5. MCR Command Specifications

5.1. Command details

ESC #1
MCR on command
ASCII:
ESC
Hexadecimal: 1B
Description
 Turns on MCR. Does nothing if it is already on.
 Definitions of {n1} through {n3}
{n1}:
Set read/response mode
00h:
Continuous reading mode
01h:
Single reading mode (Reading ends even if it failed)
*Does nothing if none of the above
{n2}:
Timeout setting (seconds, 1 (min.) to 255 (max.)); 0 (00h) indicates no timeout.
{n3}:
Read track setting
*7 (07h) if other than 1 through 7
ESC #0
MCR off command
ASCII:
ESC
Hexadecimal: 1B
Description
 Turns off MCR. Does nothing if it is already off.
#
1
{n1}
{n2}
23
31
{n1}
{n2}
{n3}
1 (01h)
2 (02h)
3 (03h)
4 (04h)
5 (05h)
6 (06h)
7 (07h)
#
0
23
30
- 31 -
{n3}
{n3}
Read track
Track3
Track2
-
-
-
-
-
-
5. MCR Command Specifications