NEC Express5800/320Fd-LR User Manual

Nec servers user's guide
Hide thumbs Also See for NEC Express5800/320Fd-LR:
Table of Contents

Advertisement

Quick Links

N8800-122F/132F, EXP320J
NEC Express5800/320Fd-LR
N8800-123F/133F, EXP320K
NEC Express5800/320Fd-MR
User's Guide (Setup)
4th Edition
10-2008
856-127506-102-D

Advertisement

Table of Contents
loading

Summary of Contents for NEC NEC Express5800/320Fd-LR

  • Page 1 N8800-122F/132F, EXP320J NEC Express5800/320Fd-LR N8800-123F/133F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 4th Edition 10-2008 856-127506-102-D...
  • Page 2 The NEC product(s) discussed in this document are warranted in accordance with the terms of the Warranty Statement accompanying each product. However, actual performance of each such product is dependent upon factors such as system configuration, customer data, and operator control.
  • Page 3 Keep this User's Guide handy for quick reference when necessary. Safety Indications To use NEC Express5800 series safely, follow the instructions in this User's Guide. This guide explains components that pose a danger, types of dangers caused by failing to follow the instructions, and actions taken to prevent them;...
  • Page 4 Symbols and its descriptions used in this User’s Guide and warning labels are as follows: Attention Indicates a risk of an electric shock. Indicates a risk of a personal injury due to heat. Indicates a risk of catching your fingers. Indicates a risk of a fire or smoke.
  • Page 5 Mandatory actions Unplug the server. There is a risk of an electric shock or fire. Indicates a general action to take that is not defined herein. Make sure to follow the instructions. For detailed notes to set up the machine safely, refer to “NOTES FOR SAFE HANDLING” on page 1-2.
  • Page 6 安全注意事項 安全標示 請參考本用戶指南中的指示以安全使用NEC Express5800系列伺服器。 本用戶指南說明了設備何處有危險、危險類型、如何避免危險等。在設備可預計到的危險之處或其附近 貼有警告標籤。 用戶指南及警告標籤中,根據危險程度不同,使用“警告"、“注意"等詞,含義如下: 表示如不遵守該指示,可能引發人員傷亡。 WARNING 表示如不遵守該指示,可能發生燒傷等身體損傷或造成物質損失。 CAUTION 對危險的提示表示有如下三種符號,具體含義如下所述: 表示該處可能發生危險。符號為危險內容的圖案。(注意) 表示禁止行為。符號中或其附近的圖案為禁止行為內容。(禁止行為) 表示強制行為。符號中的圖案為強制必須做的行為內容。即為避免危險必需的行為。 (強 制行為) (用戶指南中範例) 注意符號 表示危險程度的用語 CAUTION 注意高溫。 本產品關閉電源後,內置硬碟等內部設備仍然處於高溫狀態。請在充分冷卻之後 進行拆裝。 禁止行為的提示符號(有可能沒 危險提示內容 有此類提示)...
  • Page 7 本書及警告標籤中使用的符號 注意 表示有觸電的危險。 表示有因高溫而負傷的危險。 表示有手指等被夾住的危險。 表示有冒煙或者著火的危險。 表示非特定的一般的提醒警告。 表示有因雷射導致失明的危險。 表示有爆炸的危險。 表示有受傷的危險。 禁止行為 表示非特定的一般禁止。 不要觸摸指定區域。有觸電或著火的危險。 不要用濕手觸摸。有觸電的危險。 遠離火源。有著火的危險。 遠離液體。如果沾到液體,有觸電或著火的危險。 請不要對本設備進行拆卸、修理、改造。有觸電和發生火災的危險。...
  • Page 8 強制行為 請將本設備的電源插頭從伺服器上拔下。有發生火災和觸電的危險。 對非特定的一般使用者的行為進行指示。請按照說明進行操作。 這是CLASS 1 LASER PRODUCT。該標籤貼於系統的內部光碟。 CLASS 1 LASER PRODUCT 注意: 本產品通過多餘的硬體模組提供硬體容錯性能。但是這並不表示能夠保證完全容錯。 如,在以下情況下可能發生宕機: – 軟體發生致命故障。 – 多餘硬體雙方均發生故障,不能運行。 – 時鐘產生器線路或內部連接背板等非多餘元件發生致命故障。 – 切斷了整個系統的AC電源...
  • Page 9 Trademarks and Patents NEC EXPRESSBUILDER, NEC ESMPRO and DianaScope are registered trademarks of NEC Corporation. Microsoft, Windows, Windows Server, Windows NT, and MS-DOS are registered trademarks of Microsoft Corporation in the United States and other countries. Intel and Pentium are registered trademarks of Intel Corporation.
  • Page 10 (5) NEC assumes no liability arising from the use of this product, nor any liability for incidental or consequential damage arising from the use of this manual regardless of (4) above.
  • Page 12: Preface

    “high performance,” “scalability,” and “general versatility” provided by NEC Express5800 series. In the event of trouble, its dual configuration will allow the system to instantaneously isolate the failed parts to assure non-stop running; operation will be moved smoothly from one module to the other, minimizing damage to it.
  • Page 13: About This User's Guide

    Something you need to make sure when using the server or software Helpful information, something useful to know TIPS: About our Web Service Information on NEC Express5800/ft series including modification modules is also available on our web site, NEC Express5800 Web Site Asia Pacific: http://www.nec.co.jp/express/index.html...
  • Page 14: 關於正式文本

    關於正式文本 使正式文本,是為了確實安裝本裝置,能使用的輔導。進行安裝的時候請利用。使正式文本 及另冊的用戶指南請經常放置在實體旁邊無論什麼時候能看。 正式文本,作為所說的關於 Windows 等的操作系統和鍵盤,鼠標的一般的輸入輸出設備等的 基本的處理有了充分的知識的用戶對象被記載。 正式文本讀方法 正式文本, 本裝置的購買後, 關於到能為止的系統的運用次序說明著。 如果做從 1 章順序讀, 隨著被記載的說明的操作,確實能安裝本裝置。4 章,如果把安裝被本裝置編入的操作系統與 (第一次把電源做為 ON 的時候的安裝次序)重新重新安裝操作系統的重新安裝(OS 的時候的安 裝次序)分成購買的時候說明著。安裝的目的合起讀請分開。5 章,說明著對安裝完成後必要 的各種工作的次序。還 6 章「故障嗎?想的時候」那麼,不能很好地安裝的情況的應對方法 被記載。本裝置的系統設定和有關修復的信息「系統的修復」(6-2 頁), 「安裝失敗了嗎?如果 有」隨心的事,請看「故障查找」(6-15 頁)。再者,卷末有索引。按照必要請有效的利用。 本裝置的運用和硬件及系統具體的機能·操作的說明請參照另冊的用戶指南。 關於本文中的記號 除了正式文本卷頭表現了的安全有關的注意記號以外使用著 3 種記號。變成這些的記號和意 義為理解,請確實處理裝置。 使用服務器或者軟件的時候預先記的重要的要點又指示 重要: 檢查: 需要你服務器或者使用軟件的時候,確實做(製作)的什麼 有用的信息,暗示...
  • Page 15: Table Of Contents

    Contents Preface..........................ii 開始............................ii About This User’s Guide....................iii How to Use This User's Guide..................iii Additional Symbols ......................iii About our Web Service..................... iii 關於正式文本 ........................iv 正式文本讀方法 ........................ iv 關於本文中的記號......................iv 關於正式文本的再購買...................... iv CHAPTER 1 BEFORE USING ..................1-1 在使用前 ..........................1-2 NOTES FOR SAFE HANDLING..................1-3 Warning Label ........................1-3 為了把有為了安全對待的注...
  • Page 16 Installing the device to the rack (N8140-74/92/93/94/98/99)......... 3-5 Unmounting the device from the rack (N8140-74/92/93/94/98/99) ......3-12 INSTALLING the Tower Conversion Kit (N8843-002) ..........3-13 Connect peripheral devices to NEC Express5800/ft series........3-18 CHAPTER 4 WINDOWS SETUP..................4-1 SETUP FLOW ........................4-3 Step 1: Procedure to Install and Reinstall OS ..............
  • Page 17 Step 8: Update Software ....................4-45 Step 9: Connect and Configure Options ..............4-46 Step 10: Create Volume ....................4-47 Step 11: Set Network for NEC ESMPRO Agent ............4-48 Step 12: Enable OS Boot Monitoring Function ............4-50 Step 13: Make Settings for Failure Management ............4-51 Set Memory Dump (Debug Information) ..............4-51...
  • Page 18 Installing ft Server Control Software ................6-13 TROUBLESHOOTING ....................6-15 Problems with NEC EXPRESSBUILDER ..............6-15 Problems with Windows Setup ..................6-16 Problems with Express Setup..................6-18 Problems with NEC ESMPRO Setup................6-19 Problems with System Repair..................6-20 APPENDIX A ABOUT SERVICES .................A-1...
  • Page 19: Chapter 1 Before Using

    Chapter 1 Before Using This chapter includes information necessary for proper and safe operation of the server, the main unit and its accessories. Go through this chapter before you start setup of the product.
  • Page 20: 在使用前

    1-2 Before Using 在使用前 為了把本裝置做為安全確實變成使用必要的關於信息,實體及附屬品等記載著。在安裝實體之前,必定 請讀。同時,關於本文中的名稱請參照用戶指南的「與各部分的名稱功能」的項...
  • Page 21: Notes For Safe Handling

    Before Using 1-3 NOTES FOR SAFE HANDLING The following section describes necessary information to use the product properly and safely. Warning Label Warning label is placed in the certain part of the system so that the user stays alert to possible risks. Do not remove or damage the label.
  • Page 22: 為了把有為了安全對待的注

    1-4 Before Using 為了把有為了安全對待的注 意的本裝置做為安全確實變成使用必要的信息被記載。 關於警告標籤 隱藏實體內的危險性的零部件和那個週邊警告標籤被粘貼。這個是為了請操縱本裝置的時候, 經常在顧客裡(上)認識能考慮的危險性的東西(揭下標籤,請別弄髒)。如果這個標籤沒被粘貼, 剝落懸掛著,髒等做不能辨認的時候購買的銷售店請聯絡。 對以下表現被本產品粘貼的標籤的位置。 設備前部...
  • Page 23: Precautions For Safety

    This equipment is not intended for use in controlling or use with facilities or systems where human lives are involved or high reliability is required, including medical devices or nuclear, aerospace, transportation, and traffic control facilities. NEC assumes no liability for any accidents or damage to physical assets resulting from the use of this equipment in such systems or facilities.
  • Page 24: Use Of Power Supply And Power Cord

    1-6 Before Using Use of Power Supply and Power Cord WARNING Do not handle power plugs with a wet hand. Do not plug/unplug power cords with a wet hand. There is a risk of an electric shock. Do not connect the ground wire to a gas pipe. Never connect the ground wire to a gas pipe.
  • Page 25: Installation, Relocation, Storage And Connection

    : sulfur dioxide, hydrogen sulfide, nitrogen dioxide, chlorine, ammonia and/or ozone. Avoid installing NEC Express5800/ft series in a dusty environment or one that may be exposed to corrosive materials such as sodium chloride and/or sulfur.
  • Page 26: Cleaning And Handling Of Internal Devices

    1-8 Before Using Cleaning and Handling of Internal Devices WARNING Do not disassemble, repair, or alter the server. Unless described herein, never attempt to disassemble, repair, or alter the server. There is a risk of an electric shock or fire as well as malfunction. Do not look into the DVD-ROM drive.
  • Page 27: During Operation

    Before Using 1-9 CAUTION Protect the unused connectors with the protective cap. The unused power cord connectors are covered with the protective cap to prevent short circuits and electrical hazards. When removing the power cord connector from the internal devices, attach the protective cap to the connector. Failure to follow this warning may cause a fire or an electric shock.
  • Page 28: Rack-Mount Model

    1-10 Before Using Rack-mount Model WARNING Do not install the server on a nonconforming rack. Install the server on a 19-inch rack conforming to the EIA standard. Do not use the server without a rack or install it on a nonconforming rack. The server may not function properly, and there is a risk of damage to physical assets or injuries.
  • Page 29 Before Using 1-11 CAUTION Do not install excessive wiring. To prevent burns, fires, and damage to the server, make sure that the rated load of the power branch circuit is not exceeded. For more information on installation and wiring of power-related facilities, contact your electrician or local power company. Do not pull out a device during operation.
  • Page 30: 安全注意事項

    1-12 Before Using 安全注意事項 本節講述安全使用本伺服器所需的注意事項。為了您正確安全地使用本伺服器,請仔細閱讀該節內容。 符號的相關說明請參考“安全標示(SAFETY INDICATIONS)"說明。 一般注意事項 WARNING 不要用於危及人命和需要高度可靠性的操作上。 本產品不要安裝在醫療設備、原子能設備、航空宇宙機器、運輸設備等會危及人 命以及需要高度可靠性的設備和機器上,也不要使用本產品來控制這些機器。如 果將本產品用於這類系統的設備及機器,造成人身事故及財產損失等後果,本公 司概不負責。 發生冒煙、異味、雜音時不要使用。 發生冒煙、異味、雜音等時,請直接關閉電源POWER,並將電源插頭從插座上拔 下。然後請與經銷商或維護服務公司聯繫。繼續使用會導致火災。 不要插入鐵絲和金屬片。 不要將金屬片和鐵絲等異物插入通氣孔或軟碟機、光碟機的縫隙。有觸電的危險。 CAUTION 在海外不使用。 本裝置,是日本國內專用的裝置。在海外不能使用。在海外使用這個裝置的話成 為火災和觸電的原因。 設備內不要進水和異物。 設備內不要進入水、針、夾子等異物。有可能導致火災和觸電。一旦進入異物, 請立即關閉電源,將電源插頭從插座上拔下來。不要自行拆卸,請與經銷商或維 護服務公司聯繫。...
  • Page 31: 使用電源及電源線注意事項

    Before Using 1-13 使用電源及電源線注意事項 WARNING 不要用濕手拿電源插頭。 不要用濕手插拔電源插頭。有觸電的危險。 不要把地線連接到煤氣管道上。 請勿將地線連接到煤氣管道上。有導致煤氣爆炸的危險。 CAUTION 不要插入未指定的插座。 電源請使用指定電壓及電源的壁式插座。使用未指定的電源會造成火災和漏電。 請避免使用延長線安裝設備。如果連接與本產品電源規格不相符的電線,會因過 熱而導致火災。 不要在一個插座上插接多個電源線。 插座如果超過額定電流,會因過熱而導致火災的危險。 不要只插入一半。 請將電源插頭直插到底部。如果插入一半會因接觸不良而發熱,造成火災。另外, 插入部如附著灰塵、水滴等,會因發熱導致火災。 不要使用未指定的電源線。 請使用下列規格的AC電源線。 此外,操作和連接電源線時請遵循以下注意事項。 不要拖拽電源線。 不要夾電源線。 不要彎折電源線。 不要使電源線靠近化學藥品。 不要扭曲電源線。 不要在電源線上載入物品。 不要捆綁電源線。 不要對電源線進行改造、加工、修復。 不要用固定器等固定電源線。 不要使用損傷的電源線。(損傷的電源線要立即更換為相同規格的電源線。更 換事宜請與經銷商或維護服務公司聯繫)...
  • Page 32 1-14 Before Using 3極點用的電源插座以外不使用。 被本裝置添加的電源編碼拿第3大頭針(earth pin)的3極點插頭被裝備。這個插 頭,只3極點用的電源插座能使用。使用那個以外的電源插座的話,有觸電的可能。 其他的裝置和用途不使用添加的電源編碼 添加的電源編碼作為目的被設計連接到本裝置,使用的事,那個安全性被確認。 請別絕對其他的裝置和用途使用。有成為火災和觸電的原因的可能。...
  • Page 33: 安裝,移動,保管及連接注意事項

    Before Using 1-15 安裝,移動,保管及連接注意事項 CAUTION 不要安裝或存放在未指定的場所。 不要將本設備放置在如下場所和本書未指定的場所,有導致火災的危險。 灰塵較多的場所 熱水器旁等濕氣較高的場所 陽光直射的場所 不平穩的場所 不要在腐蝕性環境中使用或存放設備。 不要在有腐蝕性氣體(如二氧化硫、氫化硫、氮、氫、氨或臭氧等)的環境中使 用或存放本產品。 不要將本產品安裝在灰塵較多或含有腐蝕性物質如氯化鈉或硫磺等的地方。 不要將本產品安裝在空氣中含有過量金屬碎末或傳導粒子的地方。 上述環境可能導致本產品腐蝕或短路,因而損壞產品,甚至引起火災。 對產品安裝或存放環境有任何疑問,請與經銷商或維修服務公司聯繫。...
  • Page 34 1-16 Before Using CAUTION 不要使用未指定的信號線。 使用NEC指定的信號線,並在確認連接設備和介面後進行連接。使用未指定信號 線或連接錯誤等會造成短路、導致火災。 信號線的操作和連接,須遵守以下注意事項: 不要使用任何損壞的信號線接頭。 不要踩踏信號線。 不要在信號線上載入物品。 信號線接鬆動時不要使用。 不要使用任何損壞的信號線。...
  • Page 35: 整理及操作內部設備時的注意事項

    Before Using 1-17 整理及操作內部設備時的注意事項 WARNING 不要自行拆卸、修理或改造本伺服器。 除本書記載的情況外,不要進行拆卸、修理、改造。否則,不但可能導致設備不 能進行正常運行,還有發生觸電和火災的危險。 不要看光碟機內部。 光碟機使用了雷射,請不要在電源打開的狀態下觀看內部或插入鏡子等。雷射射 射入眼睛有導致失明的危險(雷射肉眼看不見)。 不要擅自拆除鋰電池。 本產品內部安裝有鋰電池。請不要拆下電池。鋰電池靠近火或浸水均有可能發生 爆炸。 由於電池使用期限而導致設備不能正常運行時,不要自行拆卸、更換、充電等, 請與經銷商或維護服務公司聯繫。 清潔伺服器前請拔下電源插座。 整理或拆裝本設備內部的選購配置時,要切斷設備電源,並拔下電源插頭。即使 已關閉電源,但連接著電源線,接觸到任何內部設備也有觸電的危險。 另外,請經常拔下電源插頭,用乾布擦拭灰塵和附著物。有灰塵或水滴等附著時 會發熱,有導致火災的危險。 CAUTION 注意高溫 本產品關閉電源後,內置硬碟等內部設備仍然處於高溫狀態。請在充分冷卻之後 進行拆裝。 確認安裝完畢。 電源線和信號線、配件板要確實安裝妥當。 安裝不牢有可能引起接觸不良,可能造成冒煙和著火。...
  • Page 36: 操作注意事項

    1-18 Before Using CAUTION 請用保護蓋保護好未使用的介面。 請用保護蓋保護好未使用的電源線介面以防止短路或觸電。從內部設備上拔下電 源插頭時,用保護蓋蓋好介面,否則有導致火災或觸電的危險。 操作注意事項 CAUTION 不要在打雷時觸摸機器。 打雷時請拔下電源插頭。如來不及拔下電源插頭,請不要觸摸設備及線纜等,防 止發生火災或觸電。 不要讓寵物靠近。 寵物的排泄物和毛髮進入設備可能導致火災和觸電。 設備上不要放置物品。 物品倒下可能引起傷亡,破壞硬體或導致火災。 不要將光碟機托盤拉出放置。 防止托盤中進入灰塵引起運轉錯誤。同時防止因碰撞等造成托盤損傷。...
  • Page 37: 機架式伺服器的注意事項

    Before Using 1-19 機架式伺服器的注意事項 CAUTION 不要將設備安裝在未指定的機架上。 請將設備安裝在符合EIA標準的19英寸機架上。一定要將設備安裝在指定的機架上 才能使用。否則設備可能無法正常使用,並有可能損壞機器零部件或導致人身傷 害。關於合適的機架,請與您的經銷商聯繫。 請不要自行安裝本設備。 為了避免人身傷害,請不要自行將本機器安裝到機架上。應該由受過專業訓練的 維護人員來安裝。 <僅供維護人員閱讀> 安裝機器時不能將機器的所有重量由一個地方來承載。 為了分散重量,應該加裝固定器或者同時安裝兩個或更多的機架,否則機架可能 會傾倒導致人身傷害。 不要擅自組裝零部件。 將前門和托架安裝到機架上至少需要兩人共同完成,否則可能會因為零部件跌落 而導致損壞或者人身傷害。 不要從不牢固的機架中抽出設備。 在抽出設備之前請確認機架已經被穩固器或者通過抗震技術固定。 不要從機架抽出兩個或者兩個以上的設備。 同時抽出兩個或者兩個以上的設備可能導致機架傾倒。一次只能抽出一個設備。 不要裝配過多電線。 為了避免火災和設備損壞,請務必確保不要超過線路的額定負載。有關電力設備 的安裝和電線的更多資訊請聯繫電工或者當地的電力公司。 請小心不要夾住或碰傷手指。 將本機器安裝到機架上或者從機架上卸載的時候,請務必小心以免被滑軌劃傷手 指。 一個人不做搬送·設置 架的搬送·設置請以3人以上去。架倒下成為傷和周圍的破損的原因。特別有高度的 架(44U架等)對不穩定的狀態有根據穩定器等沒被固定的時候。必定以3人以上一 邊支撐架一邊請做搬送·設置。...
  • Page 38: Unpackaging

    Keep the accessories in a safe place. You will need them when you perform setup, addition of options, or replacement of failed components. To check NEC EXPRESSBUILDER components, see the attached list. Be sure to fill out and mail the software registration card that is shipped with the operating system.
  • Page 39: 確認箱子的內容的

    Before Using 1-21 確認箱子的內容的 本產品和附屬品進入著專用的捆包箱子。從箱子取出各自檢點。捆包箱子和有餘了的附屬品請最後一幕 關於附屬品本 保管。 關於附屬品本 產品的捆包箱子的其中,對實體以外種種的附屬品進入著。確認參照添加的構成品表全部齊(整) 的事,請各自檢查。萬一不足的如果有東西和損傷的東西,請與購買的銷售店聯繫。 附屬品因為到做安裝的時候和選擇的增設,本裝置出現故障了的時候必要最後一幕請保管。 關於附屬品的「EXPRESSBUILDER」的構成品,請參照包裝中有的構成品表。 操作系統添加的軟件登記卡,請所定事項記入之後,必定投進郵筒。 如果軟盤被添加,請採用軟盤的接應。同時,作為 master disc 最後一幕保管添加的軟盤,請 使用備份盤。 光碟機 附屬的軟盤再 ,有在使用方法上犯錯誤的話變更了顧客的系統環境的可能。如果關於 使用有不明的點,不做困難的操作請對購買的銷售店,或保守服務公司詢問。...
  • Page 40 1-22 Before Using (This page is intentionally left blank.)
  • Page 41: Chapter 2 About Operating System

    Chapter 2 About Operating System This chapter gives essential information on the Windows system supported by the server and how to install it.
  • Page 42: Installing Windows Server 2003 X64 Editions/Windows Server 2003

    2-2 About Operating System INSTALLING Windows Server 2003 x64 Editions/ Windows Server 2003 For installing an operating system on NEC Express5800/ft series, refer to the below description. IMPORTANT: The NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
  • Page 43 Drivers and services for achieving duplicated operation NEC ESMPRO Agent The Express Setup program is exclusively used for the NEC Express5800/ft series. To execute the setup program, simply select the item [Express Setup] from the menu displayed when starting the system through the provided “NEC EXPRESSBUILDER.”...
  • Page 44 2-4 About Operating System (This page is intentionally left blank.)
  • Page 45: Chapter 3 Installing Server

    Chapter 3 Installing Server This chapter describes requirements for using the product properly and safely, the setup procedures to make NEC Express5800/ft series ready for use, and how to connect peripherals.
  • Page 46: Installation

    INSTALLATION This section describes installation of NEC Express5800/ft series. Rack-mount Model You can mount NEC Express5800/ft series on a rack that conforms to the EIA standards. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
  • Page 47 Do not leave more than one device pulled out from the rack. Do not install excessive wiring. Do not install NEC Express5800/ft series in such places as listed below. If you locate racks or install the server in such places, the server may malfunction.
  • Page 48 3-4 Installing Server Place that is close to some equipment that causes power noises (e.g., sparks caused by power-on/off using a relay). If you must install the server close to such equipment, request your sales agent for separate power cabling or noise filter installation.
  • Page 49: Installing The Device To The Rack (N8140-74/92/93/94/98/99)

    When the operating temperatures of NEC Express5800/ft series (10 to 35°C) are exceeded, there is a risk of malfunction. You must take adequate precautions and measures for airflow inside the rack as well as in the room so that the internal temperature can be kept within this range during operation.
  • Page 50 3-6 Installing Server Checking the place to install ● Imprinted mark (2 Decide the place (height) to install. To keep imprinted marks for balance, install it as low as you can on the rack. 5Us) 4U (the height To install the rack, the height for 4U is required. for installing this device) Places to install...
  • Page 51 Installing Server 3-7 TIPS: Core nuts (8 pieces) are not included. Use the core nuts that are attached to the rack. If the rack has front and rear doors, read the instruction that comes with the rack, and open them. Install the brackets from the rear side of the rack.
  • Page 52 3-8 Installing Server Fix the core nuts to the front side of the rack. Attach them symmetrically (total: 8 core nuts). Core nuts (top of device) Bottom of device Core nuts Fix a core nut from inside of the rack. Hook either of the clips of the core nut to a square hole of the rack, and hook the other clip to a hole by a flat-blade screwdriver.
  • Page 53 Installing Server 3-9 Tentatively fasten the washers and plate Washers and plate screws (short) screws (short) to the 4 places on the front and back sides (total: 8) from the rear. Washers and plate screws (short) Fasten tightly the washers and round screws (long) to the 2 places on the left and right sides (total: 4) from the front.
  • Page 54 3-10 Installing Server Fasten tightly the 4 round screws on the back side and the 8 plate screws on the side panels (which you fastened tentatively). Panhead screws on the side panels Plate screws on the side panels Plate screws on the side panels Mount the CPU/IO module 0.
  • Page 55 Installing Server 3-11 Fasten the levers on the left and right sides with screws. 10. Mount the CPU/IO module 1 in the same way.
  • Page 56: Unmounting The Device From The Rack (N8140-74/92/93/94/98/99)

    3-12 Installing Server Unmounting the device from the rack (N8140-74/92/93/94/98/99) Follow the steps below and unmount the device from the rack. CAUTION Observe the following precautions to use the server safely. There is a risk of a burn, personal injury, or damage to physical assets. For details, see “Notes for Safe Handling“...
  • Page 57: Installing The Tower Conversion Kit (N8843-002)

    Installing Server 3-13 INSTALLING the Tower Conversion Kit (N8843-002) This section describes how to install the rack-mount model of NEC Express5800/ft series without using the dedicated rack. IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to install it.
  • Page 58 3-14 Installing Server Do not install NEC Express5800/ft series in such places as listed below. Otherwise, the server may malfunction. Place where temperatures change widely (near a heater, air conditioner, or refrigerator). Place that is subject to intense vibration. Place where corrosive gas (sodium chloride, sulfur dioxide, hydrogen sulfide, nitrogen dioxide, or ozone) is generated, or a place that is close to chemicals or exposed to chemicals.
  • Page 59 Installing Server 3-15 Steps to Install the Rack-mount Model to the Tower Conversion Kit Follow the procedure below to install the devices to the tower conversion kit. Open the front door of the tower conversion kit. If the door is locked, use the server-accessory key to unlock.
  • Page 60 3-16 Installing Server Fix the bracket with four washers and countersunk screws (long ones), two at the top and two at the bottom. Fix the bracket with 4 washers and countersunk screws. See the figure on the right for where to fix the screws (2 screws for the backside on the top, and 2 for the bottom of the tower conversion kit).
  • Page 61 Installing Server 3-17 Lock lever If it becomes rocked and cannot insert any further, push and keep the rock lever to the left as push the device further inside. Close the lever on the top and the bottom of the device. Fix the device to the bracket with clinchers.
  • Page 62: Connect Peripheral Devices To Nec Express5800/Ft Series

    To connect a third-party peripheral device or interface cable to the server, check with your sales agent to see if they are compatible with NEC Express5800/ft series. Some third-party devices may not be used with the server.
  • Page 63 Installing Server 3-19 IMPORTANT: Connection of optional devices In the case of standard configuration, you need to complete setup of the operating system before mounting optional PCI cards or hard disks that you purchased separately. If N8803-035 is mounted, be sure to connect cables to the FC array unit before going on to the next step.
  • Page 64 3-20 Installing Server Rotate the stopper clockwise, and insert the power cords to the AC inlets of the power unit. Connect the plug at the other end of the power cord to a wall outlet with parallel double-pole grounds provided or to an uninterruptible power supply (UPS).
  • Page 65: Chapter 4 Windows Setup

    Windows Setup 4-1 Chapter 4 Windows Setup This chapter describes procedures such as configuring OS Boot Monitoring function, setting dual LAN configuration, and setting dual disk configuration.
  • Page 66: Before Starting Setup

    Installing Windows Server 2003 Use NEC EXPRESSBUILDER to install/reinstall Windows Server 2003. “Express Setup” is the setup program that is specific to NEC Express5800/ft series. NEC EXPRESSBUILDER DVD, a server accessory, runs this setup program. Express Setup enables automatic install of Windows Server 2003 and other various utilities.
  • Page 67: Setup Flow

    SETUP FLOW This flow chart illustrates the flow of the setup Step 1 Start the OS reinstallation setup procedure procedures for the NEC Express5800/320Fd-MR. Step 2 Prepare the OS reinstallation setup Step 3 Disable OS Boot Monitoring Function Windows Server 2003 (Express Setup)
  • Page 68: Step 1: Procedure To Install And Reinstall Os

    OS for reinstallation, you must back up the important data in the data partition first and then start “Express Setup.” Do not apply service packs to NEC Express5800/ft series based on your judgment. If you want to apply service packs, contact your sales agent for the latest application and apply service packs to NEC Express5800/ft series.
  • Page 69 Windows Setup 4-5 Microsoft® Windows Server™ 2003 R2 32-bit Enterprise Edition Disk2 (One set consists of two disks.) Windows Server 2003 Service Pack CD-ROM It is recommended to apply the latest service pack supported by ft Server. User’s Guide (Setup) (this manual) User’s Guide IMPORTANT: About the latest release of ft Server Control Software and purchase of the latest...
  • Page 70: Size Of The Partition To Be Created

    4-6 Windows Setup Size of the Partition to be Created For Windows Server 2003 x64 Editions: The required minimum size of a partition to install the system can be obtained from the following formula: Size required for installation + paging file size + dump file size Size required for installation = 5,900MB (Windows Server 2003 R2) = size of memory mounted* ×...
  • Page 71 Windows Setup 4-7 The mounted memory size means the total of memory installed on a single CPU/IO TIPS: module. For example, if memory of 1GB is mounted, the required minimum partition size obtained from the above formula is as follows: 5,300MB + (1024MB ×...
  • Page 72: Step 2: Prepare For Express Setup

    Before starting Express Setup, be sure to do the following. You can set up properly only when you make those preparations. 2-1: Prepare NEC Express5800/ft series With the power of NEC Express5800/ft series off, follow the steps below: Prepare NEC Express5800/ft series. •...
  • Page 73 Execute the operation to be taken when AC power supply is turned off. When the AC power is off (The power cord is not plugged into the outlet) Connect the power cords to NEC Express5800/ft series in the following order: Connect the power cord to the AC inlet A connector.
  • Page 74: Step 3: Disable Os Boot Monitoring Function

    For details of operations for BIOS Setup Utility and parameters, see the separate volume of User’s Guide. Procedure for Changing BIOS settings Turn on the display and the peripheral equipment connected to the NEC Express5800/ft series. CHECK: If the power cords are connected to a power controller like a UPS, make sure that it is powered on.
  • Page 75 After a while, the “NEC” logo will appear on the screen. While the “NEC” logo is displayed on the screen, NEC Express5800/ft series performs a power-on self test (POST) to check itself. For details, see the separate volume of User’s Guide.
  • Page 76 4-12 Windows Setup When the message “Press <F2> to enter SETUP” or “Press <F2> to enter SETUP or Press <F12> to boot from Network” is displayed on the display screen, press F2. The BIOS Setup Utility “SETUP” starts and the Main menu is displayed on the screen. Example: ftServer Setup Main...
  • Page 77 Windows Setup 4-13 Move the cursor onto “Server” and select “Server.” The Server menu will be displayed: ftServer Setup Main Advanced Security Server Boot Exit Item Specific Help System Management Console Redirection Additional setup Event Log Configuration menu to view Monitoring Configuration server management features.
  • Page 78 4-14 Windows Setup Move the cursor onto “OS Boot Monitoring” and press Enter. Parameters will be displayed. Among the parameters, choose “Disabled” and press Enter. The current display of the configuration for OS Boot Monitoring will be changed to “Disabled.” ftServer Setup Main Advanced...
  • Page 79 Windows Setup 4-15 Press the Esc key to go back to the Server menu, and then move the cursor and select “Exit” to display the Exit menu. ftServer Setup Main Advanced Security Server Boot Exit Item Specific Help Exit Saving Changes Exit Discarding Changes Exit System Setup and Load Setup Defaults...
  • Page 80: Step 4A : Start Express Setup

    Step 4A : Start Express Setup Set up with the Express Setup functions of NEC EXPRESSBUILDER. “Express Setup” is a setup method for NEC Express5800 series that allows configuration of hardware internal parameters and status and installation of OS (Windows Server 2003) and various utilities in seamless manners by using “NEC EXPRESSBUILDER”...
  • Page 81: Flow Of Setup Procedures

    Windows Setup 4-17 Flow of Setup Procedures The following flow chart illustrates the setup procedures for Express Setup. Loading parameters (Step 2) Skip Next Select the operating system (Step 3) Next RAID configuration (Step 4) Next Windows Confirm Setting / Input (Step 5 to 10) Next Save parameters (Step 11) Next...
  • Page 82: Setup Procedures

    2. Insert the NEC EXPRESSBUILDER DVD into the optical disk drive of the server. 3. Press the RESET switch or press Ctrl, Alt, and Delete to reboot from the NEC EXPRESSBUILDER. (You may also turn off and then on again to reboot the server.)
  • Page 83 Windows Setup 4-19 5. [Load parameters] steps are displayed. [Load parameters] (1) Select [Do not load parameters]. (2) Click [Next]. NOTE: If a floppy disk drive is not connected, select this item. [When you load parameters] (1) Insert the floppy disk containing the parameters file.
  • Page 84 4-20 Windows Setup 7. Enter the setting of a logical drive. [Enter RAID settings] steps are displayed. Retain the default value, and click [Next]. 8. Specify the installing medium and the Windows system partition. [Specify medium / Partition] steps are displayed. Confirm the parameters, modify if necessary, and click [Next].
  • Page 85 Windows Setup 4-21 You cannot reinstall the system with the existing partition that is upgraded to Dynamic Disk remained. Do not select “Use existing partitions” at “Windows system drive settings.” 9. Enter the user information and client license mode. [Enter basic parameters] steps are displayed.
  • Page 86 4-22 Windows Setup 10. Enter the setting of the network protocol. [Enter Network Protocol] steps are displayed. Retain the default value, and click [Next]. 11. Enter the domain or workgroup name to be used. [Enter domain account] steps are displayed. Retain the default value, and click [Next].
  • Page 87 Windows Setup 4-23 13. Select the installing applications. [Select applications] steps are displayed. Retain the default value, and click [Next]. 14. Save the parameters. [Save parameters] steps are displayed. If you want to save the parameters, set free formatted floppy disk.
  • Page 88 [Perform] in [Start Express setup] step. 16. Remove NEC EXPRESSBUILDER DVD from the optical disk drive according to the message. If you proceed the setup y using setup parameter file, remove the floppy disk from the floppy disk drive.
  • Page 89: Step 4B: Manual Setup

    Select this procedure when the NEC Express5800 series is the only computer for creating Windows Server2003 x64 Edition OEM-Disk for EXPRESSBUILDER. If Windows Server 2003 x64 Editions operates on the NEC Express5800, you can also select [Create from the menu start by auto-run] described later.
  • Page 90 The procedure is as follows: Prepare one 3.5-inch floppy disk. Start the operating system. Insert the NEC EXPRESSBUILDER DVD into the optical disk drive. The menu launches. Click [Create drive disk (for Windows)], and select [OEM-Disk for Widows Server 2003 x64 Edition].
  • Page 91: Installing Windows

    After loading the backup CD-ROM DISC 1 or the Windows Server 2003 R2 x64 Edition DISC 1 into the optical disc drive, reset (Press <Ctrl> + <Alt> +<Del>), or power off to reboot the NEC Express5800 series. System launches from the CD-ROM, and NEC EXPRESSBUILDER starts. IMPORTANT: When a bootable OS is already installed on the HDD, press <Enter>...
  • Page 92 4-28 Windows Setup Press <S> key when the right message appears. The right message appears. Set Windows Server 2003 x64 Edition OEM-Disk for EXPRESSBUILDER floppy disk into the floppy disk drive, then press <Enter>. SCSI adapter list appears. Select [Stratus Virtual Disk Driver], then press <Enter>. Go back to the step 5 screen and press <Enter>.
  • Page 93 14. Follow the steps below to update the system. Do not input or output data during the update process. a) After logging on to the system as a user with the Administrative account, insert NEC EXPRESSBUILDER DVD into the drive of the server.
  • Page 94 After logging on to the system as a user with the Administrative account, insert the “NEC EXPRESSBUILDER” DVD-ROM into the DVD-ROM drive of the server. b) The menu screen starts up. Click [Setup software] and select [ft Server Control Software] on the menu.
  • Page 95: Changing Drive Letters

    “ft Server Control Software UPDATE CD-ROM” and apply the update. 16. For how to install NEC ESMPRO/ServerAgent, see “NEC ESMPRO Agent”(Page 5-3). IMPORTANT: Make sure that “System Update” is applied and that “ft Server Control Software” and “NEC ESMPRO Agent” are installed. Follow Step5. Changing Drive Letters...
  • Page 96 4-32 Windows Setup...
  • Page 97: Step 5: Windows Server 2003 Service Pack Installation

    The NEC Express5800/ft series builds a duplex LAN configuration by using “Stratus emb-EB 2-Port Gigabit Adapter” mounted as standard on the CPU/IO module and extended PCI slot “NEC MT Gigabit Adapter,” “NEC MF Gigabit Adapter,” and “Stratus U575 Dual Port Copper Gigabit Adapter.”...
  • Page 98 4-34 Windows Setup communicates on the network. Regarding the path redundancy, you need to construct the environment by using the spanning tree not only on the server side but also on the switch side. You need to set the priority of the switch so that the path through the primary adapter is available even when a switch on the path is broken and the path information is updated.
  • Page 99: Nec Express5800/Ft Series Duplication Rule

    Setup The following describes the procedure to set duplex LAN configuration. The procedure to set the duplex LAN configuration of the example 1 in “NEC Express5800/ft Series Duplication Rule” above is explained. To set the duplex LAN configuration, log on as “Administrator” or a member of the group “Administrators.”...
  • Page 100 4-36 Windows Setup Select one target network adapter, right-click on it and select [Properties] from the displayed menu to display the Properties window. Select the [Teaming] tab in the Properties window. Check the radio button of [Team with other adapters] and click [New Team…].
  • Page 101 Windows Setup 4-37 Enter the team name, and click [Next >]. Select the check boxes of the adapters you want to include to the team, and click [Next>]. Select “Adapter Fault Tolerance” or “Adaptive Load Balancing” or “Switch Fault Tolerance” as a team mode. (Usually select “Adapter Fault Tolerance.”) Click [Next >].
  • Page 102 4-38 Windows Setup Click [Finish]. Start a command prompt, and confirm the physical MAC address of the team adapter with ipconfig /all. Select the team adapter that has been set, right-click on it and select [Properties] from the menu displayed to display the Properties window.
  • Page 103 Windows Setup 4-39 Select the [Advanced] tab in the Properties window. Select [Locally Administered Address] from the [Settings] list box, and enter the MAC address of team adapter that you have checked in the [Value:] text box, and click [OK]. Set the probe setting disabled when a team of two adapters is configured.
  • Page 104: Step 7: Set Dual Disk Configuration

    4-40 Windows Setup Step 7: Set Dual Disk Configuration NEC Express5800/ft series secures data by setting dual disk configuration using “RDR (Rapid Disk Resync) function.” Be sure to make dual disk settings by referring to the procedure. IMPORTANT: • Set dual disk configuration by the RDR (Rapid Disk Resync) function. If you want to use other disk management tool (e.g.
  • Page 105 RDR can only be set on the basic disk inserted into the built-in slot of NEC Express5800/ft series. It cannot be set on the dynamic disk. For the disk on which RDR is set, use the products with the same serial number.
  • Page 106 4-42 Windows Setup Start RDR Utility by goint to [Start] - [All Programs] -[RDR] - [RDR Utility]. IMPORTANT: If the [Disk Condition] of the OS-installed disk(the slot 1 of the PCI module 0) says “Boot/Configured/Active/Imported,” you do not need to take the procedure 4 to 6. Proceed to the procedure 7.
  • Page 107 Windows Setup 4-43 IMPORTANT: If you set RDR on the disk that includes a system partition or a partition that cannot be unmounted, the message on the right is displayed. Click [Yes]. The system is restarted after 2 minutes. After it is restarted, perform the steps 7and later.
  • Page 108 4-44 Windows Setup Right-click the Slot 1 of the PCI module 1 from the left pane of RDR Utility, and then click [Add Physical Disk To RDR Virtual Disk]. Click [OK].
  • Page 109 Windows Setup 4-45 Check that disk synchronization has been started and the status of the DISK ACCESS LED and RDR Utility display changes as the following table. During synchronization DISK ACCESS RDR Utility Condition Status Synchronization Amber and Simplex source disk blinking Synchronization Amber and...
  • Page 110 4-46 Windows Setup Synchronization completed DISK ACCESS RDR Utility Condition Status Synchronization Green and Duplex source disk blinking Synchronization Green and Duplex destination disk blinking RDR Virtual Disk Duplex None IMPORTANT: - If you have created a new partition on the disk where RDR has been set and which is duplexed, the created partition area is automatically synchronized.
  • Page 111: Step 8: Update Software

    Windows Setup 4-47 Step 8: Update Software If you use ftServer Control Software UPDATE CD-ROM, see “Installing ftServer Control Software” (page 6-12) to update the software. When there are other update modules, apply them in this step.
  • Page 112: Step 9: Connect And Configure Options

    4-48 Windows Setup Step 9: Connect and Configure Options When there are optional PCI boards or peripheral devices to connect to the main unit, power off the main unit. Then, for connecting them, follow the instructions in “PCI board” in the separate volume of the User’s Guide and the manual of the devices.
  • Page 113: Step 10: Create Volume

    Windows Setup 4-49 Step 10: Create Volume For NEC Express5800/ft series, you need to perform mirroring for each disk by the RDR function. If you created a new partition or volume on the disk that has been set RDR and dual configuration, the area is mirrored automatically.
  • Page 114: Step 11: Set Network For Nec Esmpro Agent

    4-50 Windows Setup Step 11: Set Network for NEC ESMPRO Agent NEC ESMPRO Agent is required for continuous operation of the NEC Express5800/ft series. It is automatically installed when you reinstall Windows 2003. To operate NEC ESMPRO Agent, you need to set the SNMP.
  • Page 115 To allow NEC ESMPRO Agent to receive SNMP packets sent from NEC ESMPRO Manager, set the send community name in NEC ESMPRO Manager to be the same as that accepted by the SNMP Service in NEC ESMPRO Agent. Terminate the network setup.
  • Page 116: Step 12: Enable Os Boot Monitoring Function

    4-52 Windows Setup Step 12: Enable OS Boot Monitoring Function Enable the “OS Boot Monitoring” setting which has been switched at “OS Boot Monitoring” (page 4-8). Refer to “Step 3: Disable OS Boot Monitoring Function“ (page 4-8), change to “Enabled,” and set appropriate time (default is 10 min.).
  • Page 117: Step 13: Make Settings For Failure Management

    Windows Setup 4-53 Step 13: Make Settings for Failure Management Make the following settings beforehand to ensure quick recovery from failure. You will see the procedure for Windows Server 2003 here; however, you can take the same procedure for Windows Server x64 Editions as well. Set Memory Dump (Debug Information) This section explains the setting for collecting memory dump (debug information) in the server.
  • Page 118 [Complete memory dump], as [Complete memory dump is not displayed on the drop down menu. Specify a disk drive that has a free space of the memory size on the NEC Express5800/ft series +1MB or more.
  • Page 119 Windows Setup 4-55 + 12MB). If the memory is expanded to larger than 2GB, change Write Debugging Information to [Kernel memory dump] before expanding the memory. Size of the debugging information (memory dump) to be collected changes due to the memory increase. Verify how much free space on the hard disk that debugging information is to be written.
  • Page 120 4-56 Windows Setup Click [Settings] in the [Performance] box. The [Performance Options] window appears. Click the [Advanced] tab on the [Performance Options] window.
  • Page 121 Windows Setup 4-57 Click [Change] in the [Virtual memory] box. Change the value set for [Initial Size] in the [Paging file size for selected drive] box to the [Recommended] value or more, and then click [Set]. IMPORTANT: Be sure to create the file in the size more than [Recommended] value in the OS partition.
  • Page 122 4-58 Windows Setup Size of the Partition to be Created“ (page 4-6). To be prepared for failure, it is recommended to press the dump button to see if the memory dump can be collected normally beforehand. If the memory has been expanded, re-set the paging file according to the memory size.
  • Page 123: Set Dr. Watson

    Set Dr. Watson Dr. Watson of Windows Server 2003 is a debugger for application errors. When detecting an application error, Dr. Watson diagnoses the NEC Express5800/ft series, and records the diagnostic information (log). Take the following steps to collect diagnostic information: Click [Run...] from [Start].
  • Page 124: Install A Network Monitor

    4-60 Windows Setup Install a Network Monitor A network monitor is useful for examining the causes of network failures and taking the countermeasures. To use the network monitor, you need to restart the system after the installation. It is recommended to install the network monitor before a failure occurs. From the [Start] menu, select [Control Panel] and click [Add/Remove Windows Programs].
  • Page 125: Set Recovery Console

    Windows Setup 4-61 If a message is displayed asking you to insert “Windows Server 2003 R2A Enterprise Edition CD-ROM,” follow the instructions on the screen. Close the menu that appears by inserting the CD-ROM. To close the menu, click the [X] mark on the menu.
  • Page 126: Step 15: Back Up System Information

    Save the information after completing the system setup. Without the backup data, you will not be able to recover the information. You can save the information by the following process: Insert the “NEC EXPRESSBUILDER” DVD into the optical disk drive of the server, and restart the system. Select [Tool menu].
  • Page 127: Chapter 5 Procedures After Completion Of Installation

    Chapter 5 Procedures after Completion of Installation This chapter describes how you install management utilities, how you back up system information, and setup of PCs on the network. You may need to confirm these procedures while the system is running.
  • Page 128: Installing Management Utilities

    The provided “NEC EXPRESSBUILDER” DVD contains “NEC ESMPRO Agent” for monitoring NEC Express5800/ft series and “NEC ESMPRO Manager” for managing the NEC Express5800/ft series. Install and setup these utilities in the NEC Express5800/ft series or the computer (management PC) that manages the NEC Express5800/ft series.
  • Page 129: Nec Esmpro Agent

    Make sure that NEC ESMPRO Agent is installed because it is indispensable for continuous operation of NEC Express5800/ft series. To set details about NEC ESMPRO Agent, double-click the [NEC ESMPRO Agent] icon in the [Control Panel] dialog box. The properties dialog box appears for changing the settings.
  • Page 130 Windows Server 2003 SP1 Preparation before Setup Be sure to read the following description before system installation or setup. To operate NEC ESMPRO Agent, you need to make settings of TCP/IP and the SNMP of components associated with TCP/IP. TCP/IP Setting See the Help started from the Start menu for how to set TCP/IP.
  • Page 131 To receive trap from NEC ESMPRO Agent at the NEC ESMPRO Manager machine, both community names should be the same. 5. Click the [Add...] button in [Trap destinations]. After entering the IP address of the NEC ESMPRO Manager machine of the send destination in the [Host name, IP or IPX address] box, click the [Add] button.
  • Page 132 To allow NEC ESMPRO Agent to receive SNMP packets sent from NEC ESMPRO Manager, set the send community name in NEC ESMPRO Manager to be the same as that accepted by the SNMP Service in NEC ESMPRO Agent. 7. Terminate the network setup.
  • Page 133 Installation NEC ESMPRO Agent is automatically installed together with the installation or re-installation of the NEC Express5800/ft series. NEC ESMPRO Agent may be installed manually on the master control menu of NEC EXPRESSBUILDER as follows: Login to the system with user name “Administrator.”...
  • Page 134 [Add or Remove Programs] in Control Panel, and install the new version. The setup program determines the machine type automatically. IMPORTANT: If the setup program is unable to determine the machine model, the setup of NEC ESMPRO Agent will be stopped. Click the [Next] button.
  • Page 135 Procedures after Completion of Installation 5-9 Enter the path in which NEC ESMPRO Agent is installed and click the [Next] button. The NEC ESMPRO Agent module is installed below the ESM directory of the root partition in default. If no problem is found, click the [Next] button without any modification.
  • Page 136 [Start] button, [Setting], and [Control Panel] sequentially to open [Control Panel]. If you double-click the [NEC ESMPRO Agent] icon in [Control Panel], the property dialog box will appear. Modify the setting of each sheet in the dialog box to be fit to the used environment. The notes on setup and the necessary information are explained in “Supplement”...
  • Page 137 The error occurs by InstallShield if the uninstallation is executed with the setting changed, and the uninstallation fails. With using NEC EXPRESSBUILDER: Make the main menu of the NEC ESMPRO setup appear by referring to the section “Install” in this document. Click [NEC ESMPRO Agent].
  • Page 138: Nec Esmpro Manager

    Notify Monitor When a failing module in the server is to be replaced, NEC ESMPRO Manager enables logical module disconnection from the server and logical installation after module replacement. For the installation of NEC ESMPRO Manager and notes on the operation, see the separate volume...
  • Page 139: Confirming The Ft Server Control Software Version

    The following describes how to check the version of ft Server Control Software, which consists of various types of software for fault tolerance. Perform the procedure when you need to check the ft Server Control Software version of the current system before adding units or attachment to NEC Express5800/ft series.
  • Page 140: Applying Windows Service Pack

    Notes to apply the Windows Service Pack You should not apply service packs other than those listed in “Step 1; Things Required for Setup” of Chapter 4 “WINDOWS SETUP” (page 4-4) in User’s Guide (Setup) on NEC Express5800/ft series by yourself.
  • Page 141: Compressing A System Drive

    Before updating Windows modules by using the Windows Update function on NEC Express5800/ft series, make sure to read the description of each module. Contact NEC sales agent for information about the test status of security patch and QFE on NEC Express5800/ft series. It is strongly recommended to contact NEC sales agent when updating the operating system on NEC Express5800/ft series.
  • Page 142 5-16 Procedures after Completion of Installation (This page is intentionally left blank.)
  • Page 143: Chapter 6 Troubleshooting

    Chapter 6 Troubleshooting This chapter describes what to do when files needed to operate the OS are damaged and any trouble occurs on the product.
  • Page 144: System Repair

    6-2 Troubleshooting SYSTEM REPAIR If the system cannot be operated by some reason, use Recovery Console to restore the system. However, this method is only recommended to users or administrators who have good knowledge of the system. When you have restored a damaged file by using Recovery Console, always update the system as described later in this chapter.
  • Page 145 Troubleshooting 6-3 2. Environment variable “AllowRemovableMedia” setting IMPORTANT: This setting is made on the Windows Server 2003 Recovery Console when the Windows Server 2003 Recovery Console is in use. This should be set every time when the Recovery Console is started.
  • Page 146: Preparation

    FD : Floppy disk CD : CD-ROM Preparation You need a support disk, “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” to start up the Recovery Console. Have “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” ready before starting the Recovery Console.
  • Page 147: Starting Up Recovery Console

    Troubleshooting 6-5 If you have a computer that runs Windows Server 2003 or Windows 2000/XP/ Vista You can also create a “Windows Server 2003 OEM-DISK for NEC EXPRESSBUILDER” by the steps below: Prepare a 3.5-inch floppy disk. Insert the NEC EXPRESSBUILDER DVD into the drive of a computer that runs Windows Server 2003 or Windows XP/Vista.
  • Page 148 (b) When the CD-ROM is set, reset the system (press Ctrl + Alt + Delete) or press the power switch to power off and on to reboot the NEC Express5800/ft series. (c) When the following message appears, press any key to start up from the CD-ROM.
  • Page 149 Troubleshooting 6-7 (b) Set the OS-specific “OEM-DISK” and press Enter. (c) Select [Stratus Virtual Disk Driver] and then press Enter. The screen of (a) is displayed again. (d) Select [Stratus Embedded SAS Adapter] and then press Enter. Go back to the screen of the procedure (a), press S key and proceed to the procedure (d).
  • Page 150 6-8 Troubleshooting IMPORTANT: The message shown above does not appear when you have started up the Recovery Console installed on the system. Follow the messages on the screen to start up the Recovery Console. IMPORTANT: When you restored a damaged file using the Recovery Console, update the system described in the next section.
  • Page 151: Updating The System

    Troubleshooting 6-9 Updating the System IMPORTANT: NEC Express5800/ft series is a precision instrument. You should ask maintenance personnel to update the system. You will need to update the system after you repair the system using Recovery Console. IMPORTANT: Make sure to follow the steps below when you have restored the system by using Recovery Console.
  • Page 152 6-10 Troubleshooting Remove duplications of all the LANs for both onboard and option boards. When dual LAN is disabled, a setup of LAN will be deleted. Note down the setup information. Start Device Manager. Select the team adapter that you want to cancel duplication, and select [Properties] from the menu displayed by right-click, to display the Properties window.
  • Page 153 Follow the steps below to update the system. Do not input or output data during the update process. a) After logging on to the system as a user with the Administrative account, insert NEC EXPRESSBUILDER DVD into the drive of the server.
  • Page 154 6-12 Troubleshooting IMPORTANT: If the message, “Windows - FT Orphaning A disk that is part of a fault-tolerant volume can no longer be accessed” is displayed during the update process, an OS stop error may occur when restarting the OS. If an OS stop error occurs, Hold down the POWER switch, and turn off the system.
  • Page 155: Installing Ft Server Control Software

    After logging on to the system as a user with the Administrative account, insert the “NEC EXPRESSBUILDER” DVD-ROM into the DVD-ROM drive of the server. b) The menu screen starts up. Click [Setup software] and select [ft Server Control Software] on the menu.
  • Page 156 6-14 Troubleshooting rebooting starts by clicking [OK]. Change this screen to check the message, as the message can hide behind the screen. For using “ft Server Control Software UPDATE CD-ROM” to update ft Server Control Software: After installing the ft Server Control Software, follow the procedure on the setup card attached to the “ft Server Control Software UPDATE CD-ROM”...
  • Page 157: Troubleshooting

    Did you set the NEC EXPRESSBUILDER DVD during POST and restart the server? → If you do not set the NEC EXPRESSBUILDER DVD during POST and restart the server, an error message will appear or the OS will boot.
  • Page 158: Problems With Windows Setup

    → ft Server Control Software UPDATE CD-ROM is used to update ft Server Control Software; it may not be shipped with the equipment. (Not included if “NEC EXPRESSBUILDER” DVD contains the latest version of software programs at the time of shipment). For the latest release of ft Server Control Software and purchase of the latest version of its ft Server Control Software UPDATE CD-ROM, contact your sales agent.
  • Page 159 Troubleshooting 6-17 Windows can be operated after a setup but each module or PCI board is not duplicated. (Status LED 2 on the CPU/IO module does not light on green). Did you abort the installation during a setup such as by closing a window of the programs that are running? →...
  • Page 160: Problems With Express Setup

    Detach external HDD(s) and run the Express Setup again. Cannot configure the details of network adapter. → You cannot configure the details of network adapter during setup of NEC Express5800/ft servers. You can configure this after the startup of Windows.
  • Page 161: Problems With Nec Esmpro Setup

    [Service Being Deleted…] dialog box. Shutdown the system by using Task Manager or other operation. Then uninstall NEC ESMPRO Agent after the system is started completely. * For installation procedure and detailed explanations on NEC ESMPRO Manager, refer to the online document in the NEC EXPRESSBUILDER DVD.
  • Page 162: Problems With System Repair

    6-20 Troubleshooting Problems with System Repair “Press F6 if you need to install a third party SCSI or RAID driver…” was not displayed and there was no chance to enter when “When starting Recovery Console from Windows Server 2003 CD-ROM” was performed. Did you press any key when the message “Press any key to boot from CD”...
  • Page 163: Appendix A About Services

    Appendix A About Services Information on NEC Express5800/ft series is provided the web at NEC Express5800 Web ASIA PACIFIC http://www.nec.co.jp/express/...
  • Page 166 N8800-122F/132F, EXP320J NEC Express5800/320Fd-LR N8800-123F/133F, EXP320K NEC Express5800/320Fd-MR User's Guide (Setup) 4th Edition 10-2008 856-127506-102-D...

Table of Contents