Maytag MDE17PR Installation Instructions Manual

Commercia ldryer- gas or electric

Advertisement

Available languages

Available languages

INSTALLATION
INSTRUCTIONS
Commercial
Dryer
{3as or Electric
MDE17PR
MDG17PR
INSTRUCTIONS
D'INSTALLATION
S6cheuse
it usage
commercial
il gaz ou 61ectrique
MDE17PD
MDG17PD
TABLE
OF CONTENTS
Page
Dryer Safety .........................................................................
2
Tools & Parts ........................................................................
5
Dimensions/Clearances
......................................................
6
Gas Dryer Installation
Requirements
...................................
7
Electric Dryer Installation
Requirements
...........................
10
Dryer Venting Requirements
.............................................
23
Gas Supply Connection
.....................................................
25
Installing
Leveling Legs ......................................................
17
Electric Dryer Electrical Connections
.................................
18
Leveling .............................................................................
22
Complete Installation
........................................................
23
Reversing Dryer Door Swing ...............................................
24
Maintenance
Instructions
..................................................
25
If You Need Assistance .......................................................
25
Electronic
Control
Setup Instructions
................................
26
Warranty
..........................................................................
31
TABLE
DES MATIERES
Page
S6curit6 de la s6cheuse ......................................................
32
Outils et pi_ces................................................
35
Dimensions/Distances de d6gagement ...........................
36
Exigencesd'installation
pour las6cheuse _ gaz...................
37
Exigencesd'instaHation p our las6cheuse 61ectrique .........
40
Exigencesconcernant V6vacuationde las6cheuse .............
42
Raccordement
_ la canalisation
de gaz ...............................
44
Installation
des pieds de niveHement
.................................
46
NiveHement
........................................................................
46
Achever VinstaHation
..........................................................
47
Inversion du sens d'ouverture
de la porte ...........................
48
Instructions
d'entretien
......................................................
49
Si vous avez besoin d'assistance ..........................................
49
Instructions
de r6gtage du tableau
de commande
61ectronique
...............................................
50
Garantie
............................................................................
56
WIOI84578B
WIOI84579B
- SP
www.maytagcommerciallaundry.com

Advertisement

Table of Contents
loading

Summary of Contents for Maytag MDE17PR

  • Page 1 INSTALLATION INSTRUCTIONS Commercial Dryer {3as or Electric INSTRUCTIONS D'INSTALLATION S6cheuse it usage commercial il gaz ou 61ectrique MDE17PR MDG17PR MDE17PD MDG17PD TABLE OF CONTENTS TABLE DES MATIERES Page Page S6curit6 de la s6cheuse ............Dryer Safety ................. Tools & Parts ................
  • Page 2: Dryer Safety

    DRYER SAFETY Your safety and the safety of others are very important, We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word "DANGER"...
  • Page 3: What To Do If You Smell Gas

    DRYER SAFETY WARNING: For your safety, the information in this manual must be followed to minimize the risk of fire or explosion, or to prevent property damage, personal injury, or death, - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 4: Important Safety Instructions

    DRYER SAFETY iMPORTANT SAFETYiNSTRUCTiONS WARNING: To reduce the risk of fire, electric shock, or injury to persons when using the dryer, follow basic precautions, including the following: Read all instructions before using the dryer. Clean dryer lint screen before or after each load. This dryer is intended only for drying clothes and textiles Do not use this dryer without the lint screen in place.
  • Page 5: Tools And Parts

    TOOLS & PARTS Tools Needed: 8" (200 ram) flat-blade screwdriver 8" (200 ram) or 10" (250 ram) phillips screwdriver or 10" (250 ram) adjustable wrench pipe wrench that opens to 1" (25 ram} 1" (25 ram) hex-head 5/16"(8ram)socket wrench pliers (that open to Torx®$ T-20 security screwdriver or bit...
  • Page 6 _CLEARANCES Dimensions Front View Side View 291/4" __i(743 ram) Non=coin-operated 261/2. ------_ models: (673 ram} 71/8'' (181 ram) Coin=operated models: 77/8 '' (200 ram) (1.089 m) 35" (889 ram) 31/4 =' (83 mm) 1 " (25 ram) 101/4" 3/4" (260 ram) Back View (21 ram) Bottom...
  • Page 7: Gas Dryer Installation Requirements

    GAS DRYER INSTALLATION REQUIREMENTS Location requirements Recessed Area and Closet installation instructions This dryer may be installed in a recessed area or closet. recessed area and closet installations, minimum clearances can be found on the warning label on the rear of the dryer or in "Dimensions/Clearances."...
  • Page 8 GAS DRYER INSTALLATION RE UIREMENTS Electrical Requirements Gas Dryer Grounding GROUNDING INSTRUCTIONS [] For a grounded, cord-connected dryer: This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current. This dryer uses a cord having an equipment-grounding Electrical Shock Hazard conductor and a grounding plug.
  • Page 9 GASDRYER INSTALLATION Gas Supply Explosion Hazard Use a new CSA international approved gas supply line. |nstall a shut=off valve, Securely tighten all gas connections. if connected to LP, have a qualified person make sure gas pressure does not exceed 13" (330 ram) water column.
  • Page 10 ELECTRIC DRYER INSTALLATION RE UIREMENTS Location Requirements The dryer must be exhausted outdoors. ÷ 48 in.2 (310 cm 2) 3" (76 mn Explosion Hazard Keep flammable materials and vapors, such as gasoline, away from dryer. front closet view door Do not install in a garage. ©...
  • Page 11 ELECTRICDRYER INSTALLATION Electrical Requirements - U.S.A. only (cont.) Electrical Connection Electric Dryer Power Supply Cord To properly install your dryer, you must determine the type of electrical connection you will be using and follow the instructions provided for it here. This dryer is manufactured ready to install with a 3-wire electrical supply connection.
  • Page 12 ELECTRIC DRYER INSTALLATION RE UIREMENTS Direct Wire If connecting by direct wire: Power supply cable must match power supply (4-wire 3-wire) and be: Flexible armored cable or nonmetallic sheathed copper cable (with ground wire), covered with flexible metallic conduit. All current-carrying wires must be insulated.
  • Page 13 DRYER VENTING Elbows: 45 ° elbows provide better airflow than 90 ° elbows....Fire Hazard Use a heavy metal vent, Do not use a plastic vent, Do not use a metal foil vent, Failure to follow these instructions can result in death Clamps: or fire, Use clamps to seal all joints.
  • Page 14 DRYER VENTING RE UIREMENTS Vent Hoods 4" (102 mm) Diameter Exhaust Hoods Exhaust hood must be at least 12" (305 mm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks, bushes, or snow). box hood louvered hood angled hood...
  • Page 15: Gas Supply Connection

    DRYER VENTING If an Exhaust Hood Cannot be Used Multiple Dryer Venting The outside end of main vent should have a sweep elbow A main vent can be used for venting a group of dryers. The directed downward. main vent should be sized to remove 5663 I/min. (200 CFM) of air per dryer.
  • Page 16 GAS SUPPLY CONNECTION Type of Gas This dryer is equipped for use with natural gas. It is design- certified by CSA International for LP (propane and butane) gases with appropriate conversion. No attempt shall be made to convert dryer from gas specified on serial/rating plate for use...
  • Page 17: Installingleveling Legs

    INSTALLINGLEVELING LEGS The console houses the electronic control board. The board is 2. Screw in leveling legs factory set for a dry time of 45 minutes. Consult the tech sheet Examine leveling legs and find diamond diamond found inside the dryer toe panel to reset dry time and for other marking.
  • Page 18: Electric Dryer Electrical Connections

    ELECTRIC DRYER ELECTRICAL CONNECTIONS Strain Relief Remove Terminal Block Cover Power Supply Cord Strain Relief 1. Insert strain relief. 2. Insert power cord into strain relief. Strain Relief Direct Wire Strain Relief 1. Insert strain relief. 2, Insert conduit into strain relief and tighten clamp.
  • Page 19 ELECTRIC DRYER ELECTRICAL CONNECTIONS Connection Options Power Cord Direct Wire 4-wire receptacle (NEMA Type 14-30R) 4-wire direct (127 3-wire receptacle (NEMA Type 10-30R) 3-wire direct Connecting 4-Wire Connection: Power Supply Cord IMPORTANT: A 4-wire connection is required for mobile homes and where local codes do not permit the use of 3-wire connections.
  • Page 20 ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 3-Wire Connection: Power Supply Cord 2. Connect neutral wire to center terminal block. Standard Power Cord Connectors Flanged spade connector Ring Connector Connecting Neutral Wire 1. Loosen or remove center terminal block screw. 3. Connect remaining wires with outer terminal block screws.
  • Page 21 ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 4-Wire Connection: Direct Wire Connecting Ground and Neutral Wires (cont.) Connecting Remaining Wires 2. Connect ground and neutral wire to center terminal block. 4. Connect remaining wires to outer terminal block. Connecting Direct Wire Ground 3.
  • Page 22: Leveling

    ELECTRIC DRYER ELECTRICAL CONNECTIONS Connecting 3=Wire Connection: Optional Use for direct wire or power supply cord where tocal codes do not permit connecting cabinet-ground conductor to neutral were. Connecting Neutral WEre 1. Remove center terminal block screw. Also remove neutral 3.
  • Page 23: Complete Installation

    LEVELING 2. Grip dryer from top and rock back and forth, making sure all HELPFUL TiP: You may want to prop up front of dryer about 4" four legs are firmly on floor. Repeat, rocking dryer from side (102 mm) with a wood block or similar object that will support to side.
  • Page 24: Reversing Dryer Door Swing

    REVERSING DRYER DOOR SWING You can change your door swing from a right-side opening to Be certain to keep cardboard spacer centered between left-side opening, if desired. doors. Reattach outer door panel to inner door panel so handle is on the side where hinges were just removed.
  • Page 25: Maintenance Instructions

    IF YOU NEED ASSISTANCE Contact your authorized Maytag ® Commercial Laundry distributor. To locate your authorized Maytag ® Commercial Laundry distributor, or for web inquiries, visit www.MaytagCommercialLaundry.com. If you cannot locate your distributor, the Commercial Laundry Support Center will answer...
  • Page 26: Electroniccontrol Setup Instructions

    ELECTRONICCONTROL SETUP INSTRUCTIONS Accumulator Pricing IMPORTANT If the price is set to one coin 1, then accumulator pricing Electrostatic Discharge (ESD) is in effect. Cycle time can be purchased one coin at a time (PD models) up to the maximum time of 99 minutes. Stacked Sensitive Electronics PD models will credit all money to a cycle with a single button ESD problems...
  • Page 27 ELECTRONICCONTROL SETUP INSTRUCTIONS The set-up code is indicated by the one or two left-hand Control Set-up Procedures characters. The set-up code value is indicated by the two or IMPORTANT: Read all instructions before operating. three right-hand characters. The fabric setting buttons along with the digital display are Code used to set up the dryer controls.
  • Page 28 ELECTRONICCONTROL SETUP INSTRUCTIONS OPTIONS 3.XX-9.XX TO USE IF SPECIAL PRICING Code Explanation IS SELECTED 1.00 MONEY COUNTER OPTION Code Explanation This option is either NOT SELECTED"OFF" or SELECTED"ON." 3.06 SPECIAL CYCLE PRICE 3.06 Represents the number of quarters (coin 1) 1.
  • Page 29 ELECTRONICCONTROL SETUP INSTRUCTIONS Code Code Explanation Explanation b. 05 7.00 SPECIAL PRICESTART HOUR VALUE OF COIN 1 NOTE: Uses military time or 24 hr. clock. b. 05 This represents the value of coin i in number 7. O0 of nickels: 05 = S0.25. This is the start hour;...
  • Page 30 ELECTRONICCONTROL SETUP INSTRUCTIONS END of SET-UP PROCEDURES Code Explanation EXIT FROM SET-UP MODE J. Cd PAYMENT MODE (COIN/DEBIT OPTION) Single-Load PD Models: Reinstall access door. J. Cd Both coin and debit selected. Press the DELICATES button 3 consecutive times to change this selection.
  • Page 31: Warranty

    MAYTAG ®COMMERCIAL WASHER, DRYER, STACKED DRYER/DRYER,COMMERCIALSTACKLAUNDRY, AND MULTI-LOADCOIN OPERATED COMMERCIAL WASHERS AND DRYERS WARRANTY LiMiTED WARRANTY ON PARTS For the first five years from the date of purchase, when this commercial appliance is installed, maintained and operated according to instructions...
  • Page 32 SECURITE DE LA SECHEUSE Votre s6curit6 et celle des autres est tr_s importante. Nous donnons de nombreux messages de s6curit6 importants dans ce manuel et sur votre appareil m6nager. Assurez-vous de toujours lire tous les messages de securit6 et de vous y conformer. Ce symbole d'alerte de s6curit6 vous signale les dangers potentiels de d6ces et de blessures graves a vous et b, d'autres.
  • Page 33: Securite De La Secheuse

    SECURITE DE LA SECHEUSE AVERTISSEMENT : Pour votre s6curit6, les renseignements darts ce manuel doivent 6tre observ6s pour r6duire au minimum les risques d'incendie ou d'e×plosion ou pour 6viter des dommages au produit, des blessures ou un d6ces. - Ne pas entreposer ou utiliser de I'essence ou d'autres...
  • Page 34 SECURITE DE LA SECHEUSE IMPORTANTES INSTRUCTIONS DE SI CURITI AVERTISSEMENT : Pour r_duire les risques d'incendie, de choc _lectrique ou de blessures lors de l'utilisation de la s_cheuse, suivre les pr6cautions fondamentales dont les suivantes : Lire toutes les instructions avant d'utiliser la s6cheuse.
  • Page 35: Outils Et Pieces

    OUTILS ET PIECES Outillage n6cessaire c16_ tuyau c16_ molette de 8" (200 ram) tournevis _ lame plate tournevis Phillips de 8" (200 ram) ou 10" (250 ram) (ouverture ou 10" (250 ram) jusqu'_ i" [25 mm]) tournevis isol6 ou foret cl6 _ douille hexagonale c16 _ douille...
  • Page 36 DISTANCES DE DEGAGEMENT Dimensions Vue de face Vue lat6rale 291/4'' 27" -4---- (743 mm) -----_ (686 ram) r=7= 261/2'' (673 ram) ModUles non payants : 71/8'' (181 mm) ModUles payants ram) 77/8 '' (200 427/8`` (1.089m) 35" (889 ram) 31/4" (83 mm) 1"...
  • Page 37 EXIGENCES D'INSTALLATIONPOUR LA SECHEUSE A GAZ Exigences de I'emplacement instructions d'instaltation dans un encastrement ou un placard Cette s6cheuse peut _tre install_e dans un encastrement un placard. Pour les installations dans un encastrement ou un placard, les distances de d_gagement minimales sont indiqu_es sur I'_tiquette...
  • Page 38 EXIGENCES D'INSTALLATIONPOUR LA SECHEUSE A GAZ Sp6cifications 61ectriques Mise _ la terre de la s6cheuse_ gaz iNSTRUCTiONS DE LiAiSON ._ LA TERRE [] Pour une s6cheuse reli_e & la terre et connectee par un cordon : Cette s_cheuse dolt &tre reli6e & la terre. En cas de mauvais fonctionnement ou de panne, la liaison &...
  • Page 39 EXIGENCES D'INSTALLATIONPOUR LA SECHEUSE A GAZ Alimentation en gaz Risque d'explosion Utiliser une canalisation neuve d'arriv6e de gaz approuv6e par CSA international. installer un robinet d'arr6t. Bien setter chaque organe de connexion de la canalisation de gaz, En cas de connexion au gaz propane, demander _ une...
  • Page 40 EXIGENCES D'INSTALLATIONPOUR LA SECHEUSE ELECTRIQUE Exigences de I'emplacement Si une porte de placard est install_e, une ouverture d'_vacuation de I'air minimale est n_cessaire dans les parties sup_rieure et inf_rieure. Les portes _ claire-voie offrant ouvertures _quivalentes sont acceptables. La s_cheuse doit _tre _vacu_e _ I'ext_rieur.
  • Page 41 EXIGENCES D'INSTALLATIONPOUR LA SECHEUSE ELECTRIQUE Sp6cifications 61ectriques Ne pas utiliser de c_ble de rallonge. Si on utilise un cordon d'alimentation de rechange, il est recommand6 d'utiliser le cordon d'alimentation de rechange num6ro de piece 9831317. Pour plus d'information, veuillez consulter les num6ros de service qui se trouvent...
  • Page 42 EXIGENCES CONCERNANT L'EVACUATION DE LA SECHEUSE REMARQUE : Lors de I'utilisation d'un syst_me d'_vacuation existant, nettoyer et _liminer la charpie sur toute la Iongueur du syst_me, et veiller _ ce que le clapet d'_vacuation ne soit pas obstru_ par de la charpie. Remplacer tout conduit...
  • Page 43 EXIGENCES CONCERNANT L'EVACUATION DE LA SECHEUSE Hottes d'extraction Ctapets d'6vacuation - Diam_tre de 4" (102 ram) Le clapet de d@charge doit se trouver fi au moins 12" (305 mm) au-dessus du sol ou de tout autre objet susceptible de se trouver sur le trajet de I'air humide...
  • Page 44 EXIGENCES CONCERNANT L'EVACUATION DE LA SECHEUSE Si on ne peut pas utiliser de clapet d'6vacuation Evacuation pour plusieurs s6cheuses L'ext_rieur du conduit d'_vacuation principal doit comporter On peut utiliser un conduit principal pour assurer I'_vacuation un conduit de d_viation orient_ vers le bas. d'un ensemble de s_cheuses.
  • Page 45 RACCORDEMENT A LA CANALISATION DE GAZ Type de gaz Cette s_cheuse est _quip_e pour une alimentation au gaz de celui indiqu_ sur la plaque signal_tique sans consulter naturel. Sa conception est homologu_e par CSA international le fournisseur de gaz au pr_alable. L'op_ration de conversion doit...
  • Page 46 INSTALLATION DES PIEDS DE NIVELLEMENT/NIVELLEMENT Nivellement installation des pieds de nivellement La console renferme le panneau de contr61e _lectronique. Le nivellement de la s6cheuse permet de r_cluire le bruit et les vibrations excessifs. panneau est configur_ _ I'usine pour une clur_e de s_chage 45 minutes.
  • Page 47: Achever L'installation

    NIVELLEMENT 3. Si la s6cheuse n'est pas d'aplomb, utiliser une cl6 plate ou une cl_ _ molette de 1" ou 25 mm pour tourner les contre-_crous dans le sens horaire (vue du dessus) sur les pieds jusqu'_ qu'ils se trouvent a environ 1/2"...
  • Page 48: Inversion Du Sens D'ouverture De La Porte

    INVERSION DU SENS D°OUVERTUREDE LA PORTE Le sens d'ouverture de la porte peut _tre chang_ du c6t_ droit 7. Veiller _ maintenir la cale d'espacement en carton centr_e au c6t6 gauche, si d_sir_. entre les portes. Fixer _ nouveau le panneau de porte a la porte...
  • Page 49: Instructions D'entretien

    _ usage commercial Maytag ®. Pour Iocaliser votre revendeur autoris_ d'appareils de buanderie _ usage commercial Maytag ® ou pour toute question via [nternet, consulter www.MaytagCommercialLaundry.com. Si vous ne parvenez pas _ Iocaliser un revendeur, le centre d'aide...
  • Page 50 INSTRUCTIONS DE REGLAGEDU TABLEAU DE COMMANDE ELECTRONI UE II existe quatre (4} types de tarif de la s6cheuse : iMPORTANT Tarif de vente fixe Circuits 61ectroniques sensibles au× d6charges 61ectrostatiques Un param_trage de la s6cheuse pour un fonctionnement en programme fixe peut accepter uniquement les dur_es Le risque de d6charge 61ectrostatique...
  • Page 51 INSTRUCTIONS DE REGLAGEDU TABLEAU DE COMMANDE ELECTRONIQUE Affichage IMPORTANT : Ne pas ouvrir la console avant d'avoir d_connect_ la s_cheuse detoute source d'_nergie. Pour acceder au connecteur Une fois la s_cheuse install_e et branch_e, I'affichage indique AA1 : "0 minutes". D_brancher la s_cheuse ou d_connecter la source de courant...
  • Page 52 INSTRUCTIONS DE REGLAGEDU TABLEAU DE COMMANDE ELECTRONI UE Code Explication Code Explication DUREE DE SECHAGE NORMAL 1.00 OPTION DE COMPTAGE DE MONNAIE Cette option est soit non s61ectionn_e ("OFF"), soit MODI:LES PD : Repr6sente le nombre de minutes s_lectionn_e ("ON"). par pi6ce de 0,25 $ (piece 1).
  • Page 53 INSTRUCTIONS DE REGLAGEDU TABLEAU DE COMMANDE ELECTRONIQUE OPTIONS 3.XX - 9.XX _. UTlUSER EN CAS DE SleLECTIONDE Code Explication TARIF SPleCIAL 8.00 HEURE DE FIN DU TARIF SPI_CIAL REMARQUE : Utilise le format sur 24 heures. Code Explication 3.06 PRIX DU PROGRAMME SPleCIAL 8.00 Repr@sente l'heure de fin, entre 0 et 23 heures.
  • Page 54 INSTRUCTIONS DE REGLAGEDU TABLEAU DE COMMANDE ELECTRONI UE Explication Code Explication Code b. 05 VALEUR DE LA PIi:CE 1 J. Cd MODE DE PAIEMENT (OPTION DE PII:CES/D#BIT) Modes pi6ces et carte de d6bit s61ectionn@s. Appuyer b. 05 Repr@sente la valeur de la piece 1 en nombre J.
  • Page 55: Guide De Diagnostic

    INSTRUCTIONS DE REGLAGEDU TABLEAU DE COMMANDE ELECTRONIO U_E_ FIN des OPI_RATIONS DE PARAME_TRAGE QUITTER LE MODE DE PARAMI-"TRAGE ModUles PD _ une seule charge : r_installer la porte d'acc_s. Mod_Jes PR _ une seule charge : D_brancher la s_cheuse ou d@connecter la source de courant @lectfique.
  • Page 56: Garantie

    Pendant cinq ans _ compter de la date d'achat, Iorsque cet appareil m_nager commercial est installS, utilis6 et entretenu conform_ment aux instructions jointes _ ou fournies avec le produit, Maytag marque de Whirlpool Corporation (ci-apr6s d_sign_e "Maytag') paiera pour les pi6ces de rechange sp_cifi_es par I'usine ou les pi6ces de rechange d'_quipement...

This manual is also suitable for:

Mdg17pdMde17pdMdg17pr

Table of Contents