING THE GRILLE 2. Unhook the safety clips by holding the front grille. 3. Detach the front grille. Hold the front grille at a 45° angle, lift it up slightly and then pull the grille forward. Hold the grille to prevent dropping outside from the opening of the front grille.
  • Page 15: Way Cassette

    2 way cassette 1. Open the front grille. Push the [] tabs located in 3 places to unlock the groove on the front grille. The grille automatically drops. Two safety clips are mounted to the inside front grille to prevent dropping downward. 2.
  • Page 16 cleaning and maintaining the air conditioner CLEANING THE GRILLE 4 way & mini 4 way cassette 1. Open the front grille. Push both of the tabs outwards to unlock the hook on the front grille. The grille automatically drops. Two safety clips are mounted to the inside front grille to prevent dropping downward.
  • Page 17: Cleaning The Filter

    CLEANING THE FILTER When cleaning the filter, make sure to unplug the power from the unit. Washable foam based Air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. 1 way & slim 1 way cassette 1.
  • Page 18: Way Cassette

    cleaning and maintaining the air conditioner CLEANING THE FILTER When cleaning the filter, make sure to unplug the power from the unit. Washable foam based Air filter captures large particles from the air. The filter is cleaned with a vacuum or by hand washing. 2 way cassette 1.
  • Page 19: Way & Mini 4 Way Cassette

    4 way & mini 4 way cassette 1. Push both of the tabs outwards to unlock the hook on the front grille. The grille automatically drops. Two safety clips are mounted to the inside front grille to prevent dropping downward. 2.
  • Page 20: Maintaining Your Air Conditioner

    cleaning and maintaining the air conditioner MAINTAINING YOUR AIR CONDITIONER If the air conditioner will not be used for an extended period of time, dry the air conditioner to maintain it in best condition. 1. Dry the air conditioner thoroughly by operating in Fan mode for 3 to 4 hours and disconnect the power plug.
  • Page 21: Internal Protections Via The Unit Control System

    Internal protections via the unit control system This internal protection operates if an internal fault occurs in the air conditioner. Type Description The internal fan will be off to against cold air when the heat pump is Against cold air heating.
  • Page 22: Troubleshooting

    appendix TROUBLESHOOTING Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expenses. PROBLEM SOLUTION The air conditioner does not • Because of the protective mechanism, the appliance does not start operating operate immediately after it immediately to keep the unit from overloading.
  • Page 23: Operation Ranges

    OPERATION RANGES The table below indicates the temperature and humidity ranges the air conditioner can be operated within. Refer to the table for efficient use. OUTDOOR INDOOR INDOOR MODE REMARKS TEMPERATURE TEMPERATURE HUMIDITY -5°C/23°F to 43°C/109°F 18°C/64°F to 32°C/90°F DVM, DVM PLUS II/III, BAC Inverter -5°C/23°F to 43°C/109°F 21°C/70°F to 32°C/90°F BAC, Free Joint Multi...
  • Page 24: Installation Part

    Installation Part Screw eight nuts to the suspension bolts making space for hanging the indoor unit. (DVM PLUS II/DVM PLUS III) You must install the suspension bolts more than four when installing the indoor unit. CAUTION Washer Indoor Unit Installation Rubber It is recommended to install the Y-joint before installing the indoor unit.
  • Page 25: Leak Test

    Select the insulation of the refrigerant pipe. Performing Leak Test & Insulation  Insulate the gas side and liquid side pipe referring to the thickness according to the pipe size.  The thickness according to the pipe size is a standard of Leak test the indoor temperature of 27°C and humidity of 80%.
  • Page 26: Wiring Work

     Flexible hose Installation Wiring Work Be horizontal Power and communication cable connection Indoor Indoor Before wiring work, you must turn off all power source. Unit Unit Max. 20mm Flexible hose Indoor unit power should be supplied through the breaker(MCCB, ELB) separated by the outdoor power. ...
  • Page 27: Indoor Unit Setting

    Indoor Unit Setting Additional Functions Before installing the indoor unit, assign an address to the indoor unit according to the air conditioning system plan. The address of the indoor unit is assigned by adjusting MAIN(SW01, SW02) and RMC(SW03, SW04) rotary switches. K1 K2 K3 K4 Function External room sensor...
  • Page 28 RUMANIA network Romtelecom - local tariff / www.samsung.com 021 206 01 10 for landline and mobile, normal tariff 0810 - SAMSUNG(7267864, AUSTRIA www.samsung.com SERBIA 0700 Samsung(0700 726 7864) www.samsung.com € 0.07/min) www.samsung.com/be (Dutch) 0800 - SAMSUNG BELGIUM 02-201-24-18 SLOVAKIA www.samsung.com/sk www.samsung.com/...