● DNS
Select "MANUAL" or "AUTO" to enable searching an IP
address by its host name using DNS. When "OFF" is select-
ed for "DHCP" (no use of the DHCP server), select "MANU-
AL" and enter the domain name and the DNS server
address. If "ON" is selected for "DHCP" (use of the DHCP
server), select "AUTO". When DNS is not used, select "OFF".
When "MANUAL" is selected for DNS, enter the DNS server
address for "Primary" and "Secondary".
● DDNS
Select ON and OFF whether or not to use the DDNS
(Dynamic Domain Name Server).
Selecting ON is available only when "MANUAL" or "AUTO" is
selected for "DNS".
When "ON" is selected, perform the following.
User Name: Enter the user name registered in "DDNS".
Password: Enter the password for the user entered in
"User Name".
Access Interval: Select an interval to update DNS from the
following.
10 m/30 m/1 h/6 h/24 h
● Host Name
Enter the host address registered in DDNS.
Enter a host name of no more than 255 alphanumeric char-
acters. Hyphens (-) are also available for the host name.
● Domain Name
Enter the domain name of this unit.
Enter a domain name of no more than 255 alphanumeric
characters. Hyphens (-) are also available for the domain
name.
u
[NTP Setup] Time adjustment of network
Perform the following settings for time adjustment.
SETUP MENU
Maintenance
Recording
Switcher
Display
■
Camera Control
Time Adjustment
■
Time Zone
PS.DATA Setup
■
NTP Server Address
RS485 Setup
■
RS232C Setup
Refresh Interval
NW Setup 1
NW Setup 2
NTP Setup
● Time Adjustment
Select ON and OFF whether or not to adjust the time with
reference to the NTP server.
ON: Adjusts time with reference to the NTP server.
OFF: Does not function.
● Time Zone
Set the time zone in accordance with the place of use when
using the NTP server for time adjustment.
Event
Schedule
LIVE
Comm
System
OFF
GMT+11:00
GMT-5:00
6h
● NTP Server Address
Enter the NTP server address when using the NTP server
for time adjustment.
● Refresh Interval
Select an interval of time inquiry to be transmitted to the
NTP server from the following.
1 h/2 h/6 h/12 h/24 h
Important:
Recording will not be performed for around 4 seconds
when changing the present time (accurate within ±5
seconds) using "Time Adjustment".
119