Specifications; Ordering Information - Honeywell T8400C Product Data

Electronic thermostats
Table of Contents

Advertisement

T8400C, T8401C AND T8424C,D ELECTRONIC THERMOSTATS

SPECIFICATIONS

IMPORTANT
The specifications given in this publication do not
include normal manufacturing tolerances; therefore,
an individual unit might not exactly match the listed
specifications. Also, this product is tested and cali-
brated under closely controlled conditions, and some
minor differences in performance can be expected if
those conditions are changed.
T8400C, T8401C, T8424C,D TRADELINE® models include a
thermostat, wallplate for wiring and mounting thermostat and
owner's guide.
T8400C, T8401C SUPER TRADELINE® models include a
thermostat, wallplate (for mounting and wiring thermostat),
two decorator cover plates for covering wall marks (3-7/8 in. x
3-7/8 in. and 5-3/4 in x 5-3/4 in.), and owner's guide.
Power:
T8400C: 24 Vac nominal, 18 to 30 Vac, 50/60 Hz.
T8401C: 24 Vac nominal, 18 to 30 Vac, 50/60 Hz.
T8424C,D: 24 Vac nominal, 18 to 30 Vac, 50/60 Hz.
Electrical Ratings:
Heating: .02 to 1.5A run; 3.5A inrush.
Cooling: .02 to 1.5A run; 7.5A inrush.
Fan: .02 to 0.5A run; 2.5A inrush.
Current Draw:
T8400C Power Stealing Thermostat requires less than
0.25 mA current draw when the thermostat calls for heat
and is compatible with most 24V microprocessor systems.
The T8400C Power Stealing Thermostat can be used in
any non-millivolt application where the T8401C and
T8424C,D Hard Wired Thermostats cannot be used. For
further detail, see Power Stealing in the Operation section.
Temperature Adjustment:
Setpoint temperature is adjusted by using the
keys. One press changes the setpoint one degree; press-
ing and holding changes the setpoint several degrees.
Temperature Setting Range: 40°F (4°C) to 99°F (37°C).

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the
TRADELINE® Catalog or price sheets for complete ordering number.
If you have additional questions, need further information, or would like to comment on our products or services, please write or
phone:
1. Your local Home and Building Control Sales Office (check white pages of your phone directory).
2. Home and Building Control Customer Relations
Honeywell, 1985 Douglas Drive North
Golden Valley, Minnesota 55422 (800) 468-1502
In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.
International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France,
Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.
68-0180-3
Ambient Temperature Range: 40°F (4°C) to 110°F (43°C).
Shipping Temperature Range: -20°F (-29°C) to 120°F
(49°C).
Operating Relative Humidity: 5% to 90% RH, non-
condensing.
Cycle Rates (at 50% Load):
Heating: Selectable at 1, 3, 4, 5, 6, 9 or 12 cph. See Table
1 for cycle rate options and corresponding system
equipment.
Cooling: Fixed at 3 cph.
Steam, gravity
Hydronic heat, condensing
gas furnaces
Special applications
Gas or oil forced air (default)
Electric heat
Special applications
a
High efficiency furnace.
b
Refer to equipment manufacturer's instructions.
Finish:
T8400C, T8401C and T8424C,D TRADELINE® AND SUPER
TRADELINE®: Taupe finish.
T8400C, T8401C and T8424C,D STANDARD MODELS:
Premier White® finish and only available in builder packs of
20.
or
Accessory: Decorator cover plates (for covering wall marks):
5-3/4 in. x 5-3/4 in. and 3-7/8 in. x 3-7/8 in.
Dimensions: See Fig. 1 or 2.
2
Table 1. Heating Cycle Rates.
System
a
b
b
Cycles Per Hour
1
3
4, 5
6
9
12