Honeywell L6064A Product Data

Universal two speed fan and limit controllers

Advertisement

Available languages

Available languages

Quick Links

L6064A
Universal Two Speed Fan and Limit Controllers

APPLICATION

These combination warm air fan and limit controllers
are suitable for all types of forced air heating systems.
The controllers have 2 switches with 3 individually ad-
justable set points. One switch opens the limit circuit if
the plenum temperature exceeds the preset safety limit;
most models reset automatically. The other switch
changes fan speeds. On all the L6064 the fan speed is
switched from low to high and vice versa according to
the plenum temperature. The fan speed is switched to
low if the plenum temperature falls below the fan off set
point. All the L6064 models are intended for use with
conventional warm air systems.
All models may be used as limit controls by wiring only
the limit side.
Limit controls are suitable for line voltage, low volt-
age, or millivoltage circuits.

INSTALLATION

When installing this product...
1. Read these instructions carefully. Failure to follow
them could damage the product or cause a hazardous
condition.
2. Check the ratings given in the instructions and on
the product to make sure the product is suitable for your
application.
3. Installer must be a trained, experienced service
technician.
4. After installation is complete, check out product
Operation as provided in these instructions.
Follow furnace or burner manufacturer's instruc-
tions, if available. Do not exceed the ratings and limi-
tations given in this section.

ELECTRICAL RATINGS:

NOTE: The electrical rating is at maximum case tem-
perature of 88
O
C (190
lating material, or a mounting bracket when mounting
surface temperature exceeds 88
Full Load (Amps)
Locked Rotor
(Amps)
Max. Amp.
Pilot Duty: 2 A at 24 Vac; 0.25 to 12 Vdc. (Limit)
Maximum Combined Connected Load: 2000 VA. ac. Load capacity at terminal points must not exceed the rated
capacity of connected wire at its rated insulation temperature. 75
O
F). Use high temperature insu-
O
C (190
O
F).
120 Vac
FAN LOW
FAN HIGH
6
14
84
CAUTION
!
1. Disconnect power supply before beginning in-
stallation to prevent electrical shock or equipment
damage.
2. When connecting cable or conduit to control,
avoid straining the control case.
LOCATION
If this is a replacement installation, locate the
L6064 in the same location as the control being re-
placed. The L6064 sensing tube length should be
the same as the old control. If this is a new installa-
tion, the element should be installed only by a
trained, experienced service technician according
to the furnace manufacturer's instructions. The ele-
ment must not touch any internal part of the furnace.
MOUNTING
The device may be mounted as follows:
All models -- Surface or Bracket.
SURFACE MOUNTING
Hole in plenum should be just large enough to
accommodate the 20 mm (3/4 in.) diameter element
tube.
1. Remove cover by squeezing sides and pulling
off. Insert element in plenum and mark location of
mounting holes. Make sure the case is snug against
the plenum before marking the mounting holes.
2. Punch or drill holes for mounting screws.
3. Place insulation between plenum and case if
necessary, or use a mounting bracket.
4. Fasten controller securely with mounting
screws.
90
O
C field wiring may be required.
NOTE: For applications under DIN or BEAB juris-
diction ambient temperatures must not exceed
O
O
70
C (158
F).
240 Vac
LIMIT
FAN LOW
FAN HIGH
8
3
48
O
C minimum field wiring is required.

PRODUCT DATA

24 Vac
LIMIT
FAN
4
7
24
42
LIMIT
2

Advertisement

Table of Contents
loading

Summary of Contents for Honeywell L6064A

  • Page 1 L6064A Universal Two Speed Fan and Limit Controllers PRODUCT DATA APPLICATION CAUTION These combination warm air fan and limit controllers are suitable for all types of forced air heating systems. 1. Disconnect power supply before beginning in- The controllers have 2 switches with 3 individually ad- stallation to prevent electrical shock or equipment justable set points.
  • Page 2 WIRING Disconnect power supply before beginning installation to prevent electrical shock and equipment damage. FURNACE All wiring must comply with local electrical codes and PLENUM ordinances. See Fig. 5 for typical hookups. 1. To remove the slotted knockouts, bend down and break off with a long hose pliers.
  • Page 3 L6064 L6064 LIMIT SIDE SIDE LIMIT SIDE SIDE (HOT) 120V LOW SPEED LOW SPEED (HOT) HIGH SPEED HIGH SPEED ADD DISCONNECT MEANS AND OVERLOAD PROTECTION AS REQUIRED TO CONTROL LOW VOLTAGE EQUIPMENT Fig. 5 - A: Limit in low voltage circuit. B: Limit in line voltage circuit.
  • Page 4 Automation and Control Solutions Honeywell International Inc. Honeywell Limited 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN, 55422 Toronto, ON, M1V 4Z9 www.honeywell.com/building/components 08/06 RB © Honeywell 2006 Printed in Canada 95C-10617B 1...
  • Page 6 BORNE-PRESSION VERROUILLABLE PROTØGE-FILS PRISE FEMELLE POUR LE RACCORDEMENT D’UNE BORNE ¸ COSSE M LE DE ORIFICE 6,4 MM (1/4 PO) POUR FIL POUR RETIRER UN CONDUCTEUR FAN LIMIT BORNES- STANDARD, PRESSION POUR POUSSER AVEC UN CONDUCTEURS TOURNE-VIS ET STANDARDS TIRER LE FIL LOAD LINE LIMIT...
  • Page 7 VENT C T VENT LIMITEUR LIMITEUR DO NOT ROTATE - HOLD DIAL WHEN SETTING POINTERS...