1612-04: Pbx/Centrex Flash Timer; 1612-05: Flash Disconnect Timer; 1612-06: Ground Start Timer - NEC DSX Software Manual

Hide thumbs Also See for DSX:
Table of Contents

Advertisement

16xx-Timers
161x-COI (Analog Line) Timers
1612-Outgoing
Options
• 100-9999 mS
Default
• 800 mS

1612-04: PBX/Centrex Flash Timer

(Flash 1 Time)
Use this timer to set the Flash interval. When a user flashes a line (manually or in a Speed Dial number), the
system opens the line circuit for this interval. For accurate flash function, be sure to set this interval for com-
patibility with the connected telco or PBX/Centrex. If you set this interval too short, the telco may not
always register the flash. If too long, inadvertent disconnects may occur.
Features
• Flash (page 177)
• Speed Dial (page 315)
IntraMail Features
• Centrex Transfer (page 460)
Options
• 16-4080 mS
Default
• 800 mS

1612-05: Flash Disconnect Timer

(Flash 2 Time)
This option is currently not implemented.
Features
• None
IntraMail Features
• None
Options
• 16-4080 mS
Default
• 2496 mS

1612-06: Ground Start Timer

(Ground Time)
Before the system can start a ground start line, the telco's tip ground must be present for longer than this
interval. Set this interval for compatibility with the connected telco or PBX/Centrex. If you set this interval
too short, the system may inadvertently start a line it should not set up. If too long, the system may not start
lines that are functioning normally.
Features
• None
IntraMail Features
• None
Options
• 16-4080 mS
Default
• 800 mS