Installation Checklist - Kenmore 153.330501 Owner's Manual

Gas water heater
Hide thumbs Also See for 153.330501:
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE LIGHTING
THE PILOT:
• Check the gas lines for leaks.
_. Use a soapy water solution. DO NOT test for gas leaks
usin_a match or open flame.
h. Brush the soapy water solution on all gaspipes, joints and
fittings.
c. Check for bubblin_ soap. This means you have a leak.
Turn OFF gasanamake the necessaryrepairs.
d. Recheck for leaks.
e. Rinse offsoapy solution and wipe dry.
• Is the new temperature-pressure reliefvalve properly installed
and piped to an adequate drain?See _Temperature-Pressure
ReliefValve"section.
• Are the cold and hot water lines connected to the water
heater correctly? See "Water Piping" instructions in the
"Installation Instructions" section.
• Is the water heater completely filled with water? See "Filling"
instructions in the "Installation Instructions".
v
• Will a water leak damage anything? See the _Facts to
Cons derAbout the Location" section. -
• Is there proper clearance between _e water heater and any-
thing that might catch fire?See the Factsto Consider About
the Location section.
• Do you have adequate ventilation so that the water heater
wilt o_rate properly? See "Combustion Air and Ventilation"
inthe
Factsto Consider About the Location" section.
• Is the draft hood vent piping properly secured? See "Venting"
instructions in the "Installation Instructions" section.
• Is there proper deavance between the vent pipe and anything
that might catch on fire? See "Venting_ instructions in the
"I
"
"
"
"
nstallatzon Instructzons secuon.
VENT
PIPE TO
OUTDOORS
OR CHIMNEY
HOT
GAS SUPPLY
SHUTOFF
VALVE
_
TEE
_
_1
DRIP LEG
IMENT
TRAP)
t
PIPE CAP
m
(SEDIMENT
DRAFT
HOOD
COLD
UNION
SHUTOFF VALVE
'COLD
_
PRESSURE
RELIEF
VALVE
DISCHARGE
PIPE
Do not cap or plug)
DRAIN
VALVE
cowr)
_
1 6 INCH
AIR GAP
-3D
FLOOR DRAIN
• Is the vent pipe,_ropetly sloped and does the vent terminate
outdoors? See Venting" instructions in the _Installation
Instructions" section.
• Do you need to call your gas company to check the gas pipe
and its hookup?
CHECK
FOR LEAKS
Be sure to check all your gas pipes for leaks before lighting your
water heater. Use a soapy water solution, not a match oropen
flame. Check the factory gas fittings afxer pilot is lit and gas con-
trol knob is still in "PILOT" position. Then, check the fittings
when the main burner is turned "ON". Use a soapy water solu-
tion for this, too.
....
@!
mm
FOm
_
_
_
'-
I
t
I
MODEL
RATING
PLATE
16

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents