MAINTENANCE
CAUTION:
Always be sure that the tool is switched off and unplugged before attempting t o perform
inspection or maintenance.
Replacing carbon brushes
When the resin insulating tip inside the
carbon brush is exposed t o contact the
commutator, it will automatically shut off the
motor. When this occurs, both carbon
brushes should be replaced at the same time.
Use only identical carbon brushes.
Use a screwdriver
remove the brush holder
caps. Take out the worn carbon brushes,
insert the new ones and secure the brush
holder caps.
Insulating tip
>I--
Commutator
-Carbon
brush
1
To maintain product SAFETY and RELIABILITY, repairs, any other maintenance or adjust-
ment should be performed by Makita Authorized or Factory Service Centers, always using
Makita replacement parts.
9