Reinstall blower
For vented installation
only:
IMPORTANT: To avoid damage, do not grasp blower by blower
wheels.
1. Position blower so that blower discharge lines up with
damper/vent
connector.
Horizontal Vent
A
_
I
........
i
,!
L
_
Vertical Vent
A
A. Blower discharge
2. Slip rods into mounting brackets on blower assembly.
3. Slip rods into mounting brackets.
BC
D
A. Blower
B. Mounting rod
C. Knurled nut
D. Blower wiring plug
4. Securely tighten knurled nuts.
5. Reconnect blower plug.
6. Using a flat-blade screwdriver
panel.
pry louver cover off control
.............
BC
D
A. Blower
B. Mounting rod
C. Knurled nut
D. Blower wiring plug
3. Securely tighten knurled nuts.
4. Reconnect blower plug.
5. Reinstall bottom cover.
For non-vented
(recirculating)
installation
only:
IMPORTANT: To avoid damage, do not grasp blower by blower
wheels.
1. Move mounting rods to front holes in hood support channels.
2. Position blower so that blower discharge lines up with
Iouvered opening on hood front.
A
i
.
i
A. Front holes
B. Blower discharge
A. Louver cover
7. Reinstall bottom cover.
Install 2 x 75-watt
(max.) or 1 x 75-watt
and 1 x 25-watt
incandescent
light bulbs.
1. Squeeze the plastic lens cover and remove it from the hood.
2. Screw light bulb into socket. If you are using a 25-watt light
bulb as a night light, screw into right-hand socket.
3. Repeat Step 2 for the other light bulb.
4. Replace lens cover by squeezing cover and inserting tabs
into slots.
Install filters
See "Metal Grease Filter" or "Non-vented
(recirculating)
Installation Filters" in the "Range Hood Care" section.