Chapter 9 Operation and Maintenance
Message
CPU fan speed has exceeded the
warning threshold
CPU fan speed has exceeded the
critical threshold
System fan speed has exceeded the
warning threshold
System fan speed has exceeded the
critical threshold
Power supply fan speed has exceeded
the warning threshold
Power supply fan speed has exceeded
the critical threshold
System board voltage has exceeded
the critical threshold
System Event Log utilization has
exceeded the warning threshold.
Please save the System Event Log to a
different media and clear it
afterwards.
Warning!: The array is degraded.
Press [Ctrl] [A] to continue after insert
Floppy Disk.Warning!: The array is
degraded. Press [Ctrl] [A] to continue
after insert Floppy Disk.
258
table: List of POST Error Messages
A CPU fan is abnormal.
Check for objects hindering CPU fan rotation. If the message still
appears, contact an office listed in the "Contact Information" of the
"Start Guide".
A system fan is abnormal.
Check for objects hindering system fan rotation. If the message still
appears, contact an office listed in the "Contact Information" of the
"Start Guide".
A power supply unit fan is abnormal.
Check for objects hindering power supply unit fan rotation. If the
message still appears, contact an office listed in the "Contact
Information" of the "Start Guide".
Turn the server off and unplug the power cables from the server. Turn
the server back on. If the message still appears, the baseboard must be
replaced. Contact an office listed in the "Contact Information" of the
"Start Guide".
There is no space for system event logs.
Store or delete logs as necessary.
"9.3 System Event Log" (pg.267)
hard disk failure is detected.
"9.10.1 Hard disk failure is detected" (pg.287)"