Electrolux FGH50K2-41 User Manual page 70

Electrolux cooker
Table of Contents

Advertisement

Available languages

Available languages

70 electrolux
Minimal distances
Dimension
A
B
C
Technical Data
Appliance class 2, sub class 1 and class 1.
Dimensions
Height
Width
Depth
Total electricity power
Voltage
Gas burners
Burner
Normal
power
kW
Auxiliary
1,00
burner
1,00
0,85
Semi-rapid
1,90
burner
2,00
1,70
Rapid burn-
3,00
er
3,00
2,60
Oven
2,70
2,50
2,15
Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with
the regulation in force. If you use flexible
metallic pipes, be careful they do not come
in touch with mobile parts or they are not
squeezed.
When you install and connect the appli-
ance, obey the directives:
• SVGW- Gas principles G1: Gas in-
stallation
mm
690
150
20
855 mm
500 mm
600 mm
15,6 W
230 V
Reduced
Type of gas
power
kW
0,35
Natural Gas
G20
0,35
Butane G30
0,31
Propane G31
0,45
Natural Gas
G20
0,43
Butane G30
0,40
Propane G31
0,75
Natural Gas
G20
0,72
Butane G30
0,63
Propane G31
0,90
Natural Gas
G20
1,00
Butane G30
0,78
Propane G31
Frequency
Gas Category
Gas Supply
By-pass diameters
Burner
Auxiliary
Semi-rapid
Rapid
Oven
Pres-
Inj. Diam-
sure
mbar
20
50
50
20
50
50
20
50
50
20
50
50
• EKAS- Form. 1942: Liquid gas direc-
tive, Part 2
• Cantonal instances regulations (e.g.
fire safety regulators)
Flexible nonmetal pipes connection
If it is possible to easily control the connec-
tion in its full area, you can use a flexible
pipe. The flexible pipe must be tightly at-
tached by clamps.
50 Hz
II2ELL3B/P
G20(2E) 20 mbar
G30/G31 (3B/P)
50/50 mbar
Ø By-pass in 1/100
mm.
26
28
38
39
Cons.
eter
mm
g/h
0,70
-
0,43
72,71
0,43
60,70
0,96
-
0,60
145,43
0,60
121,40
1,19
-
0,77
218,14
0,77
185,68
1,20
-
0,63
181,78
0,63
153,54

Advertisement