Temperature: Observe the unit's ambient temperature specifications when
choosing a location for the unit. Extremes of heat or cold beyond the specified
operating temperature limits may cause the unit to fail. Do not install this unit on
top of other hot equipment.
Moisture: Do not expose the unit to rain or moisture. Moisture can damage
internal components. Do not install this unit near sources of water.
RS485 Limitations: Total length of the RS-485 network is limited to 3000'.

1.4 Power

The ProBridge is furnished with a power supply (110 or 240 VAC). Do not use
any other power supply with this product. The manufacturer accepts no
responsibility for damage caused by the use of any other power supply.
Make sure installation is complete and all connections are made before applying
power to the unit.
Voltage: 120 Volt AC
Tolerance: ±10%
Frequency: 60 Hz
Voltage: 12 Volt DC
Current: 110mA
Power: 1.3 Watts
Connector: 2.1mm female barrel. Center Positive
Voltage: 220 Volt AC
Tolerance: ±10%
Frequency: 50 Hz
Voltage: 12 Volt DC
Current: 110mA
Power: 1.3 Watts
Connector: 2.1mm female barrel. Center Positive
Philips ProBridge
4310-0007 120VAC Power Supply
Power Supply Input
Power Supply Output
4310-0008 220VAC Power Supply
Power Supply Input
Power Supply Output