Alert Message
number > failed.
Virtual Disk <
number > has an invalid layout.
Virtual Disk <
device > failed.
<
device > is missing.
<
device > has failed.
Storage <
device > is missing.
Storage <
NVRAM Alerts
NVRAM PCI Controller failed.
NVRAM PCI Controller is missing.
Super Capacitor on the NVRAM PCI Controller failed.
Super Capacitor on the NVRAM PCI Controller is missing. Replace the NVRAM PCI Controller.
Failed to check software compatibility.
154
Description/Meaning or Action
If this is seen on a single physical disk, the foreign
configuration should be cleared.
NOTE: This condition can also be seen when a drive is
removed and reinserted while a rebuild is still in
progress.
Replace any failed or missing physical disk(s) and run the
Dell Restore Manager (RM) utility.
Run the Dell Restore Manager (RM) utility to repair this
installation.
Verify that the device is present, and then check
that the cables are properly connected. For more
information, see the
Owner's Manual to verify the system cabling is
correct.
Check the connection to the controller battery and
the status of battery health.
If none of these steps resolve the problem, replace
the storage controller battery.
Verify that the device is present, and then check
that the cables are properly connected. For more
information, see the
Owner's Manual to verify the system cabling is
correct.
Check the connection to the controller battery and
the status of battery health.
NOTE: A battery with a weak or depleted charge can
cause this warning.
Check cable connections between the storage controller
and the enclosure or backplane.
Perform the following:
Check SAS and power cable connections between
the storage controller and the enclosure or
backplane.
Check the external enclosure management
modules (EMM) and PERC status LEDs.
Replace the NVRAM PCI Controller.
Reinsert or replace the NVRAM PCI Controller.
Replace the NVRAM PCI Controller.
Upgrade the DR Series system appliance (in the Software
Upgrade page, click Start Upgrade).