Test to verify if "LO or LOW" setting should be adjusted (all
other positions):
1.
Follow steps a thru d above.
2.
Insert a thin-bladed
screwdriver into the hollow valve
stem and engage the slotted screw inside. Flame size
can be increased or decreased with the turn of the
screw. Turn counterclockwise
to increase flame size.
Turn clockwise to decrease flame size.
After installation
is complete,
make all
controls
are left in the OFF position.
Model and serial number
location
The Serial Plate is located on the right-hand surface of the
oven front frame at the storage or warmer drawer; or the
lower panel area (See Fig. 41).
When ordering parts for or making inquires about your
range, always be sure to include the model and serial
numbers and a lot number or letter from the Serial Plate on
your range. The Serial Plate will also inform you of the
rating of the burners, the type of fuel and the pressure the
range was adjusted for when it left the factory.
Care, cleaning and maintenance
Refer to the Use & Care Guide for cleaning
instructions. If removing the range is necessary for
cleaning or maintenance, shut off the gas supply.
Disconnect the gas and electrical supply. If the gas or
electrical supply is inaccessible, lift the range slightly at
the front and pull out away from the wall. Pull only as far
as necessary to disconnect the gas and electrical supply.
Finish removing the range for servicing and cleaning.
Reinstall in reverse order making sure to level the range
and check gas connections for leaks. See anti-tip
instructions for proper anti-tip anchoring instructions.
Before
you call for service
Refer to the Use & Care Guide for cleaning
instructions. If removing the range is necessary for
cleaning or maintenance, shut off the gas supply.
Disconnect the gas and electrical supply. If the gas or
electrical supply is inaccessible, lift the range slightly at
the front and pull out away from the wall. Pull only as far
as necessary to disconnect the gas and electrical supply.
Finish removing the range for servicing and cleaning.
Reinstall in reverse order making sure to level the range
and check gas connections
for leaks. See page 3 of this
document for proper anti-tip anchoring instructions.
Serial plate is located on the Iowerrig
frame of the appliance.
Alternate
location
may be under cooktop.