6.Command Specification
CLN: When this bit is set, it indicates drive request cleaning . Refer to the clause 4.5.1
MEW: When this bit is set, it indicates Media Warning. Refer to the clause 4.5.2.3
A description of the different Sense Keys (Byte 2), Additional Sense Codes (Byte 12), and the Additional Sense
Code Qualifiers (Byte 13) supported by the SDX-900V are listed in a table beginning on the following page.
The following Table shows the REQUEST Sense Keys and the Additional Sense Key (Byte 12) and the Additional
Sense Key Qualifier (Byte 13) supported by the SDX-900V:
Sense
Bytes
Key
12
13
00h
00
00
00
01
00
02
00
03
00
04
00
05
01h
5D 00
02h
04 00
04 01
30 03
3A 00
3A 04
6-88
Table 6-90: Sense Key Descriptions
NO SENSE: Indicates that there is no specific sense key information to be reported for
the designated logical unit. This would be the case for a successful command or a
command that received CHECK CONDITION or COMMAND TERMINATED status
because one of the File-mark, EOM, or ILI bits is set to one. For File-mark or Set-mark
detected the drive will be positioned on the EOM side of the mark if the drive direction
was forward and on the BOM side of the mark if the direction was reverse.
NO ADDITIONAL SENSE INFORMATION
FILEMARK DETECTED
END-OF-PARTITION/MEDIUM DETECTED
SETMARK DETECTED
BEGINNING-OF-PARTITION/MEDIUM DETECTED
END-OF-DATA DETECTED
RECOVERED ERROR.
FAILURE PREDICTION THRESHOLD EXCEEDED
NOT READY. Indicates that the logical unit addressed cannot be accessed. Operator
intervention may be required to correct this condition. Typically this indicates that there
is no tape loaded. This status is also returned if the drive is currently rewinding
following REWIND with Immediate bit set and another command is received (except
for INQUIRY and READ BLOCK LIMITS which return GOOD status).
LOGICAL UNIT NOT READY - Media is present within the drive.
This status is returned to any tape motion command following UNLOAD with
Immediate bit set or if the Eject button has been pressed by the operator. Also can be
caused by the command sequence, PREVENT ALLOW MEDIA REMOVAL with
Prevent bit set followed by UNLOAD. Tape motion commands such as READ, WRITE
or SPACE are not allowed but Diagnostics which do not access the tape are permitted.
LOGICAL UNIT IS IN PROCESS OF BECOMING READY - This status is returned
following a LOAD command with the IMMED bit set for any tape motion command
before the tape is loaded. Also during the auto load following a tape insertion.
CLEANING CARTRIDGE INSTALLED
MEDIUM NOT PRESENT - This status is returned for all tape motion commands when
there is no media within the tape.
MEDIUM NOT PRESENT MAM ACCESSIBLE