Honeywell PRESTIGE THX9321 System Installation Manual page 27

Iaq and rf eim
Hide thumbs Also See for PRESTIGE THX9321:
Table of Contents

Advertisement

Specifications & replacement parts
Operating Ambient Temperature
Thermostat: 32 to 120° F (0 to 48.9° C)
Portable Comfort Control: 32 to 120° F (0 to 48.9° C)
Wireless Outdoor Sensor: -40 to 140° F (-40 to 60° C)
Wireless Indoor Sensor: 0 to 120° F (-17.8 to 48.9° C)
– For Optimal Battery Life: 35 to 114° F (1.7 to 45.6° C)
Equipment Interface Module: -40 to 165° F (-40 to 73.9° C)
Return Air Sensor: 0 to 200° F (-17.8 to 93.3° C)
Discharge Air Sensor: 0 to 200° F (-17.8 to 93.3° C)
RedLINK Internet Gateway: -40 to 165° F (-40 to 73.9° C)
Operating Relative Humidity
Thermostat: 5% to 90% (non-condensing)
Portable Comfort Control: 5% to 90% (non-condensing)
Wireless Outdoor Sensor: 0% to 100% (non-condensing)
Wireless Indoor Sensor: 5% to 90% (non-condensing)
Equipment Interface Module: 5% to 95% (non-condensing)
RedLINK Internet Gateway: 5% to 95% (non-condensing)
Physical Dimensions (height, width, depth)
Thermostat: 3-7/8 x 6-13/16 x 1-7/16 inches (99 x 173 mm x 36 mm)
Equipment Interface Module: 9-5/16 x 4-13/16 x 1-19/32 inches (91 x 147 x 42 mm)
Wireless Outdoor Sensor: 5 x 3-1/2 x 1-11/16 inches (127 x 89 x 43 mm)
Wireless Indoor Sensor: 2-7/8 x 1-7/8 x 15/16 inches (74 x 48 x 24 mm)
Portable Comfort Control: 6-1/4 x 3-1/8 x 1-5/8 inches (158 x 80 x 38 mm)
RedLINK Internet Gateway: 6 x 4-7/8 x 2-1/2 inches (152 x 124 x 64 mm)
Electrical Ratings
Terminal
W - O/B
Y (cooling)
G (fan)
W2 - Aux 1 (heating)
Y2 (cooling)
W3 - Aux 2
A-L/A (Output)
U1, U1
U2, U2
U3, U3
S1, S1
S2, S2
Accessories & Replacement Parts
Item
RedLINK Internet Gateway
Wireless Remote (coming soon)
Vent Boost Remote (coming soon)
Portable Comfort Control
Wireless Outdoor Sensor
Wireless Indoor Sensor
Wired Outdoor Sensor
Wired Indoor Sensor
Wired Flush-mount Indoor Sensor 20k ohm NTC
Wired Wall-mount Indoor Sensor 20k ohm NTC
Wired Wall-mount Indoor Sensor 10k ohm NTC
Discharge or Return Air Sensor 10k ohm NTC
Discharge or Return Air Sensor 20k ohm NTC
Discharge or Return Air Sensor 20k ohm NTC
Cover Plate (covers marks left by old thermostats)
Battery Pack (For demo use only)
Wire Saver Module
69-2490_B.indd 27
THX9321/9421 Prestige
Voltage (50/60 Hz)
18 to 30 VAC and 750 mVDC 1.00A
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
18 to 30 VAC
30 VAC max.
30 VAC max.
30 VAC max.
30 VAC max.
30 VAC max.
Part Number
THM6000R1002
REM1000R1003
HVC20A1000
REM5000R1001
C7089R1013
C7189R1004
C7089U1006
C7189U1005
C7772
TR21
TR21-A
C7735A1000
C7041
C7770A1006
50028399-001
THP1000A1007
THP9045A1023
27
IAQ and RF EIM
®
Max. Current Rating
1.00A
0.50A
0.60A
0.60A
1.00A
1.00A
0.50A
0.50A
0.50A
0.50A
0.50A
69-2490—03
7/13/2011 1:42:02 PM