Error Codes

The error code buffer contains all errors detected since the last time the buffer
was erased. The buffer is written from left to right. When an error occurs that is
not yet in the error code buffer, it is displayed at the left side and all other errors
shift one position to the right.
How To Read The Error Buffer
You can read the error buffer in 3 ways:
On screen via the SDAM (if you have a picture). Examples:
o
ERROR: 0 0 0 0 0 : No errors detected
§
ERROR: 6 0 0 0 0 : Error code 6 is the last and only detected error
§
ERROR: 9 6 0 0 0 : Error code 6 was detected first and error code
§
9 is the last detected (newest) error
Via the blinking LED procedure (when you have no picture). See 'The
o
Blinking LED Procedure'.
Via ComPair.
o
How To Clear The Error Buffer
The error code buffer is cleared in the following cases:
By using the CLEAR command in the SDAM menu:
o
To enter SDAM, press the following key sequence on the remote
§
control transmitter: '062596' directly followed by the 'MENU' button
(do not allow the display to time out between entries while keying
the sequence).