Serious injury could occur if you connect
the machine to power before completing the
setup process. DO NOT connect to power
until instructed later in this manual.
circuit requirements for g0548zp/
nominal voltage ........................................240v
cycle ..........................................................60 hz
plug/receptacle ............................. nema 6-15
g0548zp &
GROUNDED
g1029z2/z2p
6-15 RECEPTACLE
6-15 PLUG
figure 2. typical 6-15 plug and receptacle.
No adapter should be used with the
required plug. If the plug does not fit the
available receptacle, or the machine must
be reconnected for use on a different type
of circuit, the reconnection must be made
by a qualified electrician and comply with all
local codes and ordinances.
g0548zp, g1028z2, g1029z2-z2p (mfg. 12/12+)
g1028z2 circuit requirements for
120v operation (prewired)
cycle ..........................................................60 hz
GROUNDED
5-15 RECEPTACLE
5-15 PLUG
figure 3. typical 5-15 plug and receptacle.
SHOCK HAZARD!
Two-prong outlets do not meet the grounding
requirements for this machine. Do not modify
or use an adapter on the plug provided-if
it will not fit the outlet, have a qualified
electrician install the proper outlet with a
verified ground.
-11-