Honeywell 203365A Installation Manual
Honeywell 203365A Installation Manual

Honeywell 203365A Installation Manual

Vac to 220/240 vac conversion kit for electronic air cleaners

Advertisement

Quick Links

203365A 120 Vac to 220/240 Vac
The 203365A Conversion Kit changes the 120 Vac,
60 Hz to 220/240 Vac, 50/60 Hz. The kit includes a trans-
former and two screws. The line cord on the air cleaner
must be changed to conduit to complete the conversion.
NOTE: The air cleaner can be completely isolated from
the electrical circuit of the HVAC system unless re-
quired by local code to use same circuit. Any convenient
house circuit can power the air cleaner, regardless of
electrical rating of HVAC system.
WHEN INSTALLING THIS PRODUCT...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous condi-
tion.
Fig. 1—Remove power box.
2
1

Electronic Air Cleaners

Application
Installation
J. H. • Rev. 8-93 • ©Honeywell Inc. 1993 • Form Number 69-0769—1
1
Conversion Kit For
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
operation as provided in these instructions.
MOUNT TRANSFORMER
1. Open access door.
2. Remove and retain the two screws from the front of
the power box.
3. Lift and remove the power box.
4. Remove and retain the two screws from the sides of
the power box. See Fig. 1.
5. Remove the power box cover.
6. Place the transformer on the mounting holes. See
Fig. 2.
3
4
M6168
69-0769—1

Advertisement

loading

Summary of Contents for Honeywell 203365A

  • Page 1: Electronic Air Cleaners

    Fig. 2. 1. Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condi- tion. Fig. 1—Remove power box. M6168 J. H. • Rev. 8-93 • ©Honeywell Inc. 1993 • Form Number 69-0769—1 69-0769—1...
  • Page 2 NOTE: Be sure the transformer terminals are located on the side away from the power supply. See Fig. 2. Fig. 2—Mount and wire transformer. 7. Use the two provided screws to secure the trans- former to the power box. WIRE TRANSFORMER TO POWER SUPPLY (See Fig.
  • Page 3 Fig. 3—Internal schematic for electronic air cleaner with 203365A Conversion Kit. BLACK COLLECTOR TEST RED IONIZER BUTTON CONTACT BOARD BLACK BLACK POWER SUPPLY BLACK ORANGE GREEN GRAY BROWN VIOLET TERMINAL STRIP BLACK FRONT BACK BLACK BLACK W8600E WALL PANEL BLACK...
  • Page 4: Electrical Troubleshooting

    Checkout TOOLS AND EQUIPMENT Troubleshooting the electronic air cleaner requires: • Needle nose pliers for stringing ionizer wires and WARNING inserting edge connectors. • Test meter. ELECTRIC SHOCK HAZARD. CAN CAUSE PERSONAL INJURY OR NEON LIGHT (On Power Box) EQUIPMENT DAMAGE. The neon light is powered through the power supply and The following procedures expose hazardous live is on when the power supply output voltage is normal.
  • Page 5 Fig. 4—Troubleshooting air cleaners with solid-state performance indicator. START TO USE THIS CHART: MAKE SURE ELECTRONIC FOLLOW THE STEPS IN ORDER, DO NOT SKIP AROUND. CELL(S) ARE CLEAN, DRY EACH TIME YOU ISOLATE AND FIX A PROBLEM, AND PROPERLY INSTALLED. GO BACK TO START.
  • Page 6 Home and Building Control Home and Building Control Helping You Control Your World Honeywell Inc. Honeywell Limited—Honeywell Limitée 1985 Douglas Drive North 740 Ellesmere Road Golden Valley, MN 55422 Scarborough, Ontario M1P 2V9 QUALITY IS KEY Printed in U.S.A.