Direct Connect Method - RIDGID NaviTrack 10 Operator's Manual

Pipe and cable line transmitter
Table of Contents

Advertisement

Direct Connect Method

1. Attach the NaviTrack transmitter
to the line.
Remove the ground spike from the bottom of the unit
and insert it into the ground. Connect one of the
transmitter's leads to the grounding spike.
Figure 4: Attaching Lead to Ground Stake
2. Connect the other lead to the
target conductor.
Figure 5: Example of Connecting to a Line
www.navitrack.com
8
Figure 6: Alternative Connection to a Pipeline
Note: To increase safety it is recommended
that the ground lead be attached first. If there
was any high voltage running through the target
line then providing a ground would allow a means
of redirecting this current away from the transmitter
and operator. These are universal leads so either
may be used for the ground.
NEVER CONNECT TO LINES ENERGIZED WITH
A POTENTIALLY DANGEROUS ELECTRICAL
CURRENT. To increase safety, the ground lead
should be attached first. If there were an unknown
high voltage running through the target line, this
would allow a means of redirecting the current
away from the transmitter and operator.
ALWAYS HOOK UP LEADS FIRST BEFORE
POWERING THE UNIT ON TO AVOID SHOCK.
ALWAYS
TURN
DISCONNECTING LEADS.
Power the transmitter on by pressing the Power key.
3. Select a Frequency
This is done by pressing the key for the desired
frequency.
Ridge Tool Company
DANGER
UNIT
OFF
BEFORE
Elyria, Ohio
U.S.A

Advertisement

Table of Contents
loading

This manual is also suitable for:

Navitrack 10 watt

Table of Contents