Installation Checklist - Kenmore 153.336451 Owner's Manual

Gas water heater
Table of Contents

Advertisement

Installation
Instructions
(cont'd)
Installation
Checklist
BEFORE LIGHTING
THE PILOT:
• Check the gas lines for leaks.
a. Use a soapy water solution. DO NOT test for gas leaks
usinga match or open flame.
b. Brush the soapy water solution on all gas pipes, joints and
fittings.
c. Check for bubbling soap. This means you have a leak.
Turn "OFF" gas andmake the necessary repairs.
d. Recheck for leaks.
e. Riuse off soapy solution and wipe dry.
• Is the new temperature-pressure relief valve properly installed
and piped to an adequate dram. See Temperature-Pressure
Relief Valve" section.
• Are the cold and hot water lines connected
to the water
heater
correctly?
See "Water
Piping"
instructions
in the
"Installation
Instructions"
section,
• Is the water heater completely filled with water. See Fdlmg
instructions in the "Installation Instructions" section.
• Will a water leak damage anything?
See the "Facts to
Consider About the Location" section.
ls there proper
clearance between
the water heater and any-
thing that might catch fire? See the "Facts to Consider
About
the Location"
section.
• Do you have adequate ventilation so that the water heater
will operate properly? See Combustion Air and Ventilation
in the Installation Instructions
section.
• Is the draft hood vent piping properly secur,e,d.See Venung
instructions in the 'Installation Instructions
sect'on•
• Is there proper clearance between the vent pipe and anything
that might catch on fir!! See Venting
instructions in the
"Installation Instructions
section.
• Is the vent pipe properly,sloped and does the vent terminate
outdoors? See "Venting
instructions
in the
Installation
Instructions
section.
Do you need to call your gas company to check the gas pipe
and its hookup?" section•
._-.(
HOT
VENT
PIPE TO
OUTDOORS
OR CHIMNEY
t
SHUTOFF
VALVE
COLD
UNION
GAS SUPPLY
SHUTOFF
VALVE
(SedimDRn I
DRAIN
VALVE
DRAFT
HOOD
TEMPERATURE-
PRESSURE
RELIEF VALVE
DISCHARGE
PIPE
not cap or plug)
" AIR GAP
IN
"_$_MAI_
_
WAllU K_AlSq"
€_1S _IAD
:-
I
I
I
MODEL RATING PLATE
16