Configuration & Service Data; Configuration Data (To Be Completed By Installer) - Honeywell Y9120H Sundial RF2 Pack 1 User Manual

St9120c wireless enabled timer and dt92e wireless room thermostat
Hide thumbs Also See for Y9120H Sundial RF2 Pack 1:
Table of Contents

Advertisement

CONFIGURATION & SERVICE DATA

Configuration Data (to be completed by Installer)

The tables below are for the Installer to complete to indicate how your ST9120C and
DT92E have been configured.
Configurable Features
ST9120C Configuration
24hr or am/pm clock
display.
Display backlight operation. Off
Automatic time change.
1-day or 5/2-day or 7-day
operation.
Number of ON/OFFs per
day.
Default time programme.
Hot water set temperature
Optimum start
Optimum start limit
Optimum stop
Frost protection temperature From 5 to 16°C
Minimum ON/OFF time
Cycle rate
Proportional band width
DT92E Configuration
Failsafe mode (loss of RF
communications)
Measurement offset
Upper setpoint limit
Lower setpoint limit
Energy saving ECO setpoint
30
Options
am/pm display
24hr display
on if button pressed
on continuously
disabled,
enabled
1-day operation
5/2-day operation
7-day operation
2 on/offs per day,
3 on/offs per day
A = standard
b = at home
C = economy
From 40 to 85°C
no optimum start
delayed start
optimum start on
1 hour
2 hours
3 hours
disabled
enabled
1, 2, 3, 4, 5 minutes
3, 6, 9, 12 cycles
per hour
From 1.5 to 3.0°C
off
on 20%
-3.0°C to 0 to 3.0°C
21 to 35°C
5 to 21°C
5 to 35°C
Factory
Installer configured
setting
(tick box or note value)
50°C
5°C
1 minute
6 cycles
1.5°C
0
35°C
5°C
18°C
50047645-001 A

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents