Installation Checklist - Kenmore POWER MISER 8 Owner's Manual

Hide thumbs Also See for POWER MISER 8:
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE
LIGHTING
THE
PILOT:
• Check the gas Enesfor leaks.
a. Use a soapy water solution. DO NOT test for gas teaks
usinga match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings.
c. Check for bubbling soap• This means you have a leak.
Turn "OFF" gas andmake the necessary repairs.
d. Recheckfor leaks.
e. Rinse offsoapy solution and wipe dry.
Is the new temperature-pressure
relief valve properly instaUed
and piped to an adequate
dram. See
Temperature-Pressure
ReliefVaflve"section.
• Are the _cold and hot water lines connected
to the water
heater
correctly?
See "Water
Piping"
instructions
in the
Installanon
Instrucnons
section.
• Is the water heater completely
filled with water? See "Filling:"
"nstruct ons m the Installation
Instructions"
sect on.
• Will
a water
leak dama
e an thin
_ See the "Facts
to
.g.
Y.
g.
Conmder About the Location
section.
• Is there proper clearance between the water heater and any-
thing that might catch fire? See the "Facts to Consider About
the Location" section.
Do you have adequate
ventilation
so that the water heater
will operate properly? See "Combustion
Air and Ventilation"
in the "Facts to Consider About the Location" section•
Is the draft hood vent piping properly secured? See "Venting"
instructions
in the "Installation
Instructions"
section.
Is there proper clearance between the vent pipe and anything
that might catch on fire? See "Venting"
instructions
in the
Installation
Instructions"
section.
Is the vent pipeproperly
sloped and does the vent terminate
outdoors?
See
Venting"
instructions
in the "Installation
Instructions
sectlon.
• Do you need to call your gas company
to check the gas pipe
and its hookup?
VENT PIPE TO
UNION
oV:i°° 'Y \ SHO FF
"+'- _J+'J+u.+
II, I
HOT
GAS SUPPLY
DRIP LEG --q_
(Sediment
trap) PIPE CAP
DRAFT HOOD
SHUTOFF VALVE
(_
_
TEMPERATURE.
PRESSURE
RELIEF VALVE
-- DISCHARGE
PIPE
(Do not cap or plug)
6" AIR GAP
DRAIN VALVE
/
FLOOR
DRAIN
UJL
I
I
I
,-
I
I
I
PJLt
W_
MODEL RATING PLATE
16