Summary of Contents for AEG 835 D

  • Page 1 835 D / 8359 D Dunstabzugshaube Fume Extractor Hood Afzuigkap Montage- und Gebrauchsanweisung Installation and Operating Instructions Montage- en gebruiksaanwijzing...
  • Page 2: Table Of Contents

    Installation Hood Operation Safety warnings for user Maintenance and care Metal grease filter Open the metal grease filter Carbon filter Changing the light bulb Cleaning Special accessories Technical assistance service Printed on recycled paper. AEG – putting words into action.
  • Page 3: Introduction

    The hood is supplied as an extractor unit and can also be used with a filtering function by fitting activated carbon filters (special accessory). You will need original AEG activated carbon filters for this function (see Special Accessories). The air is forced out through a hose fitted to the top of the hood A.
  • Page 4: Filter Version

    The air is filtered through an activated carbon filter and passed back into the kitchen through the top outlet duct grids. You will need an original AEG KF 825 activated carbon filter for the filtering function. (See Special Accessories). Fix the deflector with two screws Ø3,5x6,5. Fig. 2.
  • Page 5: Electrical Connections

    Electrical connections Safety warnings for electrician It must be ensured that the voltage and current indicated on the rating plate agree with the voltage of the user to electricity supply. If the appliance has been equipped with a mains lead with a moulded-on type plug, the following regulations must be comply with: The plug moulded on to the lead incorporates a fuse.
  • Page 6: Appliances With 2 Wires

    Electrical connection for the UK Appliances with 2 wires The appliance must be connected to fixed wiring with a double pole switched fused spur outlet with or without pilot lamp. We strongly recommend the appliance to be connected only by a qualified electrician who is a member of the NICEIC who will comply with the IEE and any local regulations.
  • Page 7: Technic Details

    Technic Details Dimensions (835 D): Height x Width x Depht (in cm) 84-117 x 59,9 x 51.5 Dimensions (8359 D): Height x Width x Depht (in cm) 84-117 x 89,9 x 51.5 Maximum absorbed power: 185W Motor absorption: 1 x 160 W...
  • Page 8: Installation

    Installation Safety warnings for kitchen unit installer When used as an extractor unit, the hood must be fitted with a 150mm diameter hose. If the fumes must be forced out through the wall, you must obtain a MKZ sizable wall exhaust pipe (with external exhaust and air intake), E-Nr.- 942 118 609 (Ø...
  • Page 9 a chimney if the room and/or flat (air/environment combina- tion) is ventilated from outside using a suitable ventilation hole approximately 500-600 cm large to avoid the possibility of a depression being created during operation of the hood. If you have any doubts, contact the relevant controlling authority or building inspector’s office.
  • Page 10: Installation

    Installation - Fig. 3 Put the template onto the wall (1) and drill two Ø12mm holes (2). Fit two hooks (3) on the drilled holes. Hang the hood on the hooks and adjust the position of the hood using the two screws on the bottom of the hooks (5). Remove the metal filters (4) and mark two points (6).
  • Page 11 Fig. 3...
  • Page 12: Hood Operation

    Hood Operation The hood is fitted with a variable speed motor. The most effective use of the hood is obtained by switching it on a few minutes before you start cooking and leaving it on a for approximately 15 minutes after you have finished, thus ensuring all cooking odours are eliminated.
  • Page 13: Safety Warnings For User

    Safety warnings for user Never leave a cooking hob or ring on without a pot or pan on top of it, to avoid the possibility of excess heat damaging the unit. Gas, oil or coal cooker flames in particular should never be left uncovered. Special care should be taken when using deep fat fryers since the oil in them can overheat and burst into flames.
  • Page 14: Maintenance And Care

    Maintenance and care The hood must always be disconnected from the mains power supply before beginning any maintenance work. Metal grease filter The purpose of the grease filters is to aspirate grease particles which form during cooking and it must always be used, either in the external evacuation or internal recycling function.
  • Page 15: Carbon Filter

    The activated carbon filter should only be used if you want to use the hood in its filtering function. To do this you will need an original AEG activated carbon filter (see special accessories). This filter cannot be cleaned or reused.
  • Page 16: Changing The Light Bulb

    Warning Failure to observe the instructions on cleaning the unit and changing the filters will cause a fire hazard. You are therefore strongly recommended to follow these instructions. The manufacturer declines all responsibility for any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations.
  • Page 17: Cleaning

    Cleaning Warning: always disconnect the hood from the mains power supply before cleaning it. Never insert pointed objects in the motor’s protective grid. Wash the outside surfaces using a delicate detergent solution. Never use caustic detergents or abrasive brushes or powders.