Power Supply Cord Connection - Maytag MED7000XG0 Installation Instructions Manual

Electric dryer
Table of Contents

Advertisement

Power
Supply
Cord
Connection
Power supply cord strain relief:
Remove the screws from a 3/4" (19 mm) UL listed strain relief
(UL marking on strain relief). Put the tabs of the two clamp
sections (C) into the hole below the terminal block opening
(B) so that one tab is pointing up (A) and the other is pointing
down (D), and hold in place. Tighten strain relief screws just
enough to hold the two clamp sections (C) together.
Attach
power supply
cord
to strain
relief
Put power supply cord through the strain relief. Be sure that
the wire insulation on the power supply cord is inside the
strain relief. The strain relief should have a tight fit with the
dryer cabinet and be in a horizontal position. Do not further
tighten strain relief screws at this point.
if your outlet looks like this:
Power supply cord 4-wire receptacle
(NEMA Type 14-30R):
Go to 4-Wire Power Supply Cord
Connection
on this page.
Power supply cord 3-wire receptacle
(NEMA Type 10-30R):
Go to 3-Wire Power Supply Cord
Connection
on page 9.
4=Wire Power Supply Cord Connection
IMPORTANT: A 4-wire connection is required for mobile homes
and where local codes do not
4-wire receptacle (NEMA
type 14-30R)
3ermit the use of 3-wire connections.
4-prong plug
Spade terminals with
upturned ends
Ring terminals
, Prepare
to connect
neutral
ground
wire and neutral
wire
Remove center, silver-colored
terminal block screw (B).
Remove neutral ground wire (E) from green external ground
conductor
screw (A).
Connect
neutral
ground
wire and
neutral
wire
8
Connect neutral ground wire (E) and neutral wire (white or
center) (C) of power supply cord under center terminal block
screw (B). Tighten screw.