Table 3-11
Data determined using p1910 for induction motors (stationary measurement)
Determined data (gamma)
r1912 identified stator resistance
r1913 rotor time constant identified
r1915 stator inductance identified
r1925 threshold voltage identified
r1927 rotor resistance identified
r1932 d inductance
r1934 q inductance identified
r1936 magnetizing inductance identified
r1973 encoder pulse number identified
Note:
The encoder pulse number is only determined with a very high degree of inaccuracy (p0407/p0408) and is only suitable for
making rough checks. The sign is negative if inversion is required (p0410.0).
-
Note:
If the encoder inversion is changed using MotID, fault F07993 is output, which refers to a possible change in the direction
of rotation and can only be acknowledged by p1910 = -2.
Table 3-12
Data determined using p1960 for induction motors (rotating measurement)
Determined data (gamma)
r1934 q inductance identified
r1935 q inductance identification current
Note:
The q inductance characteristic can be used as basis to manually determine the data for the current controller adaptation
(p0391, p0392 and p0393).
r1936 magnetizing inductance identified
r1948 magnetizing current identified
r1962 saturation characteristic magnetizing current
identified
r1963 saturation characteristic stator inductance
identified
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
Data that are accepted (p1910 = 1)
p0350 motor stator resistance, cold
+ p0352 cable resistance
r0384
motor rotor time constant/damping time constant, d axis
-
-
r0374 motor resistance cold (gamma)
p0354
r0377 motor leakage inductance, total (gamma)
p0353 motor series inductance
p0356 motor leakage inductance
p0358 motor leakage inductance
p1715 current controller P gain
p1717 current controller integral action time
-
r0382 motor main inductance, transformed (gamma)
p0360 motor main inductance
p1590 flux controller P gain
p1592 flux controller integral action time
-
p0410 encoder inversion actual value
Data that are accepted (p1960 = 1)
-
r0382 motor main inductance, transformed (gamma)
p0360 motor main inductance
p1590 flux controller P gain
p1592 flux controller integral action time
p0320 rated motor magnetizing current
-
-
Servo control
3.12 Motor data identification
95