Download Print this page

Checkout; Cooling; Setting Time And Temperature - Honeywell T8000C Installation Instructions Manual

Programmable
Hide thumbs Also See for T8000C:

Advertisement

T8000C PROGRAMMABLE THERMOSTAT
To use the preprogrammed time and temperature (see
Table 3), press Hold to exit the programming mode.

Setting Time and Temperature

The T8000C is preprogrammed with the time and tem-
perature settings shown in Table 3. For instructions on
programming the thermostat refer to the Owner's Guide,
form no. 69-1143.
Table 3. Preprogrammed Time
and Temperature Settings.
Period
Time
Wake
6:00 AM
Leave
8:00 AM
Return
6:00 PM
Sleep
10:00 PM

CHECKOUT

Heating
1. Slide the SYSTEM switch to Heat and the FAN
switch to Auto.
2. Press and hold the
setting several degrees above the room tempera-
ture; the heating equipment should start. In conven-
tional systems, the system turns on the fan through
the use of a time delay relay or through a limit
control. When the fan operation (fuel) switch is in the
E position, the fan starts immediately.
3. Press the
key to lower the temperature setting
below the room temperature. Heating equipment
should stop.
Automation and Control Solutions
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
69-1433–1 G.H. Rev. 2-02
69-1433–1
Heat Setpoint Cool Setpoint
70°F (21°C)
78°F (26°C)
62°F (17°C)
85°F (29°C)
70°F (21°C)
78°F (27°C)
62°F (17°C)
82°F (28°C)
key to raise the temperature
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Printed in Mexico

Cooling

CAUTION
Damage To Compressor Possible.
Operating at too low of an outdoor temperature
may cause compressor damage.
Do not operate cooling if outdoor temperature is
below 50°F (10°C).
Allow compressor to remain off for five minutes
before restarting.
Refer to manufacturer's recommendations.
1. Slide the SYSTEM switch to Cool and the FAN
switch to Auto.
2. Press the
key to lower the temperature setting
several degrees below the room temperature; the
cooling equipment should start. The fan starts and
stops with the cooling equipment.
NOTE: If the cooling system does not start
immediately, remember that the thermostat
has a built-in minimum off-time of five
minutes to protect the compressor.
3. Press the
key to raise the temperature setting
above the room temperature. Cooling system should
shut down.
Fan
1. Slide the SYSTEM switch to Off and the FAN switch
to On. The fan should run continuously.
2. Slide the FAN switch to Auto. In heating, the fan is
controlled directly by the heating equipment and
may start a few minutes after the heating equipment
turns on (most systems). When the fan operation
(fuel) switch is in the E position, the fan starts and
stops with the heating equipment. In cooling, the fan
starts and stops with the cooling equipment.
Make certain all equipment responds correctly to the
thermostat.
6
www.honeywell.com/yourhome

Advertisement

loading