Chapter 5. Test Function - Sharp ER-A450T Service Manual

Service manual
Hide thumbs Also See for ER-A450T:
Table of Contents

Advertisement

CHAPTER 5. TEST FUNCTION

1. General
1) This diagnostic program has been developed for diagnosing ma-
chine functions in the field. The program is contained within the
ER-A450S.
The diagnostic program is stored in the external ROM which will
be executed by the CPU (H8/510) which requires the following
diagnostic operations:
a) Proper power supply voltages are mandatory for logic circuits
(+5V, VDD, POFF, +12.5V, +24V).
b) CPU input/output pins, CPU internal logic, CKDC8, MPCA7,
system bus and common ROM/RAM must be working prop-
erly.
2. Operational procedure
To start the diagnostic program, you must enter the following com-
mand.
SRV mode :
XXX
CA/AT
Test code
The key assignment must be properly set and the ROM and RAM
must be operating properly to go into this mode. This is necessary
because the control jumps to the program area in the SRV mode. A
master reset must be performed before operating the ECR for the first
time or the ER-03RA is installed. After any other options is installed, a
program reset is required. When the master reset or program reset is
performed, be sure to check the printout on the journal paper.
For Farther details on the MRS procedures, please refer to page 3-1.
3. Test command list
With the SRV mode and the following test code entry, the test start.
CODE
100
Display & Buzzer test
101
Key code & Cashier key test
102
R/J printer test
104
Keyboard test
105
Mode switch test
106
Printer sensor test
108
Calendar osilator test
109
SSP test
110
Drawer open sensor test (For standard drawer)
111
Drawer open sensor test (For remote drawer)
120
Standard RAM test
130
Standard ROM test
150
Printer dot pulse width adjustment
200
Option RAM test
501
RS-232 channel 1 Loop back check
550
RS-232 channel 8 Loop back check
DESCRIPTION
4. Test contents
[1] Display & Buzzer test
1) Key operation
100
CA/AT
2) Functional description
Displays the following message on the front and the rear display
boards.
1. 2. 3. 4. 5. 6. 7. 8. 9. 0.
A decimal point shifts from the lower number of digit by one digit (per
200m sec.).
Next, the display the following segments (for approx. 1 sec.).
8. 8. 8. 8. 8. 8. 8. 8. 8. 8.
The above two kinds of displays repeat continuously.
The buzzer sounds continuously during test.
3) Check items
a) The display must be correctly shown at each position.
b) The luminosity of displays must be uniform and even at each
position.
c) Abnormal buzzer sound indicate a problem.
4) Test termination
Press any key. The test terminates and the test No. and message is
printed
[2] Key code & Cashier key test
1) Key operation
101
CA/AT
2) Functional description
Key code, MRS switch state and Cashier code are displayed.
Cashier code
5 – 1
1 0 0
Key code
(Not used)

Hide quick links:

Advertisement

Table of Contents
loading