Checking the filter status
•
Touch the filter status check/reset
Note: The appliance goes back to normal display if no operations after 3 seconds�
4 Cleaning and maintenance
Note:
• Do not attempt to clean the particle sensor with a vacuum cleaner�
• Switch off the air purifier and unplug from the power socket before following action�
Cleaning the body of the air purifier
Use a soft, dry cloth to clean both the interior and exterior of the air
purifier and the air outlet�
Cleaning the particle sensor
Clean the particle sensor every 2 months for optimal functioning of the appliance�
1
Clean the particle sensor inlet and
outlet with a soft brush�
button to check the filter service life status�
Icon color
Blue
Blue-purple
Purple-red
Red
2
Clean the particle sensor with a damp
cotton swab� Dry all parts thoroughly with
a dry cotton swab�
Display (%)
16-100
9-15
4-8
0-3
EN