F004; F001 - Hitachi L300P Series Quick Reference Manual

Three-phase input 200v class; three-phase input 400v class
Hide thumbs Also See for L300P Series:
Table of Contents

Advertisement

Parameter tables for user-settable functions follow these conventions:
• Some parameters have 2nd and 3rd motor equivalents, indicated by the
x2xx and x3xx parameter codes in the left-most column.
• Some parameters specify an option code. Where applicable, the
options codes will be in a bulleted list in the Name/Description
column.
• The default values apply to all models unless otherwise noted for each
parameter... –FE2 (Europe) / – FU2 (U.S.) / –FR (Japan).
• Some parameters cannot be edited during Run Mode, and certain
Software Lock settings (B031) can prohibit all edits. If in doubt, place
the inverter in Stop Mode or consult the inverter manual for details.
"F" Group: Main Profile Parameters
Func.
Code

F001

Output frequency setting
F002
Acceleration (1) time setting
F202
Acceleration (1) time setting, 2nd motor
F003
Deceleration (1) time setting
F203
Deceleration (1) time setting, 2nd motor

F004

Keypad Run key routing
• 00 Forward
Name / Description
• 01 Reverse
18
Default
Value
Set
–FE2/–FU2/
Value
–FR
0.00
30.0 / 60.0 /
30.0
30.0 / 60.0 /
30.0
30.0 / 60.0 /
30.0
30.0 / 60.0 /
30.0
00

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents