ELE,CTRlC DRYER MODELS
&
.
.
+I
3"
I+
P
PLAIN ENDS
(30 AMPERES)
PLAIN-END
FIELD WIRING
FIGURE
14
NOTE:
The terminal
connections
at the dryer ter-
minal
block
are suitable
for connection
of #lO
copper wire only. To install plain-end
field wire:
1. Strip outer covering
back 3 inches from the end
exposing the 3 wires.
2. Strip the insulation
back 1 inch from the end of
each wire. Form the bare wire into a "U"
shaped
hook.
3. Loosen, do not remove, the center silver colored
screw of the terminal
block.
4. Slide the end of the neutral
(white
or center)
wire under the screw head with the open side of
the hook on the right. Squeeze the wire together
to form a loop.
5. Tighten
the screw firmly.
6. Connect
the
remaining
2 wires
to the outer
screws the same way. Tighten
screws firmly.
7. Tighten
strain relief.
INSTALLATION
PROCEDURE
1. Open the dryer, door and remove the shipping
tape holding
the dryer drum to the cabinet.
.2. Remove all literature
and installation
parts from
the dryer drum.
3. Block up the front of the appliance
about four
inches and install leveling
feet in the front corners.
These feet should
extend
approximately
one inch.
Remove the block and repeat the procedure
at the
rear of appliance.
For mobile
home
installations
all floor
mounted
dryers must be fastened
to the floor during
transit
using Kit No. 346765. The dryer does not need to be
fastened
to the floor while the mobile
home is not
in transit.
4. Refer to the Exhaust
System
Requirements
in
these instructions.
NOTE: For mobile home installations
the dryer must
be exhausted
to the outside. If the dryer is exhausted
through
the floor and the area under
the mobile
home
is enclosed,
it is recommended
that the
exhaust
system
terminate
outside
the enclosure.
Extension
beyond
the enclosure
will prevent
the
accumulation
of lint and moisture
under the mobile
home.
5. Move the applrdnce
into its permanent
position.
Level appliance
from front to back and from side to
side by adjusting
the leveling
feet.
INSTRUCTIONS
FOR RECESSED
OR CLOSET INSTALLATIONS
The
following
installation
spacings and door
air
openings
for the dryer are possible when installed
and exhausted
as noted.
(Spacing as indicated
is in
inches and is minimum
allowable.
For ease of in-
stallation
and service, additional
spacing should be
considered.)
CLOSET
FRONT VIEW
SIDE VIEW
FRONT VIEW
(DOOR NOT
SHOWN1
FIGURE
15
TO PREVENT
LARGE
AMOUNTS
OF LINTAND
MOISTURE
FROM
ACCUMULATING
AND
TO
MAINTAIN
DRYING
EFFICIENCY,
THIS
MA-
CHINE
MUST BE EXHAUSTED
OUTDOORS.
MINIMUM
INSTALLATION
SPACINGS
-~I
11
Unobstructed
air openings
required
for laundry
equipment
when door is installed.
*Shelf or cabinet is not permitted
above dryer when
non-exhausted.
**Louvered
door
with
equivalent
air openings
is
acceptable.
***'ID"
Dimension
must be measured from dryer
cabinet rear panel'.
Companion
appliancespacings
should be considered.
NOTE:
No other
fuel burning
appliance
may be
installed
in the same closet.