18 gauge 5/8 - 2" length brad nailer
Table of Contents

Advertisement

Available languages

Available languages

Warranty ............................................
2
Safety Rules ...............................................
2
Operation
............................................
2-4
Maintenance
.....................................
4
Troubleshooting
......................................
5
Parts Illustration and List .................................
6-7
Espa,%l ...........................................
8-11
FULL ONEYEAR
WARRANTY
ON CRAFTSMAN
AIR-DRIVE
TOOLS
If this Craftsman air-drive tool falls due to a defect in material
or workmanship within one full year from the date of purchase,
return it to the nearest Sears Sewice Center in the United
States, and Sears will repair it free of charge.
If this air-drive tool is used for commercial purposes, this
warranty applies for only 90 days from the date of purchase
This warranty gives you specific legal rights and you may also
have other rights which vary from state to state.
Sears, Roebuck and Co, DepL 817WA, Hoffman Estates, 1L
60179
,,
Air tool operators and all others in work area shoutd
always wear safety goggles complying with United States
ANSI Z87 1 to prevent eye injury from fasteners and flying
debris when loading, operating or unloading this tool.
.
Never exceed operating pressure of 100 PSI.
°
Always keep hands and body away from the fastener dis-
charge area when air supply is connected to tool..
-
Always disconnect tool from air supply when servicing or
adjusting toot and when tool is not in use.
,,
Do not operate when contact trip is not in contact with
work.
,,
Never load the tool until you are ready to use it..
Never depress tool trigger when leading.
°
Always load with nose of tool pointing away from you and
others.
o Never point tool at yourself or others.
°
Never carry tool with trigger depressed.
_, Do not use oxygen, combustible gas or high pressure
compressed gas as the air supply for the tool.
o
Always use tool at safe distance from other people in work
area
o
Do not attempt to discharge fastener into hard or brittle
materials such as concrete, steel or tile.
.
Do not connect female quick-disconnect
coupling to tool
side of air line
o
Connect male, free-flow nipple to tool side of air line so
that tool is depressurized
when hose is disconnected,,
Do not use a hose swivel with thfs tool,
°
Use Sears recommended
fasteners only
DESCRIPTION
The Craftsman 18 Gauge Brad Nailer drives brads from %" t
2" long Die cast aluminum body with textured grip minimizes
operator fatigue_ Large capacity, side loading magazine with
positive, quick action latch makes loading easy Safety featur,
disables tool unless contact trip is pressed against workpiece
Tapered nosepiece provides operator with greater visibility foJ
precise fastener placement. Rigid nosepiece reduces jammin
The 18 Gauge Brad Nailer is excellent for molding, furniture
making, and picture framing.
SPECIFICATIONS
Capacity .....................................
110 brad nail
Nail size .......................
18 gauge (049" x .040"
Nail lengths ..............................................
% to 2
Operating pressure ...............................
60-100 RE
Air inlet ..................................
¼" N R1
Length
............................................
9
Height
..........................................
9%
Width ............................................
2½_
Weight
..........................................
2.6 lbs
BRAD
NAILS
18341 .........................
18 gauge brad nails, %" Ion!
18342 ...................
18 gauge brad nails, 1" Ion!
18343 ....................
t8 gauge brad nails, 1¼" ton_
18360 .............................
t 8 gauge brad nails, t½" tone
18361 ...................
18 gauge brad nails, t¾" Ion.(
18362 ....................
18 gauge brad nails, 2" Ion.(
AIR SUPPLY
LINE
Refer to Figure 1 (page 3)
.
The air tool operates on compressed
air at pressures frorf
60 to t00 PSI.
e
Never exceed maximum pressure
Minimum air requirements
for tool; Average working SCFb
3.2 at 90 PSI.
WARNING:
Keep hands and body away from discharge are_
of toot when connecting air supply Always disconnect tool
from air supply when servicing or adjusting tool and when toc
is not in use.
o
Air operated tools require clean, dry, lubricated com-
pressed air to ensure top performance,
low maintenance
and long life.
o
Dirt and abrasive materials present in atl air lines will dam
age tool O-rings, valves and cylinders..
o
Moisture will reduce tool performance
and life if net
removed from compressed air.
o
A flfter-regulatorqubricator
system is required and should be
located as close to tool as possible (see Figure 1, page 3)
A distance of less than 15 feet is recommended.
.
Keep air fitter clean A dirty filter will reduce the air p_essur{
to the tool causing a reduction in power and efficiency
The air supply system must be able to provide air pressure
of 60 to 100 pounds per square inch at tool.