LOG SENSE
Code
Flag
Type
12h
Tape
Directory
Corrupted on
Load
13h
Nearing
Media Life
14h
Clean Now
15h
Clean
Periodic
16h
Expired
Cleaning
Media
17h
Invalid
Cleaning
Tape
18h
Retention
Requested
19h
Dual-Port
Interface
Error
1Ah
Cooling Fan
Failure
1Bh
Power
Supply
1Ch
Power
Consumption
1Dh
Drive
Maintenance
SONY AIT-4 drive SDX-900V series Ver.2.1
Flag Type
Recommended application client message
O
W
The directory on the tape cartridge has been
corrupted.
File search performance will be degraded. The
tape directory can be rebuilt by reading all the
data on the cartridge
O
I
The tape cartridge is nearing the end of its
calculated life. It is recommended that you:
1. Use another tape cartridge for your next
backup.
2. Store this tape cartridge in a safe place in case
you need to restore data from it.
M
C
The tape drive needs cleaning:
1. If the operation has stopped, eject the tape and
clean the drive
2. If the operation has not stopped, wait for it to
finish and then clean the drive.
Check the tape drive user's manual for device
specific cleaning instructions.
O
W
The tape drive is due for routine cleaning:
1. Wait for the current operation to finish.
2. Then use a cleaning cartridge.
Check the tape drive user's manual for device
specific cleaning instructions.
M
C
The last cleaning cartridge used in the tape drive
has worn out:
1. Discard the worn out cleaning cartridge.
2. Wait for the current operation to finish.
3. Then use a new cleaning cartridge.
O
C
The last cleaning cartridge used in the tape drive
was an invalid type:
1. Do not use this cleaning cartridge in this drive.
2. Wait for the current operation to finish.
3. Then use a valid cleaning cartridge.
O
W
The tape drive has requested a retention
operation
O
W
A redundant interface port on the tape drive has
failed
O
W
A tape drive cooling fan has failed.
O
W
A redundant power supply has failed inside the
tape drive enclosure. Check the enclosure user's
manual for instructions on replacing the failed
power supply.
O
W
The tape drive power consumption is outside the
specified range
O
W
Preventive maintenance of the tape drive is
required.
Check the tape drive user's manual for device
specific preventive maintenance tasks or call the
tape drive supplier helpline.
6.Command Specification
Probably cause
Tape drive powered
down with tape loaded,
or permanent error
prevented the tape
directory being updated
Media may have
exceeded its specified
number of passes
The drive thinks it has a
head clog, or needs
cleaning
The drive is ready for a
periodic clean
The cleaning tape has
expired
Invalid cleaning tape
type used
The drive is having
severe trouble reading
or writing, which will be
resolved by a retention
cycle
Failure of one interface
port in a dual-port
configuration, e.g. Fibre
channel
Fan failure inside tape
drive mechanism or
tape drive enclosure
Redundant PSU failure
inside the tape drive
enclosure or rack
subsystem
Power consumption of
the tape drive is outside
specified range
The drive requires
preventative
maintenance (not
cleaning).
6-21