KitchenAid YKEYS710LQ0 Installation Instructions Manual page 9

29 in. (73.7cm) electric dryer
Table of Contents

Advertisement

Available languages

Available languages

4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external
ground connector screw to an adequate ground.
3
R
1. External ground connector
2. Neutral grounding
wire (green/yellow)
3. Neutral wire (white or center wire)
4. Grounding path determined by a qualified electrician
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
Use clamps to seal all joints. Exhaust vent must not be
connected or secured with screws or other fastening devices
which extend into the interior of the duct. Do not use duct
tape.
IMPORTANT: Observe all governing codes and ordinances.
_mproper venting
can cause moisture
and mintto co,meet
indoors,
which
may resumt in:
[]
Moisture damage to woodwork,
furniture, paint, wall-
paper, carpets, etc=
[]
Housecleaning
problems and health problems.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home.
Exhaust hood must be at least 12 in. (30.5 cm) from the ground or
any object that may be in the path of the exhaust (such as flowers,
rocks or bushes, etc.).
If using an existing vent system, clean lint from the entire length of
the system and make sure exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid metal or flexible
metal vent.
Fire Hazard
Use a heavy metam vent.
Do not use a pmastic vent.
Do not use a meta_ foil vent.
Failure to follow
these instructions
can result in death
or fire.
WARNING;
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
4 in. (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE
TM
venting products are recommended.
DURASAFE
TM
vent products can be purchased from your dealer
or by calling Whirlpool Parts and Accessories.
For more
information, see the "Assistance
or Service" section of your
"Dryer User Instructions."
Typical exhaust
installations
Typical installations vent the dryer from the rear of the dryer.
2
1. Dryer
5. Clamps
2. Elbow
6. Rigid metal or flexible metal vent
3. Wall
7. Vent length necessary to connect
4. Exhaust hood
elbows
8. Exhaust outlet

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Keys850lq1

Table of Contents