3.7 Y-CA Chassis Assy and Y-cutter Arm
3.7.1
Removing the Y-CA Chassis Assy
1. Remove the Y extension springs.
2. While the Roller holder is locked, remove the two Y-CA chassis screws.
3. Disengage the end of the Y-cutter arm from the Y sensor carriage by moving it in
direction A. Remove the Y-CA chassis assy.
Y-cutter arm
Y-CA chassis screws
Y-cutter arm
Roller holder
Y extension spring
Fig. 3.7-1
Removing the Y-CA Chassis Assy
Y sensor carriage
A
3-19