Download Print this page

Technical Specifications - HP DL385 Quickspecs

Carrier-grade server
Hide thumbs Also See for DL385:

Advertisement

QuickSpecs

Technical Specifications

System Unit
System Unit
System Unit
System Unit
Dimensions (H x W x D)
Dimensions
Dimensions
Dimensions
(with bezel)
Weight (approximate)
Weight
Weight
Weight
Input Requirements
Input Requirements
Input Requirements
Input Requirements
(per power supply)
BTU Rating
BTU Rating
BTU Rating
BTU Rating
Power Specifications
Power Specifications
Power Specifications
Power Specifications
Power Supply Output
Power Supply Output
Power Supply Output
Power Supply Output
Power
Power
Power
Power
(per power supply)
System Inlet Temperature Operating
System Inlet Temperature
System Inlet Temperature
System Inlet Temperature
Relative Humidity
Relative Humidity
Relative Humidity
Relative Humidity
(non-condensing)
Altitude
Altitude
Altitude
Altitude
Acoustic Noise
Acoustic Noise
Acoustic Noise
Acoustic Noise
DA - 13086
North America — Version 5 — April 3, 2009
HP ProLiant DL385 Generation 5 (G5) Carrier-Grade
HP ProLiant DL385 Generation 5 (G5) Carrier-Grade
HP ProLiant DL385 Generation 5 (G5) Carrier-Grade
HP ProLiant DL385 Generation 5 (G5) Carrier-Grade
3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm)
Maximum
(all hard drives, power
supply, and processor
installed)
Minimum
(one hard drive, power
supply, and processor
installed)
Rated Line Voltage
Rated Input Current
Rated Input Frequency
Rated Input Power
Maximum
Rated Steady-State Power
Maximum Peak Power
Non-operating
Operating
Non-operating
Operating
Non-operating
Listed are the declared A-Weighted sound power levels (LWAd) and declared
average bystander position A-Weighted sound pressure levels (LpAm) when
60 lb (27.22 kg)
47.18 lb (20.41 kg)
3350 BTU/hr (at 100 VAC),
3530 BTU/hr (at 120 VAC),
3990 BTU/hr (at 240 VAC)
10° to 35°C (50° to 95°F) at sea level with an
altitude derating of 1.0°C per every 305 m
(1.8°F per every 1000 ft) above sea level to a
maximum of 3050 m (10,000 ft), no direct
sustained sunlight. Maximum rate of change is
10°C/hr (18°F/hr). The upper limit may be
limited by the type and number of options
installed.
System performance may be reduced if operating
with a fan fault or above 30°C (86°F).
-30° to 60°C (-22° to 140°F). Maximum rate of
change is 20°C/hr (36°F/hr).
10 to 90% relative humidity (Rh), 28°C (82.4°F)
maximum wet bulb temperature, non-
condensing.
5 to 95% relative humidity (Rh), 38.7°C
(101.7°F) maximum wet bulb temperature, non-
condensing.
3050 m (10,000 ft). This value may be limited by
the type and number of options installed.
Maximum allowable altitude change rate is 457
m/min (1500 ft/min).
9144 m (30,000 ft). Maximum allowable
altitude change rate is 457 m/min (1500 ft/min).
Server
Server
Server
Server
Page 24

Advertisement

loading

This manual is also suitable for:

Proliant dl385 generation 5Proliant dl385 g5