ELECTRICAL
Wiring
Connections
[_WARNING] ]Fire haTAtl'd. Incorrect
voltage
can cause
a fire or seriously
damage
the motor
and voids the war-
ranty. The supply
voltage
must be within
+-10% of the
motor
nameplate
voltage.
NOTICE:
Dualwoltage
motors
are factory
wired
for
230 volts. If necessary,
reconnect
the motor
for 115
volts, as shown.
Do not alter the wiring
in single volt-
age motors.
Install, ground,
wire, and maintain
your pump
In com-
pliance
with the National
Electrical
Code (NEC) or the
Canadian
Electrical
Code
(CEC), as apphcable,
and
with all local codes
and ordinances
that apply. Consult
your local building
inspector
for code information.
Motor wires connect here.
-Power supply wires connect here.
230 Volt: Connect 2 hotwires (black and red
here and cap the wh te neutral)wire. It does
not matter which wire goes to which screw,
115 Volt: Connect one hot wire (black or red)
to one of these screws (it doesn't matter
which one). Connect the white (neutral) wire
to the other screw. Cap any remaining
black or red wires.
on the terminal
screws.
green (or bare copper) ground wire
to the green ground screw.
Figure 6 - Pressure switch wiring
3187 0398
Connection
Procedure
1. Connect
the ground
wire first as shown
in Figure 6.
The grotmd wire must be a solid copper
wire at least
as large as the power
supply wires.
2. There must be a solid metal connection
between
the
pressure
switch
and the motor
for motor
grounding
protection.
If the pressure
switch
is not connected
to the motor, connect
the green ground
screw in the
switch
to the green
ground
screw
under
the motor
end cover. Use a solid copper
wire at least as large
as the power
supply wires.
3. Connect
the ground
wire to a grounded
lead in a ser-
vice panel, to a metal underground
water
pipe, to a
metal well casing at least ten feet (3M) long, or to a
ground
electrode
provided
by the power
company
or the hydro authority.
4. Connect
the power
supply
wires
to the pressure
switch
as shown
in Figure 6.
5. Reinstall
the pressure
switch
cover.
TABLE
h WIRING
CHART
-
Recommended
Fusing
and Wiring
Data
Motor
Max,
Horse-
Load
power
Volts
Amperes
1/2
115/230
10.4/5.2
• Time delayedfuses are recommended insteadof fusesin an
Branch*
Fuse
Rating
Amps
15/15
Distance in Feet From Motor to Meter
0'
51'
101'
201'
201'
401'
to
to
to
to
to
to
50'
100'
200'
300'
400'
500'
Wire Size
14/14 I 14/14 I 10/14t10/14 I 6/14I 5/12
vmotor circuit.
6