Casio DT-81D User Manual page 33

Data collector
Table of Contents

Advertisement

1
RS-232C connector
2
RS-422 connectors
3
AC adaptor jack
4
Data Collector detection switch Detects whether or not the Data Collector is mounted correctly on
5
Charge/Power supply terminal
6
System operation indicator
7
Data communication indicator
8
Charge indicator
9
Power indicator
10 Infrared port
11 Power switch
12 Base
13 DIP switches
14 Wall mounting tab
15 Wall mounting hole
For connection of a PC and uploading/downloading of system data
and file data.
For connection of multiple optional Optical Communication Units.
For connection of an AC adaptor to supply power.
the Optical Communication Unit.
Supplies power to the Data Collector mounted on the Optical
Communication Unit.
Indicates whether or not the system operation is normal. A system
operation problem is indicated when this indicator does not light up
green shortly after the Data Collector is mounted onto the Optical
Communication Unit.
Off: All Data Collectors mounted on the Optical Communication
Units are unable to communicate, or there is a system problem.
Lit Green: Normal system operation. One or more of the Data
Collectors mounted on the Optical Communication Units are
communicating.
Indicates the status of data communication operations.
Off:
Not communicating
Flashing Green: Communication in progress
Lit Red:
Optical Communication Unit connection problem
Indicates the charge status of the lithium-ion battery pack.
Off:
Not charging (Data Collector battery compartment
contains alkaline batteries)
Lit Red:
Charging
Lit Green:
Charging complete
Flashing Red:
Battery pack problem
Flashing Green: Charging interrupted because ambient
temperature is outside of allowable range for
charging. Charging will resume when temperature
is back within the allowable range.
Indicate whether power is on or off, and if the Data Collector is
mounted.
Off:
Power off
Red:
Power on, Data Collector not mounted
Green: Power on, Data Collector mounted
This port provides contact-less infrared communication capabilities
with a Data Collector.
Turns power on and off.
Reverse the position of the base when wall mounting the Optical
Communication Unit.
Use these switches to set the operational configuration of the
Optical Communication Unit.
Secures the Data Collector when mounting it on a wall.
Use this hole to attach the Optical Communication Unit to a hook
on a wall.
E-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dt-810

Table of Contents