Checking Battery Status: LEDs
The CS1000 has four battery indicator LEDs, two for
each battery, located just below the screen�
Figure 14 – Battery Indicator LEDs
When the unit is turned ON and there are batteries in
the battery docks, the LEDs on the CS1000 will reflect
the state of each battery as shown in Table 2�
LED Behavior
Green-Green
Green-Red
Red-Red
Blinking Red and
Beeps
Solid Red and
Continuous Tone
Slow Blink
Table 2: CS1000 Battery LED Indicators

External Power

NOTICE
The provided external power supply
is intended for indoor use only.
For plug in operation, a double insulated AC/DC power
supply is supplied to reduce wall outlet voltage to the
correct voltage for the CS1000�
1� To power the system using AC power with the
power cord, locate the power cord on the back of
the unit� Unhook the Velcro® strap and remove
the plug from its holder�
2� With dry hands, plug the power cord into an
approved outlet� If using an extension cord
ensure it is of adequate wire gauge� For cords of
25 feet a minimum gauge of 18 AWG is required�
For cords greater than 25 feet a minimum gauge
of 16 AWG is required�
3� Never power the unit from AC using the
power cord in a wet environment.
12
Meaning
Battery Full Charge.
Battery Partial Charge.
Battery Low.
Replace batteries immediately;
shutdown in one minute.
Dead batteries; shutdown in
five seconds.
External Power is in use.
Beeps when disconnected.
Sometimes you may need to move locations during a
job� If you are running your CS1000 using AC Power
but have a battery in the rear battery docks you can
unplug the CS1000 to move it without powering it OFF�
To remove all power to the unit, unplug the
power cord and remove the batteries from the
battery docks.
Operating Instructions
WARNING
Always wear eye protection to protect your eyes-
against dirt and other foreign objects.
When inspecting drains that might contain hazard-
ous chemicals or bacteria, wear appropriate protec-
tive equipment, such as latex gloves, goggles, face
shields or respirators, to prevent burns and infec-
tions.
Do not operate this equipment if operator or ma-
chine is standing in water. Operating machine while
in water increases the risk of electrical shock. Rub-
ber soled, non-slip shoes can help prevent slipping
and electric shock, especially on wet surfaces.
Follow operating instructions to reduce the risk of
injury from electrical shock and other causes.
Starting Up the CS1000
1� Connect the CS1000 to both a power source and
a SeeSnake camera inspection system�
2� Place the camera head into the inspection start
point, typically the pipe entrance�
3� Power the CS1000 and camera ON by doing
one of the following:
• Pressing the Power Key
keypad�
• Pressing the Power Key
screen�
• Pressing the Autolog Key
CS1000 keypad� This will power on the
Ridge Tool Company
on the CS1000
below the
on the