Samsung SCB-3003 User Manual

Supreme resolution wdr camera

Advertisement

Quick Links

Supreme Resolution
WDR Camera
User Manual
SCB-3003

Advertisement

Table of Contents
loading

Summary of Contents for Samsung SCB-3003

  • Page 1 Supreme Resolution WDR Camera User Manual SCB-3003...
  • Page 2: User Manual

    Samsung Techwin. Disclaimer Samsung Techwin makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user’s own responsibility.
  • Page 3 Before operating the camera, confirm the camera model and correct input power voltage. To help you understand this manual thoroughly, we'll introduce our model description. ■ SCB-2002 SERIES • NTSC MODEL • PAL MODEL SCB-3003N SCB-3003P ■ MODEL DESCRIPTION • SCB-3003X _ SIGNAL SYSTEM •...
  • Page 4: Safety Information

    safety information CAUTION RISK OF ELECTRIC SHOCK. DO NOT OPEN TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE CAUTION: COVER (OR BACK) NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. This symbol indicates that dangerous voltage consisting a risk of electric shock is present within this unit.
  • Page 5: Personal Injury

    fi re or electric shock. If this product fails to operate normally, contact the nearest service center. never disassemble or modify this product in any way. (samsung is not liable for problems caused by unauthorized modifi cations or attempted repair.) When cleaning, do not spray water directly onto parts of the product.
  • Page 6: Fcc Statement

    safety information FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions : This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation.
  • Page 7: Important Safety Instructions

    Apparatus shall not be exposed to dripping or splashing and no objects fi lled with liquids, such as vases, shall be placed on the apparatus Samsung Techwin cares for the environment at all product manufacturing stages to preserve the environment, and is taking a number of steps to provide customers with more environment-friendly products.The Eco mark represents...
  • Page 8: Table Of Contents

    contents INTRODUCTION Features Components and Accessories Overview Lens CONNECTION Connecting to Monitor Connecting to Power Control via RS-485 Interface Using Coaxial Communications CAMERA OPERATION Menu Confi guration Menu Setup TROUBLESHOOTING Troubleshooting SPECIFICATIONS Specifi cations Dimension 8_ contents...
  • Page 9: Introduction

    Without assistance from an external sensor, this camera independently detects and traces objects while examining stillness and movement to activate the alarm. SSNR3 (Samsung Super Noise Reduction) Function High performance SV-V DSP Chip removes noises of GAIN resulting from the low light level and shows a vivid, high defi...
  • Page 10 Communication Coaxial and RS-485 communication methods are supported. - Coaxial Communications : Pelco Coaxitron - RS-485 Communications : Samsung-T, Samsung-E, PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, GE, AD The camera’s OSD is complimented by 19 languages. - NTSC : English, Korean, Japanese, Spanish, French, Portuguese...
  • Page 11: Components And Accessories

    Components and Accessories Check if the following items are included in the product package. Auto Iris Lens SCB-3003 C-Mount Adapter Connector Plug Supreme Resolution WDR Camera Quick Guide SCB-3003 Quick Manual 10 level terminal block Overview Front View Tripod Mounting Bracket Screw Hole : Used to fi...
  • Page 12: Side View

    introduction Side View Auto Iris Lens Connector : Used to connect Auto Iris Lens plug. Bottom View Tripod Mounting Bracket Screw Hole : Used to fi x the camera on a bracket or tripod. The screw sizes for this hole are as follows. 1/4"-20 UNC (20 THREAD) L:4.5mm±0.2mm (ISO standard), or 0.197"...
  • Page 13: Rear View

    Rear View Function Setup Button SET button : (Short press) The SIMPLE FOCUS operates. (Long press) The menu screen is displayed. Use it to go the lower menu on the menu screen. Up & Down button : Used to move the cursor up or down in the menu screen. Left right button : Move the cursor left and right on the menu screen.
  • Page 14 introduction D & N Input Port : You can switch to Day & Night Mode by connecting an external signal to this port. MD Output Port : Motion detection signals are output through this port. Video OUT Terminal : Sends video signal and connects to the video input terminal of the monitor. Power LED : This lamp is lit when the camera is receiving power normally.
  • Page 15 Lens The lens is not supplied with this camera. Purchase a lens suitable for your environment. This camera accepts the auto iris lens and both C-and CS-mount lens.  To use the functions of this camera effectively it is recommended that a DC type Auto Iris lens is used. ...
  • Page 16 introduction Fit the cover of the auto iris lens connector plug, remove the protective glass cover from the front of the camera, and fasten the auto iris lens by turning it clockwise. Combine the lens and adjust the focus manually fi rst. Then use SIMPLE FOCUS to easily adjust the focus.
  • Page 17  Use the lens connector shown in the following fi gure. If the dimensions of the connector are not correct, it may damage the camera, or the lens may not be installed fi rmly.  If the lens is too heavy, the camera becomes unbalanced and there may be problems.
  • Page 18: Connection

    connection Connecting to Monitor Connect the Video OUT port on the rear panel of the camera to a monitor. CCD Camera Monitor As the connecting method varies with the instruments, refer to the manual supplied with the instrument. Only connect the cable when the power is turned off. Connecting to Power Since power specifications differ depending on the model, make sure to check your model name and specifications before connecting power.
  • Page 19: Camera Operation

    * RS-485 Communication establishment initial value Item Camera ID BAUD RATE UART MODE RET PKT Initial value 19200 8-NONE-1 ENABLE  To control the camera by constructing an additional controller, use the SAMSUNG-T, SAMSUNG-E, PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON and PANASONIC, GE, AD protocol. English_19...
  • Page 20: Specifications

    connection Using Coaxial Communications Coaxial Communications System OSD Control method If you set the sensitivity level of the sub menu item (of COAX) to “Low”, you have to press the MENU/ENTER (OSD KEY) button twice in a row to access the OSD menu. (To prevent an error by noise from the DVR) CAMERA CONTROLLER...
  • Page 21: Menu Confi Guration

    camera operation Menu Configuration MAIN SETUP LENS VIDEO MANUAL ● ● ● BRIGHTNESS SHUTTER ● ● ● EXPOSURE SENS-UP RETURN ● ● ● ATW ● OUTDOOR ● INDOOR WHITE BAL ● MANUAL ● AWC SET ● ● USER BLC ● BACKLIGHT SSDR ●...
  • Page 22 camera operation Main SETUP menu is displayed on the monitor screen. MAIN SETUP Select the Change the status by 1. LENS function using moving the setup 2. EXPOSURE switch left or right. the Function 3. WHITE BAL Setup button 4. BACKLIGHT 5.
  • Page 23 Brightness (DC, Manual) : Adjusts the video brightness. Level (VIDEO) : Adjusts the level of video iris signals; the higher the level, the brighter the video looks. FOCUS ADJ (DC, VIDEO) : To correctly adjust the focus of LENS, activate the focus setup mode located at the bottom of each lens menu.
  • Page 24 camera operation EXPOSURE When the SETUP menu screen is displayed, select ‘EXPOSURE’ by using the Function MAIN SETUP Setup button so that the arrow indicates 1. LENS ‘EXPOSURE’. 2. EXPOSURE 3. WHITE BAL Select a desired mode using the Function Setup button.
  • Page 25  When you use a DC lens, set the shutter mode to --- if color rolling occurs.  When the SHUTTER is set to ESC after selecting the Internal Synchronization Type, the picture may become unstable if the camera faces a bright fl uorescent light. Therefore, take care when choosing the installation position.
  • Page 26 camera operation White Bal (White Balance) Use the White Balance function to adjust the screen color. When the SETUP menu screen is displayed, MAIN SETUP select ‘White Bal’ by using the Function 1. LENS Setup button so that the arrow indicates 2.
  • Page 27 BACKLIGHT The SCB-3003 is designed so that it delivers a distinctive subject and background at the same time, even when the subject is in backlight, by adopting a function of the proprietary SV-V DSP chip. When the SETUP menu screen is displayed, MAIN SETUP select ‘BACKLIGHT’...
  • Page 28 SSDR (Samsung Super Dynamic Range) : SSDR illuminates darker areas of an image while SSDR SETUP retaining the same light level for brighter areas to even out the overall brightness of images with 1. LEVEL high contrast between bright and dark areas.
  • Page 29  Because there can be a difference in the effectiveness of HLC according to the amount of light area in the screen, optimize the installation angle for the best HLC performance.  When dark, the HLC is only activated when a bright light exceeding a specifi c size. (In NIGHT ONLY mode).
  • Page 30 camera operation DAY/NIGHT You can display pictures in color or in black and white. When the SETUP menu screen is displayed, MAIN SETUP select ‘DAY/NIGHT’ by using the Function 1. LENS Setup button so that the arrow indicates 2. EXPOSURE ‘DAY/NIGHT’.
  • Page 31 PROFILE When the SETUP menu screen is displayed, MAIN SETUP select ‘PROFILE’ by using the Function 1. LENS Setup button so that the arrow indicates 2. EXPOSURE ‘PROFILE’. 3. WHITE BAL 4. BACKLIGHT 5. SSNR3 6. DAY/NIGHT AUTO 7. PROFILE BASIC 8.
  • Page 32 SPECIAL When the SETUP menu screen is displayed, MAIN SETUP select ‘SPECIAL’ by using the Function 1. LENS Setup button so that the arrow indicates 2. EXPOSURE ‘SPECIAL’. 3. WHITE BAL 4. BACKLIGHT 5. SSNR3 6. DAY/NIGHT AUTO 7. PROFILE BASIC Select a desired mode using the Function 8.
  • Page 33 VPS(Virtual Progressive Scan) : This is an advanced technology that reproduces a sharp progressive image. This is appropriate to high quality recording and file transfer via the Internet. • OFF : Selects 2:1 Interlaced Scan as the Imaging Method. • ON : Selects Progressive Scan as the Imaging Method.
  • Page 34 camera operation Press the set button. Use the Function Setup button to move to a desired letter and select the letter by pressing the set button. Repeat this to enter multiple letters. You can enter up to 15 letters. Enter a title, move the cursor to ‘POS’ and press FRONT DOOR the set button.
  • Page 35 INTELLIGENCE : Commands the camera to motion-detect and INTELLIGENCE trace an object. 1. MOTION MOTION : Select motion types to detect. 2. DETECT BOX 3. ALARM OUT • OFF : Not being used. 4. DETECT AREA 5. MASK AREA • DETECTION : Since the camera 6.
  • Page 36 camera operation AREA FENCE SEL POS : Selects a position from AREA FENCE POS1 ~ POS4. 1. SEL POS POS1 X POS / Y POS : Adjust the size 2. X POS and position of the selected area 3. Y POS fence.
  • Page 37 • RETURN : Select this to save the MASK AREA menu settings and return to the INTELLIGENCE menu. SENSITIVITY : Set the sensitivity of the motion detection. When you adjust the lower level, the more sensitive. DETECT SIZE : Selects an object size to detect on the screen. When you adjust higher levels, the more larger size.
  • Page 38 DISP ID : Display camera title on top left corner of the screen. PROTOCOL : Select the communication PROTOCOL. (SAMSUNG-T, SAMSUNG-E , PELCO-D, PELCO-P, BOSCH, HONEYWELL, VICON, PANASONIC, GE and AD) COAX : You can select whether to use COAX communication.
  • Page 39: Troubleshooting

    troubleshooting Troubleshooting If you have trouble operating your camera, refer to the following table. If the guidelines do not enable you to solve the problem, contact an authorized technician. Problems Troubleshooting Nothing appears on the screen. Check that the power cord and line connection between the camera and monitor are properly connected.
  • Page 40: Specifi Cations

    specifications Specifications SCB-3003N SCB-3003P Video 1/3 Super HAD CCD II (Double Scan) Imaging Device Total Pixels 1,028(H) x 508(V) 1,028(H) x 596(V) Effective Pixels 976(H) x 494(V) 976(H) x 582(V) Scanning System 2:1 Interlace Synchronization Internal / Line-Lock / Extern Frequency H : 15.734KHz / V : 59.94Hz H : 15.625KHz / V : 50Hz...
  • Page 41 Off / On Alarm 1 Out Communication Coaxial Control, RS-485 Coax : Pelco-C (Coaxitron) Protocol RS-485: Samsung-T, Samsung-E, Pelco-D, Pelco-P, Panasonic, Bosch, Honeywell, Vicon, GE, AD Environmental Operating Temperature -10°C ~ +55°C / Less than 90% RH / Humidity Electrical Input Voltage Dual ( 24VAC±10% &...
  • Page 42: Dimension

    Dimension Unit: mm 42_ specifi cations...
  • Page 43 MEMO...
  • Page 44 SAMSUNG TECHWIN AMERICA Inc. SAMSUNG TECHWIN EUROPE LTD. 100 Challenger Rd. Suite 700 Ridgefield Park, NJ 07660 Samsung House, 1000 Hillswood Drive, Hillswood Business Park Toll Free : +1-877-213-1222 Direct : +1-201-325-6920 Chertsey, Surrey, UNITED KINGDOM KT16 OPS Fax : +1-201-373-0124 TEL : +44-1932-45-5300, FAX : +44-1932-45-5325 www.samsungcctvusa.com...

This manual is also suitable for:

Scb-2002 seriesScb-3003nScb-3003p

Table of Contents