3. Connecting to the DMX512 Network

Basic DMX512 installation consists of connecting multiple SL STRIP 400 TW LED Luminaires together (up to 32
luminaires) in "daisy-chain" fashion. A cable runs from the control console (or DMX512 control source) to the DMX
connector on the first SL STRIP 400 TW LED Luminaire. Another cable runs from the other DMX connector on the
first unit to a DMX connector on the next SL STRIP 400 TW LED Luminaire (or DMX512 device to be controlled).
DMX512 / RDM Input
Bottom of Unit
Note: For more information on DMX512 networking and systems, refer to
page
1. For SL STRIP 400 TW LED Luminaire DMX Mapping, refer to
DMX512
(from console or
control device)
8
INSTALLATION AND SET UP
Figure 4: SL STRIP 400 TW LED Luminaire DMX512 Input / Output Connections
DMX512
(out from first
to second luminaire)
SL STRIP 400 TW
LED Luminaires
Figure 5: SL STRIP 400 TW LED Luminaire - DMX512 Connections
SL STRIP 400 TW LED Luminaires
"Additional Resources for DMX512" on
"DMX CONTROL" on page
DMX512 Connections
DMX512 Signal
Common (Drain)
DMX512 -
DMX512 +
Note: Remaining pins on each connector are not used.
DMX512
(out to the next
luminaire or DMX512
controlled device)
DMX512 / RDM Output
17.
XLR Pin
1
2
3
Sh wline